Quartz crystal microbalance setup for frequency and Q‐factor measurements in gaseous and liquid environments

An experimental setup has been constructed for simultaneous measurements of the frequency, the absolute Q factor, and the amplitude of oscillation of a quartz crystal microbalance (QCM). The technical solution allows operation in vacuum, air, or liquid. The crystal is driven at its resonant frequency by an oscillator that can be intermittently disconnected causing the crystal oscillation amplitude to decay exponentially. From the recorded decay curve the absolute Q factor (calculated from the decay time constant), the frequency of the freely oscillating crystal, and the amplitude of oscillation are obtained. All measurements are fully automated. One electrode of the QCM in our setup was connected to true ground which makes possible simultaneous electrochemistry. The performance is illustrated by experiments in fluids of varying viscosity (gas and liquid) and by proteinadsorptionin situ. We found, in addition to the above results, that the amplitude of oscillation is not always directly proportional to the Q factor, as the commonly used theory states. This puts limitations on the customary use of the amplitude of oscillation as a measure of the Q factor.

[1]  D. M. Soares,et al.  The electrochemical quartz‐microbalance in media of changing viscoelastic properties, and the design and characterization of a suitable driver electronics , 1994 .

[2]  V. M. Mecea,et al.  Loaded vibrating quartz sensors , 1994 .

[3]  Stephen J. Martin,et al.  Effect of surface roughness on the response of thickness-shear mode resonators in liquids , 1993 .

[4]  W. Pietro,et al.  A high‐stability quartz crystal microbalance electrode for simultaneous solution‐phase electrochemistry/microgravitometry , 1993 .

[5]  C. Barnes Some new concepts on factors influencing the operational frequency of liquid-immersed quartz microbalances , 1992 .

[6]  C. Barnes,et al.  Development of quartz crystal oscillators for under-liquid sensing , 1991 .

[7]  C. Barnes,et al.  A concanavalin A-coated piezoelectric crystal biosensor , 1991 .

[8]  J. Krim,et al.  Sliding friction measurements of physisorbed monolayers: A comparison of solid and liquid films , 1991 .

[9]  Y. Okahata,et al.  ABSORPTION BEHAVIORS OF SURFACTANT MOLECULES ON A LIPID-COATED QUARTZ-CRYSTAL MICROBALANCE. AN ALTERNATIVE TO EYE-IRRITANT TESTS , 1991 .

[10]  W. M. Haynes CRC Handbook of Chemistry and Physics , 1990 .

[11]  William H. Press,et al.  Numerical Recipes: FORTRAN , 1988 .

[12]  Michael D. Ward,et al.  Amplified mass immunosorbent assay with a quartz crystal microbalance , 1988 .

[13]  Alan Townshend,et al.  Applications of piezoelectric quartz crystal microbalances , 1987 .

[14]  J. Gordon,et al.  Direct determination of the mass of an underpotentially deposited monolayer of lead on gold , 1986 .

[15]  Krim,et al.  Q-factors of quartz oscillator modes as a probe of submonolayer-film dynamics. , 1986, Physical review. B, Condensed matter.

[16]  David J. Bishop,et al.  Single‐crystal silicon high‐Q torsional oscillators , 1985 .

[17]  J. Gordon,et al.  Frequency of a quartz microbalance in contact with liquid , 1985 .

[18]  Toshiaki Nomura,et al.  Frequency shifts of piezoelectric quartz crystals immersed in organic liquids , 1982 .

[19]  B. Kasemo,et al.  Weighing Fractions of Monolayers: Application to the Adsorption and Catalytic Reactions of H 2 , CO, and O 2 on Pt , 1980 .

[20]  D. Bishop,et al.  Study of the Superfluid Transition in Two-Dimensional He-4 Films , 1978 .

[21]  Arthur Ballato,et al.  Electronic Activity Dip Measurement , 1978, IEEE Transactions on Instrumentation and Measurement.

[22]  A. Czanderna,et al.  Vacuum Microbalance Techniques , 1967 .

[23]  W. J. Spencer,et al.  Defects in Natural Quartz , 1966 .