Remote measurement of sulfur dioxide emissions using an ultraviolet light sensitive video system
暂无分享,去创建一个
Remote measurements of SO/sub 2/ emissions and plume velocities were made with a portable ultraviolet light-sensitive video system and compared with EPA in-stack compliance measurement methods. The instrument system measures the ultraviolet light absorption of SO/sub 2/ and movement of SO/sub 2/ fluctuations in the effluent plume and relates these measurements to the SO/sub 2/ concentration and velocity of the plume. Laboratory and field tests were conducted to establish the potential for using this technique for rapid surveillance of SO/sub 2/ emissions. The effects caused by submicron aerosols also were investigated. The field tests were performed on two occasions. On the first occasion, SO/sub 2/ and plume velocity measurements were made at a typical coal-fired power plant with flue gas desulfurization (FGD) controls (concentrations ranged from 80 to 365 ppm). The second occasion involved participation in an urban particulate modeling study, which resulted in routine SO/sub 2/ emission measurements performed at 12 industrial sites. The results of smoke generator and field tests indicate that the sulfur dioxide concentration of smoke stack emissions can be made with an accuracy less than +/-120 ppm (relative to the EPA stack test compliance method), provided the particulate opacity of the emissions is less thanmore » 22 percent. The velocity measurement feature of the instrument correlated poorly with the EPA compliance method for stack gas velocity.« less