A comprehensive quality assurance program for personnel and procedures in radiation oncology: value of voluntary error reporting and checklists.

PURPOSE This report describes the value of a voluntary error reporting system and the impact of a series of quality assurance (QA) measures including checklists and timeouts on reported error rates in patients receiving radiation therapy. METHODS AND MATERIALS A voluntary error reporting system was instituted with the goal of recording errors, analyzing their clinical impact, and guiding the implementation of targeted QA measures. In response to errors committed in relation to treatment of the wrong patient, wrong treatment site, and wrong dose, a novel initiative involving the use of checklists and timeouts for all staff was implemented. The impact of these and other QA initiatives was analyzed. RESULTS From 2001 to 2011, a total of 256 errors in 139 patients after 284,810 external radiation treatments (0.09% per treatment) were recorded in our voluntary error database. The incidence of errors related to patient/tumor site, treatment planning/data transfer, and patient setup/treatment delivery was 9%, 40.2%, and 50.8%, respectively. The compliance rate for the checklists and timeouts initiative was 97% (P<.001). These and other QA measures resulted in a significant reduction in many categories of errors. The introduction of checklists and timeouts has been successful in eliminating errors related to wrong patient, wrong site, and wrong dose. CONCLUSIONS A comprehensive QA program that regularly monitors staff compliance together with a robust voluntary error reporting system can reduce or eliminate errors that could result in serious patient injury. We recommend the adoption of these relatively simple QA initiatives including the use of checklists and timeouts for all staff to improve the safety of patients undergoing radiation therapy in the modern era.

[1]  W. Berry,et al.  Changes in safety attitude and relationship to decreased postoperative morbidity and mortality following implementation of a checklist-based surgical safety intervention , 2011, Quality and Safety in Health Care.

[2]  Todd Pawlicki,et al.  Quality and Safety in Radiotherapy , 2010 .

[3]  Jean-Pierre Bissonnette,et al.  Error in the delivery of radiation therapy: results of a quality assurance review. , 2005, International journal of radiation oncology, biology, physics.

[4]  J. Moran,et al.  Quality, technology and outcomes: evolution and evaluation of new treatments and/or new technology. , 2012, Seminars in radiation oncology.

[5]  T. Brennan,et al.  INCIDENCE OF ADVERSE EVENTS AND NEGLIGENCE IN HOSPITALIZED PATIENTS , 2008 .

[6]  Margie A Hunt,et al.  The impact of new technologies on radiation oncology events and trends in the past decade: an institutional experience. , 2012, International journal of radiation oncology, biology, physics.

[7]  J. Galvin,et al.  Safety considerations for IMRT: Executive summary , 2011, Practical radiation oncology.

[8]  W. Berry,et al.  A Surgical Safety Checklist to Reduce Morbidity and Mortality in a Global Population , 2009, The New England journal of medicine.

[9]  M. Brundage,et al.  A real-time audit of radiation therapy in a regional cancer center. , 1999, International journal of radiation oncology, biology, physics.

[10]  L. Kohn,et al.  To Err Is Human : Building a Safer Health System , 2007 .

[11]  J. Williamson,et al.  Quality assurance needs for modern image-based radiotherapy: recommendations from 2007 interorganizational symposium on "quality assurance of radiation therapy: challenges of advanced technology". , 2008, International journal of radiation oncology, biology, physics.

[12]  Laval Grimard,et al.  The management of radiation treatment error through incident learning. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[13]  G. Starkschall,et al.  American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: quality assurance for clinical radiotherapy treatment planning. , 1998, Medical physics.

[14]  P J Biggs,et al.  AAPM code of practice for radiotherapy accelerators: report of AAPM Radiation Therapy Task Group No. 45. , 1994, Medical physics.

[15]  Joanne Cunningham Radiation oncology safety information system (ROSIS) : a reporting and learning system for radiation oncology , 2011 .

[16]  Ravinder Nath,et al.  AAPM Code of Practice for Radiotherapy Accelerators , 2000 .

[17]  T. K. Yeung,et al.  Quality assurance in radiotherapy: evaluation of errors and incidents recorded over a 10 year period. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[18]  R. Macklis,et al.  Error rates in clinical radiotherapy. , 1998, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[19]  A. Wall,et al.  Book ReviewTo Err is Human: building a safer health system Kohn L T Corrigan J M Donaldson M S Washington DC USA: Institute of Medicine/National Academy Press ISBN 0 309 06837 1 $34.95 , 2000 .

[20]  D L McShan,et al.  The impact of treatment complexity and computer-control delivery technology on treatment delivery errors. , 1998, International journal of radiation oncology, biology, physics.