Large-area solid state detector for radiology using amorphous selenium

A large area self-scanned solid-state detector is being developed for digital radiology. It consists of an x-ray sensitive flat-panel employing amorphous selenium ((alpha) )-Se) as the x- ray transducer and active matrix integrated circuit for readout. In principle such detectors could be used for all the currently applied radiological modalities -- radiography, photofluorography, and fluoroscopy. Layers of (alpha) )-Se up to 500 micrometers thick are readout with an array of thin film field effect transistors. The whole structure is integrated onto a glass plate. For all practical purposes the resolution of the system is dictated by the pixel size and readout could be in real-time (i.e., 30 frames/sec).

[1]  R A Gutcheck,et al.  Radiographic information theory and application to mammography. , 1982, Medical physics.

[2]  Ulrich Schiebel,et al.  A Selenium-Based Detector System For Digital Slot-Radiography , 1988, Medical Imaging.

[3]  A. W. Templeton,et al.  The cost of managing digital diagnostic images. , 1982, Radiology.

[4]  M. Giger,et al.  Computerized detection of pulmonary nodules in digital chest images: use of morphological filters in reducing false-positive detections. , 1990, Medical physics.

[5]  K Doi,et al.  Image feature analysis and computer-aided diagnosis in digital radiography. I. Automated detection of microcalcifications in mammography. , 1987, Medical physics.

[6]  G T Barnes,et al.  Radiographic mottle: a comprehensive theory. , 1982, Medical physics.

[7]  Ulrich Schiebel,et al.  Image Quality In Selenium-Based Digital Radiography , 1986, Other Conferences.

[8]  Larry E. Antonuk,et al.  Development of hydrogenated amorphous silicon sensors for high energy photon radiotherapy imaging , 1990 .

[9]  Larry E. Antonuk,et al.  Signal, noise, and readout considerations in the development of amorphous silicon photodiode arrays for radiotherapy and diagnostic x-ray imaging , 1991, Medical Imaging.

[10]  H Fujita,et al.  Basic imaging properties of a computed radiographic system with photostimulable phosphors. , 1989, Medical physics.

[11]  D M Hynes,et al.  System for digital acquisition of gastrointestinal images. , 1989, Medical physics.

[12]  John L. Donovan,et al.  Xeroradiographic Properties of Amorphous Selenium , 1970 .

[13]  R. F. Wagner,et al.  Absolute measures of physical image quality: measurement and application to radiographic magnification. , 1982, Medical physics.

[14]  J A Rowlands,et al.  X-ray imaging using amorphous selenium: a photoinduced discharge readout method for digital mammography. , 1991, Medical physics.

[15]  William D. Fender Quantification Of The Xeroradiographic Discharge Curve , 1976, Other Conferences.

[16]  Anthony R. Lubinsky,et al.  Storage Phosphor System For Computed Radiography: Destructive Scanning , 1986, Other Conferences.

[17]  Martin J. Yaffe,et al.  Characterization Of Mammographic Parenchymal Pattern By Fractal Dimension , 1989, Medical Imaging.

[18]  Philip Pettit,et al.  For a Comprehensive Theory , 1992 .