Monitoring of Cardiac Output Using a New Smartphone Application (Capstesia) vs. Vigileo FloTrac System
暂无分享,去创建一个
Fulvio Nisi | Chiara Melchiorri | Paola Di Grigoli | Enrico Giustiniano | Elisabetta Cerutti | Paolo Rispoli | Roberto Balagna | E. Cerutti | R. Balagna | E. Giustiniano | C. Melchiorri | F. Nisi | Paola di Grigoli | Paolo Rispoli
[1] J. Rinehart,et al. A Novel Mobile Phone Application for Pulse Pressure Variation Monitoring Based on Feature Extraction Technology: A Method Comparison Study in a Simulated Environment , 2016, Anesthesia and analgesia.
[2] S. Kopp,et al. Epidural pain relief versus systemic opioid-based pain relief for abdominal aortic surgery. , 2016, The Cochrane database of systematic reviews.
[3] J. Boldt,et al. Continuous arterial pressure waveform-based cardiac output using the FloTrac/Vigileo: a review and meta-analysis. , 2009, Journal of cardiothoracic and vascular anesthesia.
[4] L. Critchley,et al. A Meta-Analysis of Studies Using Bias and Precision Statistics to Compare Cardiac Output Measurement Techniques , 1999, Journal of Clinical Monitoring and Computing.
[6] U. Hariharan,et al. Cardiac output monitoring: A comparative prospective observational study of the conventional cardiac output monitor Vigileo™ and the new smartphone-based application Capstesia™ , 2018, Indian journal of anaesthesia.
[7] J. Vincent,et al. Ability of a New Smartphone Pulse Pressure Variation and Cardiac Output Application to Predict Fluid Responsiveness in Patients Undergoing Cardiac Surgery. , 2019, Anesthesia and analgesia.
[8] S. Chauhan,et al. Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output , 2012, Journal of Clinical Monitoring and Computing.
[9] J. Vincent,et al. Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients , 2010, Intensive Care Medicine.
[10] D. Altman,et al. STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.
[11] J. Headley. Arterial pressure-based technologies: a new trend in cardiac output monitoring. , 2006, Critical care nursing clinics of North America.
[12] G. Manecke. Edwards FloTrac™ sensor and Vigileo™ monitor: easy, accurate, reliable cardiac output assessment using the arterial pulse wave , 2005, Expert review of medical devices.
[13] R. Beale,et al. Pitfalls in haemodynamic monitoring based on the arterial pressure waveform , 2010, Critical care.
[14] Terry K Koo,et al. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. , 2016, Journal Chiropractic Medicine.
[15] J. Vincent,et al. Monitoring of pulse pressure variation using a new smartphone application (Capstesia) versus stroke volume variation using an uncalibrated pulse wave analysis monitor: a clinical decision making study during major abdominal surgery , 2019, Journal of Clinical Monitoring and Computing.