Postoperative Imaging of Bioabsorbable Anchors in Rotator Cuff Repair

Background: Bioabsorbable anchors may lead to osteolysis and cyst formation. However, the prevalence of these outcomes is not known for rotator cuff repairs. Purpose: To evaluate cyst formation after placement of bioabsorbable anchors for rotator cuff repairs and to verify whether bioabsorbable anchors degraded as intended and preserved bone stock for possible revision compared with metal anchors. The null hypothesis was that the rate and severity of cyst formation around the anchor are negligible. Study Design: Case series; Level of evidence, 4. Methods: Between April 2008 and November 2011, a total of 209 patients (85 men, 124 women) underwent rotator cuff repair with bioabsorbable suture anchors (113 with polylactic acid enantiomers [PLLA] and 96 with poly-D,L-lactide from L-lactide and D-lactide [PLDLA]); the patients underwent magnetic resonance imaging (MRI) evaluation more than 10 months after surgery. The fluid signal around the anchor on T2-weighted MRI scans was graded as follows: grade 0, no fluid around anchor; grade 1, minimal fluid around anchor; grade 2, local fluid around anchor; grade 3, fluid collection around entire length of anchor with cyst diameter less than twice the anchor diameter; and grade 4, cyst diameter larger than grade 3. The integrity of repairs was also evaluated. Results: Cysts were observed in 97 instances (46.4%). There were 41 grade 1 cases (19.6%), 16 grade 2 (7.7%), 22 grade 3 (10.5%), and 18 grade 4 (8.6%). Healing of repaired tendon was observed in 131 patients (62.7%). There was no statistical difference in healing rate between patients with and without cyst formation (66.1% vs 58.8%; P = .276). Altered anchor shape and absorption were not observed in most of the patients. However, in 12 patients (6 with PLLA and 6 with PLDLA anchors), T2-weighted scans showed that the signal intensity of anchors had changed since surgery, which could indicate that absorption had taken place; nonetheless, even in these 12 patients, anchors were clearly visible on T1-weighted scans. Conclusion: Osteolysis and cyst formation are common complications following the use of bioabsorbable anchors in rotator cuff repairs. Considering that adequate absorption of anchors and preservation of bone stock are the reasons for using bioabsorbable anchors, use of these anchors should be reconsidered because of possible interference with revision surgery.

[1]  R. Warren,et al.  Arthroscopic shoulder stabilization. A role for biodegradable materials. , 1993, Clinical orthopaedics and related research.

[2]  O. Böstman,et al.  Degradation and tissue replacement of an absorbable polyglycolide screw in the fixation of rabbit femoral osteotomies. , 1992, The Journal of bone and joint surgery. American volume.

[3]  G. Athwal,et al.  Osteolysis and arthropathy of the shoulder after use of bioabsorbable knotless suture anchors. A report of four cases. , 2006, The Journal of bone and joint surgery. American volume.

[4]  B. Zikria,et al.  Techniques for Suture Anchor Removal in Shoulder Surgery , 2010, The American journal of sports medicine.

[5]  Benjamin T. Busfield,et al.  Sterile pretibial abscess after anterior cruciate reconstruction from bioabsorbable interference screws: a report of 2 cases. , 2007, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[6]  M. Spoliti Glenoid osteolysis after arthroscopic labrum repair with a bioabsorbable suture anchor. , 2007, Acta orthopaedica Belgica.

[7]  O. Böstman,et al.  Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers. , 1990, The Journal of bone and joint surgery. British volume.

[8]  B. Lee,et al.  Delayed intra-articular inflammatory reaction due to poly-L-lactide bioabsorbable interference screw used in anterior cruciate ligament reconstruction. , 2008, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[9]  D. Mastrokalos,et al.  Allergic reaction to biodegradable interference poly-L-lactic acid screws after anterior cruciate ligament reconstruction with bone-patellar tendon-bone graft. , 2008, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[10]  P. Debeer,et al.  Delayed migration of a metal suture anchor into the glenohumeral joint. , 2010, Acta orthopaedica Belgica.

[11]  W. H. Warden,et al.  Ten-year magnetic resonance imaging follow-up of bioabsorbable poly-L-lactic acid interference screws after anterior cruciate ligament reconstruction. , 2008, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[12]  M. Slabaugh,et al.  Outcomes of type II superior labrum, anterior to posterior (SLAP) repair: prospective evaluation at a minimum two-year follow-up. , 2010, Journal of shoulder and elbow surgery.

