Communicating malapposition of flow diverters assessed with optical coherence tomography correlates with delayed aneurysm occlusion
暂无分享,去创建一个
Jildaz Caroff | F. Clarençon | M. Gounis | M. Marosfoi | E. Langan | O. Brooks | A. Puri | T. Tamura | J. Caroff | Matthew J Gounis | Frédéric Clarençon | Ajit S Puri | Robert M King | Olivia W Brooks | Erin T Langan | Takamitsu Tamura | John Michael Wainwright | Miklós Marosfői | R. King | J. Wainwright | A. Puri | R. King
[1] Y. Jang,et al. The relationship between post-stent strut apposition and follow-up strut coverage assessed by a contour plot optical coherence tomography analysis. , 2014, JACC. Cardiovascular interventions.
[2] K. Lovblad,et al. A DSA-Based Method Using Contrast-Motion Estimation for the Assessment of the Intra-Aneurysmal Flow Changes Induced by Flow-Diverter Stents , 2013, American Journal of Neuroradiology.
[3] B. Nemes,et al. Contrast injection via the central artery of the left ear in rabbits: a new technique to simplify follow-up studies. , 2005, AJNR. American journal of neuroradiology.
[4] D. Lopes,et al. Evaluation of cerebral artery perforators and the pipeline embolization device using optical coherence tomography , 2011, Journal of NeuroInterventional Surgery.
[5] D. Kallmes,et al. Wall Apposition Is a Key Factor for Aneurysm Occlusion after Flow Diversion: A Histologic Evaluation in 41 Rabbits , 2016, American Journal of Neuroradiology.
[6] A. Wakhloo,et al. Quantitative analysis of high-resolution, contrast-enhanced, cone-beam CT for the detection of intracranial in-stent hyperplasia , 2014, Journal of NeuroInterventional Surgery.
[7] D. Lopes,et al. Analysis of neointima development in flow diverters using optical coherence tomography imaging , 2017, Journal of NeuroInterventional Surgery.
[8] H. Woo,et al. Long-Term Clinical and Angiographic Outcomes Following Pipeline Embolization Device Treatment of Complex Internal Carotid Artery Aneurysms: Five-Year Results of the Pipeline for Uncoilable or Failed Aneurysms Trial , 2017, Neurosurgery.
[9] Miguel Chagnon,et al. Flow diversion in the treatment of aneurysms: a randomized care trial and registry. , 2017, Journal of neurosurgery.
[10] K. van der Marel,et al. Grading of Regional Apposition after Flow-Diverter Treatment (GRAFT): a comparative evaluation of VasoCT and intravascular OCT , 2015, Journal of NeuroInterventional Surgery.
[11] D. Kallmes,et al. Safety and efficacy of the Pipeline embolization device for treatment of intracranial aneurysms: a pooled analysis of 3 large studies. , 2017, Journal of neurosurgery.
[12] Ryo Torii,et al. Incomplete Stent Apposition Causes High Shear Flow Disturbances and Delay in Neointimal Coverage as a Function of Strut to Wall Detachment Distance: Implications for the Management of Incomplete Stent Apposition , 2014, Circulation. Cardiovascular interventions.
[13] T A Altes,et al. 1999 ARRS Executive Council Award. Creation of saccular aneurysms in the rabbit: a model suitable for testing endovascular devices. American Roentgen Ray Society. , 2000, AJR. American journal of roentgenology.
[14] David F. Kallmes,et al. Creation of Saccular Aneurysms in the Rabbit , 2000 .
[15] N. Nakao,et al. Observation of Neointimal Coverage Around the Aneurysm Neck After Stent-Assisted Coil Embolization by Optical Frequency Domain Imaging: Technical Case Report. , 2017, Operative neurosurgery.
[16] T E Darsaut,et al. Flow Diverters Can Occlude Aneurysms and Preserve Arterial Branches: A New Experimental Model , 2012, American Journal of Neuroradiology.