Learning metal artifact reduction in cardiac CT images with moving pacemakers

Metal objects in the human heart such as implanted pacemakers frequently lead to heavy artifacts in reconstructed CT image volumes. Due to cardiac motion, common metal artifact reduction methods which assume a static object during CT acquisition are not applicable. We propose a fully automatic Dynamic Pacemaker Artifact Reduction (DyPAR+) pipeline which is built of three convolutional neural network (CNN) ensembles. In a first step, pacemaker metal shadows are segmented directly in the raw projection data by the SegmentationNets. Second, resulting metal shadow masks are passed to the InpaintingNets which replace metal-affected line integrals in the sinogram for subsequent reconstruction of a metal-free image volume. Third, the metal locations in a pre-selected motion state are predicted by the ReinsertionNets based on a stack of partial angle back-projections generated from the segmented metal shadow mask. We generate the data required for the supervised learning processes by introducing synthetic, moving pacemaker leads into 14 clinical cases without pacemakers. The SegmentationNets and the ReinsertionNets achieve average Dice coefficients of 94.16% ± 2.01% and 55.60% ± 4.79% during testing on clinical data with synthetic metal leads. With a mean absolute reconstruction error of 11.54 HU ± 2.49 HU in the image domain, the InpaintingNets outperform the hand-crafted approaches PatchMatch and inverse distance weighting. Application of the proposed DyPAR+ pipeline to nine clinical test cases with real pacemakers leads to significant reduction of metal artifacts and demonstrates the transferability to clinical practice. Especially the SegmentationNets and InpaintingNets generalize well to unseen acquisition modes and contrast protocols.

[1]  Thomas S. Huang,et al.  Free-Form Image Inpainting With Gated Convolution , 2018, 2019 IEEE/CVF International Conference on Computer Vision (ICCV).

[2]  Mehran Ebrahimi,et al.  EdgeConnect: Generative Image Inpainting with Adversarial Edge Learning , 2019, ArXiv.

[3]  Ge Wang,et al.  Metal Artifact Reduction in CT: Where Are We After Four Decades? , 2016, IEEE Access.

[4]  Johan Nuyts,et al.  Metal artifact reduction in computed tomography using local models in an image block-iterative scheme. , 2012, Medical physics.

[5]  L. Xing,et al.  Metal artifact reduction in x-ray computed tomography (CT) by constrained optimization. , 2011, Medical physics.

[6]  P. Suetens,et al.  Metal streak artifacts in X-ray computed tomography: a simulation study , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[7]  Marcus Brehm,et al.  Moving metal artifact reduction in cone-beam CT scans with implanted cylindrical gold markers. , 2014, Medical physics.

[8]  Olivier Ecabert,et al.  Automatic Model-Based Segmentation of the Heart in CT Images , 2008, IEEE Transactions on Medical Imaging.

[9]  C Haase,et al.  First pass cable artefact correction for cardiac C-arm CT imaging , 2014, Physics in medicine and biology.

[10]  Bruno De Man,et al.  Deep learning methods for CT image-domain metal artifact reduction , 2017, Optical Engineering + Applications.

[11]  Leon A. Gatys,et al.  Image Style Transfer Using Convolutional Neural Networks , 2016, 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR).

[12]  Jin Keun Seo,et al.  CT sinogram‐consistency learning for metal‐induced beam hardening correction , 2017, Medical physics.

[13]  Ting-Chun Wang,et al.  Partial Convolution based Padding , 2018, ArXiv.

[14]  Shiyu Xu,et al.  Deep residual learning enabled metal artifact reduction in CT , 2018, Medical Imaging.

[15]  Jimmy Ba,et al.  Adam: A Method for Stochastic Optimization , 2014, ICLR.

[16]  Thorsten M. Buzug,et al.  The λ-MLEM Algorithm: An Iterative Reconstruction Technique for Metal Artifact Reduction in CT Images , 2007 .

[17]  Rainer Raupach,et al.  Normalized metal artifact reduction (NMAR) in computed tomography. , 2010, Medical physics.

[18]  M Grass,et al.  Aperture weighted cardiac reconstruction for cone-beam CT , 2006, Physics in medicine and biology.

[19]  Thomas Brox,et al.  U-Net: Convolutional Networks for Biomedical Image Segmentation , 2015, MICCAI.

[20]  Yu Zhang,et al.  Metal artifact reduction on cervical CT images by deep residual learning , 2018, BioMedical Engineering OnLine.

[21]  Adam Finkelstein,et al.  PatchMatch: a randomized correspondence algorithm for structural image editing , 2009, SIGGRAPH 2009.

[22]  Ting-Chun Wang,et al.  Image Inpainting for Irregular Holes Using Partial Convolutions , 2018, ECCV.

[23]  W. Kalender,et al.  Reduction of CT artifacts caused by metallic implants. , 1987 .

[24]  Michael Grass,et al.  Dynamic Pacemaker Artifact Removal (DyPAR) from CT Data using CNNs , 2018, MIDL.

[25]  Marc Kachelrieß,et al.  Motion compensation in the region of the coronary arteries based on partial angle reconstructions from short‐scan CT data , 2017, Medical physics.

[26]  Ge Wang,et al.  Deep learning methods to guide CT image reconstruction and reduce metal artifacts , 2017, Medical Imaging.

[27]  Lin Yang,et al.  Combining Fully Convolutional and Recurrent Neural Networks for 3D Biomedical Image Segmentation , 2016, NIPS.

[28]  Joseph A. O'Sullivan,et al.  Iterative deblurring for CT metal artifact reduction , 1996, IEEE Trans. Medical Imaging.

[29]  Iasonas Kokkinos,et al.  DeepLab: Semantic Image Segmentation with Deep Convolutional Nets, Atrous Convolution, and Fully Connected CRFs , 2016, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[30]  Konstantin Nikolaou,et al.  Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation , 2011, European Radiology.

[31]  Rainer Raupach,et al.  Frequency split metal artifact reduction (FSMAR) in computed tomography. , 2012, Medical physics.

[32]  Jong Beom Ra,et al.  Cardiac motion correction based on partial angle reconstructed images in x-ray CT. , 2015, Medical physics.

[33]  Quynh A Truong,et al.  Cardiac CT: Imaging of and Through Cardiac Devices , 2012, Current Cardiovascular Imaging Reports.

[34]  D. Shepard A two-dimensional interpolation function for irregularly-spaced data , 1968, ACM National Conference.

[35]  Marcus Brehm,et al.  Two methods for reducing moving metal artifacts in cone‐beam CT , 2018, Medical physics.

[36]  Hengyong Yu,et al.  Convolutional Neural Network Based Metal Artifact Reduction in X-Ray Computed Tomography , 2017, IEEE Transactions on Medical Imaging.

[37]  Geoffrey E. Hinton,et al.  ImageNet classification with deep convolutional neural networks , 2012, Commun. ACM.

[38]  Ross B. Girshick,et al.  Focal Loss for Dense Object Detection , 2017, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[39]  Johan Nuyts,et al.  An experimental survey of metal artefact reduction in computed tomography. , 2013, Journal of X-ray science and technology.