Properties of interdigital electrode arrays with different geometries

Abstract Interdigital array (IDA) microelectrodes have been fabricated by photolithographic and electron-beam lithographic techniques on silicon substrates. Thin-film noble metal electrodes have been deposited on a titanium-adhesion layer. The electrode width and space varied between 1 and 2 μm and between 300 nm and 1 μm, respectively. These IDA electrodes were applied to voltammetric and chronoamperometric measurements of reversible redox species using a home-build free programmable multipotentiostat. The multiple oxidation and reduction of these compounds result in an increased current generation, where the collection efficiencies and the signal amplification of reversible redox molecules have been determined. Both parameters are dependent on average diffusion length. The measurement conditions, such as ionic strength and buffer composition, influence the amplification rate. Time resolved redox recycling experiments showed that the diffusion equilibrium strongly depends on the distance between generator and collector electrode. A high redox recycling rate and collection efficiency of the IDA spacing in the nm-range enable electrochemical measurements to be performed more sensitive and faster than conventional measurements. These measuring principle is attractive to enhance the sensitivity of biosensor based microsystems.

[1]  Koichi Aoki,et al.  Quantitative analysis of reversible diffusion-controlled currents of redox soluble species at interdigitated array electrodes under steady-state conditions , 1988 .

[2]  D. Russell,et al.  Lanthanum hexaboride electron emitter for electron impact and electron-induced dissociation Fourier transform ion cyclotron resonance spectrometry , 1990 .

[3]  D. Pletcher,et al.  A microelectrode study of the mechanism and kinetics of the ferro/ferricyanide couple in aqueous media: The influence of the electrolyte and its concentration , 1993 .

[4]  J. Brewster,et al.  Microarray electrochemical flow detectors at high applied potentials and liquid chromatography with electrochemical detection of carbamate pesticides in river water , 1985 .

[5]  Hisao Tabei,et al.  Electrochemical behavior of reversible redox species at interdigitated array electrodes with different geometries: consideration of redox cycling and collection efficiency , 1990 .

[6]  Ulla Wollenberger,et al.  Interdigitated array microelectrodes for the determination of enzyme activities , 1994 .

[7]  A. Bond,et al.  Theory and experimental characterization of linear gold microelectrodes with submicrometer thickness , 1986 .

[8]  H. Matsuda Zur Theorie der Elektrolyse mit Zwei Eng Benachbarten Elektroden in Strömungsanordnungen. Allgemeine Formel für die Übertragungsausbeute , 1968 .

[9]  Kenji Yokoyama,et al.  Integration of enzyme-immobilized column with electrochemical flow cell using micromachining techniques for a glucose detection system , 1993 .

[10]  J. L. Anderson,et al.  Numerical simulation of convective diffusion at a microarray channel electrode , 1985 .

[11]  D. J. Harrison,et al.  Micromachining of capillary electrophoresis injectors and separators on glass chips and evaluation of flow at capillary intersections , 1994 .

[12]  R. Murray,et al.  An electrochemical time-of-flight experiment , 1987 .

[13]  Koichi Aoki,et al.  Theory of ultramicroelectrodes , 1993 .

[14]  Allen J. Bard,et al.  Digital Simulation of the Measured Electrochemical Response of Reversible Redox Couples at Microelectrode Arrays: Consequences Arising from Closely Spaced Ultramicroelectrodes , 1986 .

[15]  K. Aoki,et al.  Hydrodynamic voltammetry at channel electrodes: Part II. Theory of first-order kinetic collection efficiencies , 1977 .