Reliability of stabilised commercial dynamometers for measuring hip abduction strength: a pilot study

Background: Reliable quantification of hip abductor strength in a clinical setting is challenging. Objectives: To examine the intrarater and interrater reliability of three commonly used commercial dynamometers in the measurement of hip abduction. Methods: Supine gravity minimised measures of unilateral hip abduction strength were recorded in 10 women (mean (SD) age 23.5 (1.9) years) using three different commercially available dynameters. Measurements were repeated over a three day period with a different device used on each day. Results: Intrarater reliability ranged from 0.880 to 0.958 across the three devices, and measures of interrater reliability ranged from 0.899 to 0.948. Conclusion: Commercially available dynamometers can be used to quantify hip abduction strength with good to excellent reliability. A previously undescribed method of quantifying hip abduction strength in a clinical setting using readily available instrumentation is presented.

[1]  Richard W. Bohannon,et al.  Reliability and Validity of Measurements of Knee Extension Force Obtained by Hand‐held Dynamometry from Community Dwelling Elderly Women , 2001 .

[2]  T. Stitik,et al.  Portable dynamometer anchoring station for measuring strength of the hip extensors and abductors. , 2000, Archives of physical medicine and rehabilitation.

[3]  A. Vandervoort,et al.  Reliability of isometric hip abductor torques during examiner- and belt-resisted tests. , 1991, Journal of gerontology.

[4]  R W Bohannon,et al.  Test-retest reliability of hand-held dynamometry during a single session of strength assessment. , 1986, Physical therapy.

[5]  B. J. Norton,et al.  Clinical reliability of manual muscle testing. Middle trapezius and gluteus medius muscles. , 1987, Physical therapy.

[6]  W. C. Beasley,et al.  Influence of method on estimates of normal knee extensor force among normal and postpolio children. , 1956, The Physical therapy review.

[7]  JoAnne K. Gronley,et al.  Timing and relative intensity of hip extensor and abductor muscle action during level and stair ambulation. An EMG study. , 1983, Physical therapy.

[8]  Richard W. Bohannon,et al.  Interrater reliability of hand-held dynamometry. , 1987, Physical therapy.

[9]  J A Nicholas,et al.  The efficacy of manual assessment of muscle strength using a new device , 1982, The American journal of sports medicine.

[11]  D H Nielsen,et al.  Intrarater reliability of manual muscle testing and hand-held dynametric muscle testing. , 1987, Physical therapy.

[12]  J. Perry,et al.  The ability of male and female clinicians to effectively test knee extension strength using manual muscle testing. , 1997, The Journal of orthopaedic and sports physical therapy.

[13]  R W Bohannon,et al.  Normative values for isometric muscle force measurements obtained with hand-held dynamometers. , 1996, Physical therapy.

[14]  R. Patterson,et al.  Strength testing with a portable dynamometer: reliability for upper and lower extremities. , 1987, Archives of physical medicine and rehabilitation.

[15]  R W Bohannon,et al.  Reference values for extremity muscle strength obtained by hand-held dynamometry from adults aged 20 to 79 years. , 1997, Archives of physical medicine and rehabilitation.