The Effect of Support Conditions on the Fire Resistance of a Reinforced Concrete Beam

This report examines the behaviour of reinforced concrete beams with rectangular crosssection exposed to fire from the bottom and the sides. The study was performed with 2D finite element analysis using SAFIR. The effect of various support conditions was studied during the exposure to a four-hour ISO-fire for single-span beams with pinned and rotationally restrained supports, allowing for varying levels of horizontal restraint in both cases. The results showed that the provision of horizontal restraint was beneficial to the fire resistance of the beams in both cases. The provision of rotational restraint greatly improved the behaviour of the beams compared to the pinned supported case. The effect of continuity was investigated with beams spanning over two and three bays subjected to a four-hour ISO-fire. Within this analysis the effect of different lengths of the top reinforcing bars at the supports was investigated. Compared to the single span beam, the continuous beams resisted the fire exposure for a longer period of time. The different lengths of the reinforcing bars did not greatly increase the fire resistance of the beams. The influence of the full process of fire development was analysed with one, two and three-bay beams without horizontal restraint. These beams were exposed to the ISO-fire for 30, 60 and 90 minutes followed by a decay phase. The analysed beams showed good behaviour. Failure only occurred when the decay phase started close to the failure time reached during the full ISO-fire.

[1]  Bruce R. Ellingwood,et al.  Effects of Fire on Reinforced Concrete Members , 1980 .

[2]  Ian Burgess,et al.  Non-linear modelling of three full scale structural fire tests , 2000 .

[3]  Ian Burgess,et al.  A generalised steel/reinforced concrete beam-column element model for fire conditions , 2003 .

[4]  Colin Bailey,et al.  The behaviour of full-scale steel-framed buildings subjected to compartment fires , 1999 .

[5]  Gabriel A. Khoury,et al.  Transient thermal strain of concrete: literature review, conditions within specimen and behaviour of individual constituents , 1985 .

[6]  S Selvaggio,et al.  Effect of Restraint on Fire Resistance of Prestressed Concrete , 1963 .

[7]  Asif Usmani,et al.  Bending and membrane action in concrete slabs , 2004 .

[8]  Andrew H. Buchanan,et al.  Structural Design for Fire Safety , 2001 .

[9]  Z. Bažant,et al.  Concrete at High Temperatures: Material Properties and Mathematical Models , 1996 .

[10]  Andrew H. Buchanan,et al.  Restraint of fire‐exposed concrete floor systems , 2004 .

[11]  B Ellingwood,et al.  FLEXURAL AND SHEAR BEHAVIOR OF REINFORCED CONCRETE BEAMS DURING FIRE TESTS , 1988 .

[12]  B. R. Kirby,et al.  High temperature properties of hot-rolled, structural steels for use in fire engineering design studies , 1988 .

[13]  Frederic Gens,et al.  Dynamic Analysis Used to Cope with Partial and Temporary Failures , 2004 .

[14]  Asif Usmani,et al.  Composite beams in large buildings under fire -- numerical modelling and structural behaviour , 2000 .

[15]  H. L. Malhotra Design of fire-resisting structures , 1982 .

[16]  Susan Lamont The Behaviour of Multi-storey Composite Steel Framed Structures in Response to Compartment Fires , 2005 .

[17]  Kristian Dahl Hertz,et al.  Limits of spalling of fire-exposed concrete , 2003 .

[18]  Goran Turk,et al.  Non-linear fire resistance analysis of reinforced concrete frames , 2001 .

[19]  Yngve Anderberg,et al.  FIRE RESISTANCE OF CONCRETE STRUCTURES , 1982 .

[20]  Gabriel A. Khoury,et al.  Strain of concrete during first heating to 600°C under load , 1985 .

[21]  G. Charles Clifton,et al.  MODELLING OF THE CARDINGTON LBTF STEEL FRAME BUILDING FIRE TESTS , 2004 .

[22]  Jean-Marc Franssen,et al.  Design And Tests Of Prestressed Concrete Beams , 1997 .

[23]  Ulrich Schneider,et al.  Concrete at High Temperatures -- A General Review* , 1988 .

[24]  Jean-Marc Franssen,et al.  Numerical modelling of two-way reinforced concrete slabs in fire , 2004 .

[25]  Zhaohui Huang,et al.  Non-linear structural modelling of a fire test subject to high restraint , 2001 .