[13]  Darren L. Johnson,et al.  Extensive Osteolysis after Rotator Cuff Repair with a Bioabsorbable Suture Anchor: A Case Report , 2005, The American journal of sports medicine.

[14]  J. Daigneault,et al.  Symptomatic interarticular migration of glenoid suture anchors. , 2000, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[15]  Freddie H. Fu,et al.  Hamstring anterior cruciate ligament reconstruction: a comparison of bioabsorbable interference screw and endobutton-post fixation. , 2004, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[16]  W S Pietrzak,et al.  Bioabsorbable Polymer Science for the Practicing Surgeon , 1997, The Journal of craniofacial surgery.

[17]  M. Baums,et al.  Intraosseous foreign body granuloma in rotator cuff repair with bioabsorbable suture anchor , 2010, Archives of Orthopaedic and Trauma Surgery.

[18]  M. Zlatkin MRI of the postoperative shoulder , 2002, Skeletal Radiology.

[19]  W. Dockery,et al.  Long-term absorption of poly-L-lactic Acid interference screws. , 2006, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[20]  D. Hutmacher,et al.  Scaffolds in tissue engineering bone and cartilage. , 2000, Biomaterials.

[21]  J. Hart,et al.  Bone Replacement of Fast-Absorbing Biocomposite Anchors in Arthroscopic Shoulder Labral Repairs , 2012, The American journal of sports medicine.

[22]  M A Collier,et al.  Bioabsorbable suture anchor (co-polymer 85/15 D,L lactide/glycolide) implanted in bone: correlation of physical/mechanical properties, magnetic resonance imaging, and histological response. , 1999, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[23]  R. Warren,et al.  An Arthroscopic Technique for Anterior Stabilization of the Shoulder with a Bioabsorbable Tack* , 1996, The Journal of bone and joint surgery. American volume.

[24]  B. Sennett,et al.  Poly-L/D-lactic acid anchors are associated with reoperation and failure of SLAP repairs. , 2011, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[25]  J. Oh,et al.  Prognostic factors affecting anatomic outcome of rotator cuff repair and correlation with functional outcome. , 2009, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[26]  P. Parizel,et al.  Reduction of metal artefacts in musculoskeletal MR imaging. , 2007, JBR-BTR : organe de la Societe royale belge de radiologie (SRBR) = orgaan van de Koninklijke Belgische Vereniging voor Radiologie.

[27]  William D Middleton,et al.  The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. , 2004, The Journal of bone and joint surgery. American volume.

[28]  A. Weiler,et al.  Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation: experimental study in sheep. , 1996, The Journal of bone and joint surgery. British volume.

[29]  Y. Rhee,et al.  The Factors Affecting the Clinical Outcome and Integrity of Arthroscopically Repaired Rotator Cuff Tears of the Shoulder , 2009, Clinics in orthopedic surgery.

[30]  N. Ghodadra,et al.  Complications of Bioabsorbable Suture Anchors in the Shoulder , 2012, The American journal of sports medicine.

[31]  U. Rydholm,et al.  Severe aseptic synovitis of the knee after biodegradable internal fixation. A case report. , 1992, Acta orthopaedica Scandinavica.

[32]  M. Provencher,et al.  Postsurgical Glenohumeral Arthritis in Young Adults , 2009, The American journal of sports medicine.

[33]  J. Ahn,et al.  Rotator cuff integrity after arthroscopic repair for large tears with less-than-optimal footprint coverage. , 2009, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[34]  Sang-Jin Shin,et al.  Arthroscopic removal of proud metallic suture anchors after Bankart repair , 2009, Archives of Orthopaedic and Trauma Surgery.

[35]  A. Wallace,et al.  Glenoid rim fracture in contact athletes with absorbable suture anchor reconstruction. , 2009, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[36]  W. Levine,et al.  Is the Etiology of Pretibial Cyst Formation After Absorbable Interference Screw Use Related to a Foreign Body Reaction? , 2011, Clinical orthopaedics and related research.

[37]  R. Cofield,et al.  Results of a second attempt at surgical repair of a failed initial rotator-cuff repair. , 1984, The Journal of bone and joint surgery. American volume.

[38]  J. Read,et al.  The natural history of a bioabsorbable interference screw used for anterior cruciate ligament reconstruction with a 4-strand hamstring technique. , 2005, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[39]  M. Baums,et al.  Intraarticular migration of a broken biodegradable interference screw after anterior cruciate ligament reconstruction , 2006, Knee Surgery, Sports Traumatology, Arthroscopy.

[40]  R. Arciero,et al.  Material properties and composition of soft-tissue fixation. , 2010, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.