Use of a charge-injection technique to improve performance of the Soft X-ray Imager aboard ASTRO-H

Abstract We are developing the Soft X-ray Imager (SXI), a charge-coupled device (CCD) camera system to be deployed onboard the ASTRO-H satellite. Using an engineering model system in which design specifications were the same as those of the flight model, we measured charge transfer inefficiency (CTI) and the effects of charge trailing. The CCD was irradiated with monochromatic X-rays produced by a radio isotope ( 55 Fe) and X-ray generator using alpha particles from 241 Am. We used four targets for the X-ray generator: (C 2 F 4 ) n , SiO 2 , Ti, and Ge. Since CTI degrades energy resolution, we adopted the charge-injection technique to the SXI. With this technique, injected charges fill traps, and subsequent signal charges are transferred with less loss of charge. However, the charge-injection technique can cause positional variations in gain on the CCD chip. Thus, we constructed a method for correcting CTI. We also evaluated the charge trailing effect and tested a method for correcting its effects. After applying these corrections to charge injection, variations in gain improved from 0.5% to 0.1% over the CCD chip, and the energy resolution (FWHM) improved from ~ 220 eV to ~ 180 eV at 5.9 keV.

[1]  Haruyoshi Katayama,et al.  Development of the analog ASIC for multi-channel readout X-ray CCD camera , 2011, 1102.2472.

[2]  J. A. Gregory,et al.  X-Ray Imaging Spectrometer (XIS) on Board Suzaku , 2007 .

[3]  Hiroshi Nakajima,et al.  Development of the x-ray CCD for SXI on board ASTRO-H , 2011, Optical Engineering + Applications.

[4]  Ryuichi Fujimoto,et al.  The X-Ray Observatory Suzaku , 2007 .

[5]  H. Uchiyama,et al.  Mitigating CCD radiation damage with charge injection: first flight results from Suzaku , 2007, SPIE Optical Engineering + Applications.

[6]  Hideyuki Mori,et al.  New CTI Correction Method for Spaced-Row Charge Injection of the Suzaku X-Ray Imaging Spectrometer , 2008, 0810.0873.

[7]  Yoshiharu Namba,et al.  The ASTRO-H X-ray Observatory , 2012, Other Conferences.

[8]  M. Bershady,et al.  SparsePak: A Formatted Fiber Field Unit for the WIYN Telescope Bench Spectrograph. I. Design, Construction, and Calibration , 2004, astro-ph/0403456.

[9]  C. E. Grant,et al.  Temperature dependence of charge transfer inefficiency in Chandra x-ray CCDs , 2006, SPIE Astronomical Telescopes + Instrumentation.

[10]  Beverly LaMarr,et al.  Performance of the Charge-Injection Capability of Suzaku XIS , 2007, 0705.1771.

[11]  Koji Mori,et al.  Proton radiation damage experiment on P-Channel CCD for an X-ray CCD camera onboard the ASTRO-H satellite , 2013, 1306.5400.

[12]  Martin J. L. Turner,et al.  In-orbit performance of the EPIC-MOS detectors on XMM-Newton , 2004, SPIE Astronomical Telescopes + Instrumentation.