Development of a soft-inflatable exosuit for knee rehabilitation

This paper presents the design, development and preliminary evaluation of a soft-inflatable exosuit for knee rehabilitation. Soft-inflatable actuators made of heat-sealable thermoplastic polyurethane (TPU) materials are fabricated in two different beam-like structures (I and O cross-section actuators) and mechanically characterized for their torque performance in knee-extension assistance. The fabrication procedure of both types of actuators is presented as well as their integration into a lightweight, low-cost and body-conforming interface. To detect the activation duration of the device during the gait cycle, a soft-silicone insole with embedded force-sensitive resistors (FSRs) is used. In evaluation studies, the soft-inflatable exosuit device is tested for its ability to reduce muscle activity during the swing phase of the knee. Using sEMG (surface electromyography) sensors, the rectus femoris muscle group of a healthy individual is recorded while walking on a treadmill at a constant speed, with and without the soft device. Preliminary testing presents a promising 7% reduction in muscle activity and demonstrates the applicability of the soft-inflatable exosuit in knee rehabilitation scenarios.

[1]  Vernon Lin,et al.  Occupational Therapy Workforce in the United States: Forecasting Nationwide Shortages , 2015, PM & R : the journal of injury, function, and rehabilitation.

[2]  M. Polkey,et al.  Quadriceps muscle weakness following acute hemiplegic stroke , 2001, Clinical rehabilitation.

[3]  Siddharth Sanan,et al.  Pneumatic Torsional Actuators for Inflatable Robots , 2014 .

[4]  Daniel P. Ferris,et al.  A pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition , 2009, Journal of NeuroEngineering and Rehabilitation.

[5]  C. Walsh,et al.  Biomechanical and Physiological Evaluation of Multi-Joint Assistance With Soft Exosuits , 2017, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[6]  Robert J. Wood,et al.  A lightweight soft exosuit for gait assistance , 2013, 2013 IEEE International Conference on Robotics and Automation.

[7]  Homayoon Kazerooni,et al.  Lower Extremity Exoskeleton Reduces Back Forces in Lifting , 2009 .

[8]  Stephen A. Morin,et al.  Soft Robotics: Review of Fluid‐Driven Intrinsically Soft Devices; Manufacturing, Sensing, Control, and Applications in Human‐Robot Interaction   , 2017 .

[9]  R. Gregor,et al.  Knee joint torque during the swing phase of normal treadmill walking. , 1975, Journal of biomechanics.

[10]  Robert J. Wood,et al.  A soft wearable robotic device for active knee motions using flat pneumatic artificial muscles , 2014, 2014 IEEE International Conference on Robotics and Automation (ICRA).

[11]  Subashan Perera,et al.  Persisting Consequences of Stroke Measured by the Stroke Impact Scale , 2002, Stroke.

[12]  P. Sharma Mechanics of materials. , 2010, Technology and health care : official journal of the European Society for Engineering and Medicine.

[13]  S.K. Agrawal,et al.  Active Leg Exoskeleton (ALEX) for Gait Rehabilitation of Motor-Impaired Patients , 2007, 2007 IEEE 10th International Conference on Rehabilitation Robotics.

[14]  Nikolaos G. Tsagarakis,et al.  "Soft" Exoskeletons for Upper and Lower Body Rehabilitation - Design, Control and Testing , 2007, Int. J. Humanoid Robotics.

[15]  Christine Detrembleur,et al.  Effect of the rectus femoris motor branch block on post-stroke stiff-legged gait. , 2005, Acta neurologica Belgica.

[16]  Radhika Nagpal,et al.  Design and control of a bio-inspired soft wearable robotic device for ankle–foot rehabilitation , 2014, Bioinspiration & biomimetics.

[17]  H. van der Kooij,et al.  Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[18]  Conor J. Walsh,et al.  Assistance magnitude versus metabolic cost reductions for a tethered multiarticular soft exosuit , 2017, Science Robotics.

[19]  Emily Fox,et al.  Effects of Stroke Severity and Training Duration on Locomotor Recovery After Stroke: A Pilot Study , 2007, Neurorehabilitation and neural repair.

[20]  Bram Vanderborght,et al.  An exoskeleton for gait rehabilitation: Prototype design and control principle , 2008, 2008 IEEE International Conference on Robotics and Automation.

[21]  Robert A Siston,et al.  Gluteus maximus and soleus compensate for simulated quadriceps atrophy and activation failure during walking. , 2013, Journal of biomechanics.

[22]  Siddharth Sanan,et al.  Soft Inflatable Robots for Safe Physical Human Interaction , 2013 .

[23]  Hong Kai Yap,et al.  A soft exoskeleton for hand assistive and rehabilitation application using pneumatic actuators with variable stiffness , 2015, 2015 IEEE International Conference on Robotics and Automation (ICRA).

[24]  Juan Yi,et al.  Soft robotics for engineers , 2015 .

[25]  G. Whitesides,et al.  Pneumatic Networks for Soft Robotics that Actuate Rapidly , 2014 .