Calculating photon beam characteristics with Monte Carlo techniques.

This study describes the results from a simulation of a 10 MV photon beam from a medical linac using the BEAM code. To check the quality of the generated photon beam, the characteristics of this beam (depth dose curve, cross profiles, and output factors) have been calculated and compared to measured data. By splitting up the radiation head in two parts, the target section and the collimator section calculation times were long, but acceptable when aiming at phase space files containing some 5 million particles. Given the number of particles evaluated, the accuracy of all data was around 2%. Analysis of the phase space files for different field size supports results from previous studies about contaminant particles and sources for scattered radiation for photon beams from medical linacs. The total scatter output factor Scp as well as the collimator scatter output factor Sc have been calculated within 2% of measurements. Also, the ratio between dose at a reference point for the full scatter situation and the no-scatter situation has been calculated correctly. All depth dose curves and cross profiles have also been calculated correctly, although with only moderate statistics. Improvements are possible by increasing the number of particles in the simulations (up to 50 million for the largest field size) at least 4-8 times, although calculation times will increase with the same factor. Nevertheless, the method proved itself as reliable. Still, the accuracy should be improved to 1% or better. This is necessary as we plan to use Monte Carlo simulations to benchmark three-dimensional radiotherapy planning systems. By increasing the number of particles in the phase space files and subsequently increasing the number of particles in each simulation, this 1% accuracy will be achieved. The easy way to increase the number of particles in a simulation by increasing the number of times phase space files, which were already recycled ten times, are reused from ten times (this study) to 40 times or more will not work, as it introduces artifacts, especially in the cross profiles.

[1]  J W Wong,et al.  Photon dose calculation incorporating explicit electron transport. , 1995, Medical physics.

[2]  I. Kawrakow,et al.  3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC). , 1996, Medical physics.

[3]  P A Jursinic,et al.  Characteristics of secondary electrons produced by 6, 10 and 24 MV x-ray beams. , 1996, Physics in medicine and biology.

[4]  R Mohan,et al.  Energy and angular distributions of photons from medical linear accelerators. , 1985, Medical physics.

[5]  A Ahnesjö,et al.  Collimator scatter in photon therapy beams. , 1995, Medical physics.

[6]  K M Ayyangar,et al.  On compensator design for photon beam intensity-modulated conformal therapy. , 1998, Medical physics.

[7]  D. Followill,et al.  An empirical relationship for determining photon beam quality in TG-21 from a ratio of percent depth doses. , 1998, Medical physics.

[8]  A F Bielajew,et al.  A standard timing benchmark for EGS4 Monte Carlo calculations. , 1992, Medical physics.

[9]  B. Paliwal,et al.  On the cause of the variation in tissue-maximum ratio values with source-to-detector distance. , 1993, Medical physics.

[10]  A. Ahnesjö Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media. , 1989, Medical physics.

[11]  Alex F. Bielajew,et al.  Incorporation of single elastic scattering in the EGS4 Monte Carlo code system: tests of Molière theory , 1993 .

[12]  T. Mackie,et al.  A dual source photon beam model used in convolution/superposition dose calculations for clinical megavoltage x-ray beams. , 1997, Medical physics.

[13]  A Kosunen,et al.  Beam quality specification for photon beam dosimetry. , 1993, Medical physics.

[14]  T. Mackie,et al.  MMC--a high-performance Monte Carlo code for electron beam treatment planning. , 1995, Physics in medicine and biology.

[15]  T R Mackie,et al.  Calculating output factors for photon beam radiotherapy using a convolution/superposition method based on a dual source photon beam model. , 1997, Medical physics.

[16]  E L Chaney,et al.  A Monte Carlo study of accelerator head scatter. , 1994, Medical physics.

[17]  P E Metcalfe,et al.  Magnetic repulsion of linear accelerator contaminates. , 1996, Medical physics.

[18]  J. Venselaar,et al.  The determination of phantom and collimator scatter components of the output of megavoltage photon beams: measurement of the collimator scatter part with a beam-coaxial narrow cylindrical phantom. , 1991, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[19]  R Mohan,et al.  A Monte Carlo model of photon beams used in radiation therapy. , 1995, Medical physics.

[20]  M. Karlsson,et al.  Electron contamination in clinical high energy photon beams. , 1996, Medical physics.

[21]  P C Lee,et al.  Monte Carlo simulations of the differential beam hardening effect of a flattening filter on a therapeutic x-ray beam. , 1997, Medical physics.

[22]  P. Keall,et al.  Superposition dose calculation incorporating Monte Carlo generated electron track kernels. , 1996, Medical physics.

[23]  M Udale-Smith,et al.  Monte Carlo calculations of electron beam parameters for three Philips linear accelerators , 1992 .

[24]  G X Ding,et al.  Mean energy, energy-range relationships and depth-scaling factors for clinical electron beams. , 1996, Medical physics.

[25]  G X Ding,et al.  R50 as a beam quality specifier for selecting stopping-power ratios and reference depths for electron dosimetry. , 1996, Medical physics.

[26]  J. Cygler,et al.  Commissioning and quality assurance of treatment planning computers. , 1993, International journal of radiation oncology, biology, physics.

[27]  A. Trepp,et al.  Acquisition of the effective lateral energy fluence distribution for photon beam dose calculations by convolution models , 1991 .

[28]  G X Ding,et al.  Calculation of stopping-power ratios using realistic clinical electron beams. , 1995, Medical physics.

[29]  C. Ma,et al.  BEAM: a Monte Carlo code to simulate radiotherapy treatment units. , 1995, Medical physics.

[30]  C. Börgers Complexity of Monte Carlo and deterministic dose-calculation methods. , 1998, Physics in medicine and biology.