Quantitative Study on MFL Signal of Pipeline Composite Defect Based on Improved Magnetic Charge Model

Pipeline magnetic flux leakage (MFL) internal detection technology is the most widely used and effective method in the field of long-distance oil and gas pipeline online detection. With the improvement of data quantization precision, the influence of stress on MFL signal has been paid more and more attention. In this paper, the relationship between stress and saturation magnetization is introduced based on J-A theory. The analytical model of MFL detection signal for pipeline composite defects is established. The MFL signal characteristics of composite defects are quantitatively calculated. The effect of stress on MFL signal is studied. The theoretical analysis is verified by experimental data and excavation results. The researches show that the saturation magnetization of ferromagnets decreases exponentially with the increase of stress in strong magnetic field. The MFL signal of composite defect is weaker than that of volumetric defects of the same dimension. The axial amplitude and radial peak-to-peak value of MFL signal decrease with the increase of stress around the defect. The axial amplitude and radial peak-to-peak value of MFL signal increase non-linearly with the increase of width and depth of defects. When using MFL signal to judge the defect depth, it is necessary to make clear whether there is stress concentration phenomenon around the defect because the stress will lead to underestimation of the defect depth.

[1]  Bin Liu,et al.  Research on internal detection technology for axial crack of long-distance oil and gas pipeline based on micromagnetic method , 2020, Structural Health Monitoring.

[3]  Bin Liu,et al.  Research on Features of Pipeline Crack Signal Based on Weak Magnetic Method , 2020, Sensors.

[4]  Zheng Xiaojing,et al.  Magnetic charge model for 3D MMM signals , 2016 .

[5]  Mehrdad Kashefi,et al.  Effect of sample initial magnetic field on the metal magnetic memory NDT result , 2018, Journal of Magnetism and Magnetic Materials.

[6]  Zhenmao Chen,et al.  The magneto-elastoplastic coupling effect on the magnetic flux leakage signal , 2020 .

[7]  Vladimir Bratov,et al.  Comparison of dislocation density based approaches for prediction of defect structure evolution in aluminium and copper processed by ECAP , 2015 .

[8]  Yan Shi,et al.  Theory and Application of Magnetic Flux Leakage Pipeline Detection , 2015, Sensors.

[9]  Yue-Sheng Wang,et al.  Influence of inhomogeneous stress on biaxial 3D magnetic flux leakage signals , 2020 .

[10]  Kazumasa Nishio,et al.  The influence of modeled B–H curve on the density of the magnetic leakage flux due to a flaw using yoke-magnetization , 2004 .

[11]  Y. F. Cheng,et al.  An experimental investigation of corrosion of X100 pipeline steel under uniaxial elastic stress in a near-neutral pH solution , 2012 .

[12]  Ziguang Chen,et al.  A peridynamic mechano-chemical damage model for stress-assisted corrosion , 2019, Electrochimica Acta.

[13]  Bin Wu,et al.  Stress-Dependent Magnetic Flux Leakage: Finite Element Modelling Simulations Versus Experiments , 2019, Journal of Nondestructive Evaluation.

[14]  G Katragadda A comparative study of 3D and axisymmetric magnetizer assemblies used in magnetic flux leakage inspection of pipelines , 1996 .

[15]  Pengpeng Shi,et al.  Overview of Researches on the Nondestructive Testing Method of Metal Magnetic Memory: Status and Challenges , 2020 .

[16]  Young Eui Kwon,et al.  Review of magnetostrictive patch transducers and applications in ultrasonic nondestructive testing of waveguides. , 2015, Ultrasonics.

[17]  Z. D. Wang,et al.  A review of three magnetic NDT technologies , 2012 .

[18]  Yuesheng Wang,et al.  Application of Metal Magnetic Memory Testing Technology to the Detection of Stress Corrosion Defect , 2020, Applied Sciences.