Clinical Performance of a New Medullary Humeral Nail: Antegrade Versus Retrograde Insertion

Objective A new intramedullary nail system for humeral shaft fractures is evaluated to determine whether retrograde nailing is as reliable as antegrade nailing. Study Design Prospective multicenter nonrandomized clinical study. Patients Eighty-four patients with acute humeral shaft fractures were nailed with the new unreamed humeral nail (UHN) system. Fifty-seven nails were introduced retrogradely, and twenty-seven antegradely. Bone healing and functional outcome were the follow-up parameters. Results The ratio of perioperative complications was equivalent for both groups, but one shaft fracture and three fractures or fissures at the entry point occurred in the group with retrograde nail insertion. Five fractures, all with retrograde nail insertion, needed secondary surgery to achieve bony healing. There was no difference in functional outcome after healing in either group. Conclusion Retrograde nailing of humeral shaft fractures is technically more demanding than antegrade nailing. Fractures or fissures at the insertion point must be avoided by adequate preparation of the entry hole and careful nail insertion. Bone healing problems seem more surgeon-related than approach-related. As in every other procedure, an optimal fracture configuration and high fracture stability must be achieved.

[1]  W. Ruf,et al.  [Interlocking nailing of the humerus]. , 1993, Der Unfallchirurg.

[2]  B.Sc. F.R.C.S. Joseph Schatzker M.D.,et al.  The Rationale of Operative Fracture Care , 1987, Springer Berlin Heidelberg.

[3]  T. Wisniewski,et al.  Gunshot fractures of the humeral shaft treated with external fixation. , 1996, Journal of orthopaedic trauma.

[4]  T. Wallny,et al.  Functional treatment of humeral shaft fractures: indications and results. , 1997, Journal of orthopaedic trauma.

[5]  C. Court-Brown,et al.  Locked nailing of humeral shaft fractures. Experience in Edinburgh over a two-year period. , 1992, The Journal of bone and joint surgery. British volume.

[6]  E. Chao,et al.  Biomechanical Comparison of Antegrade and Retrograde Nailing of Humeral Shaft Fracture , 1998, Clinical orthopaedics and related research.

[7]  J Schatzker,et al.  A study of implant failure in the Wagner resurfacing arthroplasty. , 1985, The Journal of bone and joint surgery. American volume.

[8]  L. Schweiberer,et al.  [The treatment of humeral shaft fractures. Results of a prospective AO multicenter study]. , 1991, Der Unfallchirurg.

[9]  R. V. Vander Griend,et al.  Open reduction and internal fixation of humeral shaft fractures. Results using AO plating techniques. , 1986, The Journal of bone and joint surgery. American volume.

[10]  I. Mackay Closed Rush pinning of fractures of the humeral shaft. , 1984, Injury.

[11]  M. Bell,et al.  The results of plating humeral shaft fractures in patients with multiple injuries. The Sunnybrook experience. , 1985, The Journal of bone and joint surgery. British volume.

[12]  H Seidel,et al.  Humeral locking nail: a preliminary report. , 1989, Orthopedics.

[13]  Serge Nazarian,et al.  Classification AO des fractures , 1987 .

[14]  K. Saunders,et al.  Hackethal stacked nailing of humeral shaft fractures. Experience with 30 patients. , 1983, Clinical orthopaedics and related research.

[15]  R. Brumback,et al.  Intramedullary stabilization of humeral shaft fractures in patients with multiple trauma. , 1986, The Journal of bone and joint surgery. American volume.

[16]  P. Rommens,et al.  The unreamed humeral nail--a biological osteosynthesis of the upper arm. , 1997, Acta chirurgica Belgica.

[17]  H. Kim,et al.  Intramedullary entrapment of the radial nerve associated with humeral shaft fracture. , 1997, Journal of orthopaedic trauma.

