The effect of implant modification: the low contact stress experience.

AIMS The aim of this study was to conduct the largest low contact stress (LCS) retrieval study to elucidate the failure mechanisms of the Porocoat and Duofix femoral component. The latter design was voluntarily recalled by the manufacturer. MATERIALS AND METHODS Uncemented LCS explants were divided into three groups: Duofix, Porocoat, and mixed. Demographics, polyethylene wear, tissue ingrowth, and metallurgical analyses were performed. RESULTS In 104 implants, a decrease in the odds of loosening and an increase in metallosis and tissue staining in the Duofix group relative to Porocoat group was detected (p = 0.028). There was an increased presence of embedded metallic debris in the Duofix group (p < 0.001). Decreased tissue ingrowth was associated with the Duofix surface (p < 0.001). The attached beads had reduced microhardness, indicative of adverse thermal processing, which resulted in bead shedding, particulate debris, and metallosis. CONCLUSION Hydroxyapatite coating of the LCS femoral component produced unexpected results and led to its recall. The root cause was likely a combination of retained alumina grit and a reduction in bead microhardness (mechanical strength) resulting in increased particle debris, metallosis, and early revision. The Duofix LCS femoral component was not equivalent to the Porocoat version despite its approval through the Food and Drug Administration (FDA) 510(k) equivalance approval process. Regulation of the introduction of modified existing devices needs to be improved and the Duofix LCS should have been considered to be a new device for which equivalence had not been demonstrated at the point of introduction. Cite this article: Bone Joint J 2019;101-B:1248-1255.

[1]  M. Inacio,et al.  Projected increase in total knee arthroplasty in the United States - an alternative projection model. , 2017, Osteoarthritis and cartilage.

[2]  A. Silman,et al.  The role of national registries in improving patient safety for hip and knee replacements , 2017, BMC Musculoskeletal Disorders.

[3]  J. Ross,et al.  How do Orthopaedic Devices Change After Their Initial FDA Premarket Approval? , 2016, Clinical orthopaedics and related research.

[4]  A. Aprato,et al.  Cementless total knee arthroplasty. , 2016, Annals of translational medicine.

[5]  A. Lombardi,et al.  New Total Knee Arthroplasty Designs: Do Young Patients Notice? , 2015, Clinical orthopaedics and related research.

[6]  Michael A Mont,et al.  Long-Term Implant Survivorship of Cementless Total Knee Arthroplasty: A Systematic Review of the Literature and Meta-Analysis , 2013, The Journal of Knee Surgery.

[7]  T. Brown,et al.  Comparison of cemented and uncemented fixation in total knee arthroplasty. , 2013, Orthopedics.

[8]  E. Swarts,et al.  What are the predictors for bead shedding in porous-coated hip and knee arthroplasties?: An implant retrieval study. , 2012, The Journal of arthroplasty.

[9]  Y. Youm,et al.  What have we learned from LCS mobile-bearing knee system? , 2010, Knee Surgery, Sports Traumatology, Arthroscopy.

[10]  S. Kurtz,et al.  Future Young Patient Demand for Primary and Revision Joint Replacement: National Projections from 2010 to 2030 , 2009, Clinical orthopaedics and related research.

[11]  F. Kennedy,et al.  Clinical wear measurement on low contact stress rotating platform knee bearings. , 2008, The Journal of arthroplasty.

[12]  Karon F Cook,et al.  The John Insall Award: Patient Expectations Affect Satisfaction with Total Knee Arthroplasty , 2006, Clinical orthopaedics and related research.

[13]  S. Reichenbach,et al.  Osteoarthritis: rational approach to treating the individual. , 2006, Best practice & research. Clinical rheumatology.

[14]  Gerard A Engh,et al.  Responsibilities when confronting a defective surgical implant. , 2003, Clinical orthopaedics and related research.

[15]  F. Buechel,et al.  Twenty-Year Evaluation of Meniscal Bearing and Rotating Platform Knee Replacements , 2001, Clinical orthopaedics and related research.

[16]  C. Bünger,et al.  Hydroxyapatite coating converts fibrous tissue to bone around loaded implants. , 1993, The Journal of bone and joint surgery. British volume.

[17]  C. Bünger,et al.  Tissue ingrowth into titanium and hydroxyapatite‐coated implants during stable and unstable mechanical conditions , 1992, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[18]  R G Geesink,et al.  Experimental and clinical experience with hydroxyapatite-coated hip implants. , 1989, Orthopedics.

[19]  A H Burstein,et al.  Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses. , 1983, Journal of biomedical materials research.