Three-phase short-circuit fault implementation in converter based transmission line emulator

A hardware test-bed (HTB) has been developed to realize power system emulation by mimicking the system components with universal three-phase voltage source converters (VSCs). The VSC-based transmission line emulator has also been successfully developed to flexibly represent interconnected ac lines under normal operating conditions. As the most serious short-circuit fault condition, the three-phase short-circuit fault emulation is essential for power system studies. This paper proposes a model to realize the three-phase short-circuit fault emulation within the emulated transmission line. At the same time, a combination method is proposed to eliminate the undesired transients caused by the current reference step changes while switching between the fault state and normal state.

[1]  Chika O. Nwankpa RECONFIGURABLE TRANSMISSION LINE MODEL FOR ANALOG POWER FLOW COMPUTATION , 2005 .

[2]  Kusum Shanthi,et al.  Modeling of power transmission lines for lightning back flashover analysis (A case study: 220kV Biyagama-Kotmale transmission line) , 2011, 2011 6th International Conference on Industrial and Information Systems.

[3]  Bo Liu,et al.  Control and implementation of converter based ac transmission line emulation , 2015, 2015 IEEE Applied Power Electronics Conference and Exposition (APEC).

[4]  Maamar Taleb,et al.  Performance of short transmission lines models , 2006, 2006 IEEE GCC Conference (GCC).

[5]  Leon M. Tolbert,et al.  Short circuit fault emulation by shunt connected voltage source converter , 2015, 2015 IEEE Energy Conversion Congress and Exposition (ECCE).

[6]  Bo Liu,et al.  Development, Demonstration, and Control of a Testbed for Multiterminal HVDC System , 2017, IEEE Transactions on Power Electronics.

[7]  Bo Liu,et al.  Hardware implementation of a four-terminal HVDC test-bed , 2015, 2015 IEEE Energy Conversion Congress and Exposition (ECCE).

[8]  Bo Liu,et al.  HVDC converter transformer saturation in hybrid AC/DC system caused by coupled transmission lines , 2017, 2017 IEEE Applied Power Electronics Conference and Exposition (APEC).

[9]  E. C. M. Costa,et al.  Development of a simplified transmission line model directly in the phase domain , 2012, 2012 IEEE Power and Energy Society General Meeting.

[10]  V. Dinavahi,et al.  Digital hardware emulation of universal machine and universal line models for real-time electromagnetic transient simulation , 2012, 2012 IEEE Power and Energy Society General Meeting.

[11]  V Dinavahi,et al.  Real-Time Nonlinear Transient Simulation Based on Optimized Transmission Line Modeling , 2011, IEEE Transactions on Power Systems.

[12]  Bo Liu,et al.  Design consideration of converter based transmission line emulation , 2016, 2016 IEEE Applied Power Electronics Conference and Exposition (APEC).

[13]  Jose R. Marti,et al.  Modelling of single-phase nonuniform transmission lines in electromagnetic transient simulations , 1997 .

[14]  Yuan Chen,et al.  FPGA-based real-time EMTP , 2009, 2009 IEEE Power & Energy Society General Meeting.

[15]  B. Gustavsen Frequency Dependent Transmission Line Modeling Utilizing Transposed Conditions , 2002, IEEE Power Engineering Review.

[16]  Leon M. Tolbert,et al.  Development of a hybrid emulation platform based on RTDS and reconfigurable power converter-based testbed , 2016, 2016 IEEE Applied Power Electronics Conference and Exposition (APEC).

[17]  Jing Wang,et al.  Regenerative power converters representation of grid control and actuation emulator , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[18]  S. Kurokawa,et al.  Simulations of electromagnetic transients in a transmission line using state variables , 2008, 2008 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America.