The use of phase sequence image sets to reconstruct the total volume occupied by a mobile lung tumor.

The use of phase sequence image (PSI) sets to reveal the total volume occupied by a mobile target is presented. Isocontrast composite clinical target volumes (CCTVs) may be constructed from PSI sets in order to reveal the total volume occupied by a mobile target during the course of its travel. The ability of the CCTV technique to properly account for target motion is demonstrated by comparison to contours of the true total volume occupied (TVO) for a number of experimental phantom geometries. Finally, using real patient data, the clinical utility of the CCTV technique to properly account for internal tumor motion while minimizing the volume of healthy lung tissue irradiated is assessed by comparison to the standard approach of applying safety margins. Results of the phantom study reveal that CCTV cross sections constructed at the 20% isocontrast level yield good agreement with the total cross sections (TXO) of mobile targets. These CCTVs conform well to the TVOs of the moving targets examined whereby the addition of small uniform margins ensures complete circumscription of the TVO with the inclusion of minimal amounts of surrounding external volumes. The CCTV technique is seen to be clearly superior to the common practice of the addition of safety margins to individual CTV contours in order to account for internal target motion. Margins required with the CCTV technique are eight to ten times smaller than those required with individual CTVs.

[1]  G. Sibley Radiotherapy for patients with medically inoperable stage I nonsmall cell lung carcinoma , 1998, Cancer.

[2]  B. Murray,et al.  Setup reproducibility in radiation therapy for lung cancer: a comparison between T-bar and expanded foam immobilization devices. , 1999, International journal of radiation oncology, biology, physics.

[3]  J. Ciezki,et al.  Fluoroscopic study of tumor motion due to breathing: facilitating precise radiation therapy for lung cancer patients. , 2001, Medical physics.

[4]  H. Mostafavi,et al.  Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center. , 2000, Medical physics.

[5]  W. Stanford,et al.  Analysis of movement of intrathoracic neoplasms using ultrafast computerized tomography. , 1990, International journal of radiation oncology, biology, physics.

[6]  Isabelle M Gagné,et al.  The impact of tumor motion upon CT image integrity and target delineation. , 2004, Medical physics.

[7]  Icru Prescribing, recording, and reporting photon beam therapy , 1993 .

[8]  S Senan,et al.  Multiple "slow" CT scans for incorporating lung tumor mobility in radiotherapy planning. , 2001, International journal of radiation oncology, biology, physics.

[9]  J C Rosenwald,et al.  Conformal radiotherapy (CRT) planning for lung cancer: analysis of intrathoracic organ motion during extreme phases of breathing. , 2001, International journal of radiation oncology, biology, physics.

[10]  T. Bortfeld,et al.  Introduction: intrafractional organ motion and its management , 2004 .

[11]  R. Mohan,et al.  Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker. , 2003, Medical physics.

[12]  B. Murray,et al.  Held-breath self-gating technique for radiotherapy of non-small-cell lung cancer: a feasibility study. , 2001, International journal of radiation oncology, biology, physics.

[13]  H. Shirato,et al.  Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. , 2000, International journal of radiation oncology, biology, physics.

[14]  Koichi Yamazaki,et al.  Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[15]  Gikas S. Mageras,et al.  Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system , 2001, Journal of applied clinical medical physics.

[16]  G J Kutcher,et al.  Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation. , 1999, International journal of radiation oncology, biology, physics.

[17]  R K Ten Haken,et al.  The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy. , 2001, International journal of radiation oncology, biology, physics.

[18]  Steve B. Jiang,et al.  Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation. , 2002, Physics in medicine and biology.

[19]  J. Bradley,et al.  Acute and late toxicity results of RTOG 9311: a dose escalation study using 3D conformal radiation therapy in patients with inoperable non-small cell lung cancer , 2003 .

[20]  M. V. van Herk,et al.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[21]  Michael B Sharpe,et al.  Initial clinical experience with moderate deep-inspiration breath hold using an active breathing control device in the treatment of patients with left-sided breast cancer using external beam radiation therapy. , 2003, International journal of radiation oncology, biology, physics.

[22]  H. Kubo,et al.  Respiration gated radiotherapy treatment: a technical study. , 1996, Physics in medicine and biology.

[23]  R. Mohan,et al.  Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. , 2003, Physics in medicine and biology.

[24]  R. Mohan,et al.  Motion adaptive x-ray therapy: a feasibility study , 2001, Physics in medicine and biology.

[25]  Curtis B Caldwell,et al.  Can PET provide the 3D extent of tumor motion for individualized internal target volumes? A phantom study of the limitations of CT and the promise of PET. , 2003, International journal of radiation oncology, biology, physics.

[26]  P. Keall 4-dimensional computed tomography imaging and treatment planning. , 2004, Seminars in radiation oncology.

[27]  E. Larsen,et al.  A method for incorporating organ motion due to breathing into 3D dose calculations. , 1999, Medical physics.

[28]  Martin J Murphy,et al.  Issues in respiratory motion compensation during external-beam radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[29]  T. Landberg,et al.  What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer? , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[30]  Tinsu Pan,et al.  4D computed tomography for treatment planning , 2003 .

[31]  Michael B Sharpe,et al.  Significant reductions in heart and lung doses using deep inspiration breath hold with active breathing control and intensity-modulated radiation therapy for patients treated with locoregional breast irradiation. , 2003, International journal of radiation oncology, biology, physics.

[32]  C. Ling,et al.  Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer. , 2000, International journal of radiation oncology, biology, physics.

[33]  H Shirato,et al.  Detection of lung tumor movement in real-time tumor-tracking radiotherapy. , 2001, International journal of radiation oncology, biology, physics.

[34]  Hiroshi Onishi,et al.  A new irradiation system for lung cancer combining linear accelerator, computed tomography, patient self-breath-holding, and patient-directed beam-control without respiratory monitoring devices. , 2003, International journal of radiation oncology, biology, physics.

[35]  C C Ling,et al.  The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer. , 2000, International journal of radiation oncology, biology, physics.

[36]  C. Ling,et al.  Results of a phase I dose escalation study in the treatment of inoperable non-small cell lung cancer , 2003 .

[37]  J Hanson,et al.  Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration. , 2001, International journal of radiation oncology, biology, physics.

[38]  K. Lam,et al.  Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging. , 1998, International journal of radiation oncology, biology, physics.

[39]  Kenneth E Rosenzweig,et al.  Evaluation of deep inspiration breath-hold lung treatment plans with Monte Carlo dose calculation. , 2002, International journal of radiation oncology, biology, physics.

[40]  R Mackie,et al.  A new approach to dose escalation in non-small-cell lung cancer. , 2001, International journal of radiation oncology, biology, physics.

[41]  M. V. van Herk,et al.  Physical aspects of a real-time tumor-tracking system for gated radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[42]  T. Guerrero,et al.  Acquiring 4D thoracic CT scans using a multislice helical method. , 2004, Physics in medicine and biology.

[43]  J. Mcaleer,et al.  Radical radiotherapy for inoperable non-small cell lung cancer: what factors predict prognosis? , 2000, Clinical oncology (Royal College of Radiologists (Great Britain)).

[44]  H Shirato,et al.  Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy. , 2000, International journal of radiation oncology, biology, physics.