[18]  P. Broos,et al.  [Retrograde interlocking nailing of fracture of the humeral shaft. A clinical study]. , 1995, Der Unfallchirurg.

[19]  J. Rush Closed nailing of the humerus--from down under. , 1987, The Australian and New Zealand journal of surgery.

[20]  R. Blasier,et al.  Management of humeral nonunion after the failure of locking intramedullary nails. , 1996, Journal of orthopaedic trauma.

[21]  P. Regazzoni,et al.  Surgical treatment of humeral shaft fractures--the Basel experience. , 1993, The Journal of trauma.

[22]  T. Miclau,et al.  Segmental avascularity of the humeral diaphysis after reamed intramedullary nailing. , 1997, Journal of orthopaedic trauma.

[23]  R. Hoffmann,et al.  Nonunion of the humerus following intramedullary nailing treated by Ilizarov hybrid fixation. , 1998, Journal of orthopaedic trauma.

[24]  R. J. Foster,et al.  Internal fixation of fractures and non-unions of the humeral shaft. Indications and results in a multi-center study. , 1985, The Journal of bone and joint surgery. American volume.

[25]  P. Rommens,et al.  Retrograde nailing of humeral shaft fractures with the UHN. An international multicenter survey , 1998, Der Unfallchirurg.

[26]  O. Trentz,et al.  [Intramedullary nailing of the humerus shaft fracture]. , 1994, Der Unfallchirurg.

[27]  P. Rommens,et al.  Retrograde Nailing of Fresh and Pathologic Humeral Shaft Fractures With a New Unreamed Humeral Nail (UHN) , 1998 .

[28]  J. Derweduwen A new intramedullary compression device for fractures and pseudarthroses of the long bones. A preliminary report. , 1979, Acta orthopaedica Belgica.

[29]  G. Varley The Seidel locking humeral nail: the Nottingham experience. , 1995, Injury.

[30]  P. Broos,et al.  Retrograde locked nailing of humeral shaft fractures. A review of 39 patients. , 1995, The Journal of bone and joint surgery. British volume.

[31]  P. Broos,et al.  [Indications, dangers and results of surgical treatment of humeral shaft fractures]. , 1989, Der Unfallchirurg.

[32]  J. Chapman,et al.  Closed retrograde Hackethal nail stabilization of humeral shaft fractures. , 1992, Journal of orthopaedic trauma.

[33]  S. Krikler The rationale of operative fracture care, 2nd ed. , 1997 .

[34]  K. Hamoud,et al.  External fixation for severe open fractures of the humerus caused by missiles. , 1997, Journal of orthopaedic trauma.

[35]  P. Rommens,et al.  Retrograde nailing of humeral shaft fractures. , 1998, Clinical orthopaedics and related research.

[36]  R. F. Hall,et al.  Ender nailing of acute fractures of the humerus. A study of closed fixation by intramedullary nails without reaming. , 1987, The Journal of bone and joint surgery. American volume.

[37]  J. O. Ikpeme Intramedullary interlocking nailing for humeral fractures: experiences with the Russell-Taylor humeral nail. , 1994, Injury.

[38]  A. M. Ingman,et al.  Locked intramedullary nailing of humeral shaft fractures. Implant design, surgical technique, and clinical results. , 1994, The Journal of bone and joint surgery. British volume.

[39]  J. Lin,et al.  Treatment of humeral shaft fractures with humeral locked nail and comparison with plate fixation. , 1998, The Journal of trauma.

[40]  L. Schweiberer Retrograde Nagelung von Humerusschaftfrakturen mit dem UHN Eine internationale multizentrische Studie , 1998 .

[41]  R. D'ambrosia,et al.  Seidel intramedullary nailing of humeral diaphyseal fractures: a preliminary report. , 1991, Orthopedics.

[42]  R. D'ambrosia,et al.  Plate fixation of the humeral shaft for acute fractures, with and without radial nerve injuries. , 1992, Journal of orthopaedic trauma.