Infrared and near-infrared technology for the food industry and agricultural uses: on-line applications

Abstract Mid-infrared and near-infrared spectroscopy are well-known analytical tools for the food industry but they have different properties. On comparison, due to its lower absorption coefficients, near-infrared allows quantitative analysis, especially on solid samples, whereas, due to its high selectivity, mid-infrared is most suitable for qualitative analysis. The aim of this article is to present general guidelines for the choice of a technology according to the type of problem, of their use in two specific cases. The first example describes the most appropriate system for the quantification of individual sugars in a liquid mixture. Fourier transform/infrared spectroscopy is used to detect fructose and glucose in fermentation processes with standard errors of prediction respectively equal to 2.4 and 3.6 g/l. The second example describes a tool for solid product control at a high speed: near-infrared coupled with optical fibres is selected to detect sugar in fruit at a rate of three fruits per second.

[1]  D. Bertrand,et al.  Quantitative Determination of Sugar Cane Sucrose by Multidimensional Statistical Analysis of Their Mid-Infrared Attenuated Total Reflectance Spectra , 1991 .

[2]  C. Scotter Use of near infrared spectroscopy in the food industry with particular reference to its applications to on/in-line food processes , 1990 .

[3]  J. Hopkinson,et al.  Applications of attenuated total reflection in the infrared analysis of carbohydrates and biological whole cell samples in aqueous solution. , 1987, The Analyst.

[4]  I. C. Chang Development Of An Infrared Tunable Acousto-Optic Filter , 1978, Photonics West - Lasers and Applications in Science and Engineering.

[5]  P. C. Williams,et al.  Near-infrared reflectance analysis: food industry applications , 1990 .

[6]  F. R. Voort,et al.  Mid-Infrared Transmission Spectroscopy of Sugar Solutions: Instrumentation and Analysis , 1986 .

[7]  F. R. Voort,et al.  Proximate analysis of foods by mid-FTIR spectroscopy , 1991 .

[8]  Richard G. Leffler,et al.  Near Infrared Analysis of Soluble Solids in Intact Cantaloupe , 1989 .

[9]  R. G. Messerschmidt A New Internal Reflection Element Design for High Optical Throughput in FT-IR , 1986 .

[10]  J. Bertie,et al.  Infrared Intensities of Liquids I: Determination of Infrared Optical and Dielectric Constants by FT-IR Using the CIRCLE ATR Cell , 1985 .

[11]  John D. Feichtner,et al.  Microcomputer-Controlled Tunable Acousto-Optic Filter , 1980, Optics & Photonics.

[12]  P. Belton,et al.  Use of Fourier transform infrared spectroscopy for quantitative analysis: a comparative study of different detection methods. , 1987, The Analyst.

[13]  I. E. Rosenberg,et al.  On-line high-performance liquid chromatography/Fourier tranform infrared spectrometry with normal and reverse phases using an attenuated total reflectance flow cell , 1985 .