State of the art in trueness and interlaboratory harmonization for 10 analytes in general clinical chemistry.

CONTEXT Harmonization and standardization of results among different clinical laboratories is necessary for clinical practice guidelines to be established. OBJECTIVE To evaluate the state of the art in measuring 10 routine chemistry analytes. DESIGN A specimen prepared as off-the-clot pooled sera and 4 conventionally prepared specimens were sent to participants in the College of American Pathologists Chemistry Survey. Analyte concentrations were assigned by reference measurement procedures. PARTICIPANTS Approximately 6000 clinical laboratories. RESULTS For glucose, iron, potassium, and uric acid, more than 87.5% of peer groups meet the desirable bias goals based on biologic variability criteria. The remaining 6 analytes had less than 52% of peer groups that met the desirable bias criteria. CONCLUSIONS Routine measurement procedures for some analytes had acceptable traceability to reference systems. Conventionally prepared proficiency testing specimens were not adequately commutable with a fresh frozen specimen to be used to evaluate trueness of methods compared with a reference measurement procedure.

[1]  L. Siekmann,et al.  Measurement of urea in human serum by isotope dilution mass spectrometry: a reference procedure. , 1999, Clinical chemistry.

[2]  C Franzini,et al.  Analytical quality specifications for reference methods and operating specifications for networks of reference laboratories. discussion paper from the members of the external quality assessment (EQA) Working Group B1) on target values in EQAS. , 1995, European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies.

[3]  J. Praestgaard,et al.  The accuracy of laboratory measurements in clinical chemistry: a study of 11 routine chemistry analytes in the College of American Pathologists Chemistry Survey with fresh frozen serum, definitive methods, and reference methods. , 1998, Archives of pathology & laboratory medicine.

[4]  H. Reinauer,et al.  Candidate reference methods for determining target values for cholesterol, creatinine, uric acid, and glucose in external quality assessment and internal accuracy control. I. Method setup. , 1993, Clinical chemistry.

[5]  C Ricós,et al.  Current databases on biological variation: pros, cons and progress. , 1999, Scandinavian journal of clinical and laboratory investigation.

[6]  Cas Weykamp,et al.  Selection, preparation, and characterization of commutable frozen human serum pools as potential secondary reference materials for lipid and apolipoprotein measurements: study within the framework of the Dutch project "Calibration 2000". , 2002, Clinical chemistry.

[7]  W Greg Miller,et al.  Why commutability matters. , 2006, Clinical chemistry.

[8]  Cas Weykamp,et al.  IFCC reference system for measurement of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study. , 2004, Clinical chemistry.

[9]  Callum G. Fraser,et al.  Biological Variation: From Principles to Practice , 2001 .

[10]  H. Reinauer,et al.  Candidate reference methods for determining target values for cholesterol, creatinine, uric acid, and glucose in external quality assessment and internal accuracy control. II. Method transfer. , 1993, Clinical chemistry.

[11]  C. H. Fiske,et al.  THE COLORIMETRIC DETERMINATION OF PHOSPHORUS , 1925 .

[12]  L. Kaplan,et al.  Clinical Chemistry: Theory, Analysis, and Correlation , 1984 .

[13]  R. Miller,et al.  Revisions of the 1963 semidine HC1 standard method for inorganic phosphorus. , 1983, Clinical chemistry.

[14]  C. Burtis,et al.  A coupled-enzyme equilibrium method for measuring urea in serum: optimization and evaluation of the AACC study group on urea candidate reference method. , 1980, Clinical chemistry.

[15]  C G Fraser,et al.  Introduction: strategies to set global quality specifications in laboratory medicine. , 1999, Scandinavian journal of clinical and laboratory investigation.

[16]  A. Killeen,et al.  Creatinine measurement: state of the art in accuracy and interlaboratory harmonization. , 2005, Archives of pathology & laboratory medicine.

[17]  W. Miller,et al.  College of American Pathologists Conference XXIII on matrix effects and accuracy assessment in clinical chemistry: introduction. , 1993, Archives of pathology & laboratory medicine.

[18]  D. Bayse,et al.  A candidate reference method for uric acid in serum. I. Optimization and evaluation. , 1982, Clinical chemistry.

[19]  R. Mccomb,et al.  Candidate reference method for determination of total bilirubin in serum: development and validation. , 1985, Clinical chemistry.

[20]  L. Siekmann Determination of Uric Acid in Human Serum by Isotope Dilution-Mass Spectrometry. Definitive Methods in Clinical Chemistry, III , 1985, Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie.

[21]  Carmen Ricós,et al.  Characterization and classification of external Quality Assessment Schemes (EQA) according to objectives such as evaluation of method and participant bias and standard deviation , 1996 .

[22]  W Greg Miller,et al.  Specimen materials, target values and commutability for external quality assessment (proficiency testing) schemes. , 2003, Clinica chimica acta; international journal of clinical chemistry.