Active Catheters for Neuroradiology

Surgeons performing endovascular interventions have high expectations with regard to the 15 improvement of their operating tools and, more specifically, of their catheters. Active catheters, in which the tip moves actively using shape memory alloy (SMA) actuators, constitute a promising approach. In this article, we review existing SMA-based active catheters present in the literature. We analyze their performances regarding the requirements imparted to neuroradiology. Then, we propose a new analytical model for predicting the 20 thermo-mechanical behavior of steerable catheters actuated through SMA wires. Particularly, we give an expression for the maximal achievable bending angle of the catheter tip. These results are finally applied to the design of single-use small-diameter active catheters especially devoted to neuroradiology. In particular, we present a 3.3-Fr catheter suited for navigating into the Willis’ polygon and for accurate positioning into aneurysmal cavities. 25

[1]  S. Shabalovskaya,et al.  On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys. , 1996, Bio-medical materials and engineering.

[2]  N. Munce,et al.  Conducting polymer based active catheter for minimally invasive interventions inside arteries , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[3]  Y. Ueda,et al.  Development of a microfine active bending catheter equipped with MIF tactile sensors , 1999, Technical Digest. IEEE International MEMS 99 Conference. Twelfth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.99CH36291).

[4]  M. Hirohata,et al.  Distal-tip shape-consistency testing of steam-shaped microcatheters suitable for cerebral aneurysm coil placement. , 2004, AJNR. American journal of neuroradiology.

[5]  Yoichi Haga,et al.  Batch fabricated flat meandering shape memory alloy actuator for active catheter , 2001 .

[6]  Emilie Marchandise,et al.  Thermal and hydrodynamic modelling of active catheters for interventional radiology , 2011, Computer methods in biomechanics and biomedical engineering.

[7]  H Mukai,et al.  Shape memory alloy catheter system for peroral pancreatoscopy using an ultrathin-caliber endoscope. , 1994, Endoscopy.

[8]  Koji Ikuta,et al.  Hydrodynamic Active Catheter with Multi Degrees of Freedom Motion , 2007 .

[9]  Masayoshi Esashi,et al.  A multilink active catheter with polyimide-based integrated CMOS interface circuits , 1999 .

[10]  Fred van Keulen,et al.  Design optimization of shape memory alloy active structures using the R-phase transformation , 2007, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[11]  江刺 正喜 Small diameter active catheter using shape memory alloy , 1998 .

[12]  Kazuhiro Kosuge,et al.  Micro catheter system with active guide wire , 1995, Proceedings of 1995 IEEE International Conference on Robotics and Automation.

[13]  Kazuhiro Kosuge,et al.  Micro active catheter system with multi degrees of freedom , 1994, Proceedings of the 1994 IEEE International Conference on Robotics and Automation.

[14]  Y. Haga,et al.  Small diameter active catheter using shape memory alloy , 1998, Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176.

[15]  Shuxiang Guo,et al.  Micro active guide wire catheter system , 1995, Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots.

[17]  M Piotin,et al.  Overlying Fluoroscopy and Preacquired CT Angiography for Road-Mapping in Cerebral Angiography , 2010, American Journal of Neuroradiology.

[18]  Jérôme Szewczyk,et al.  A practical approach to the design and control of active endoscopes , 2010 .

[19]  Yili Fu,et al.  Research on the axis shape of an active catheter , 2008, The international journal of medical robotics + computer assisted surgery : MRCAS.

[20]  Dominiek Reynaerts,et al.  The 'true' power of SMA micro-actuation , 2001 .

[21]  Seung-Ki Lee,et al.  Development of endovascular microtools , 2002 .

[22]  Tatsuo Arai,et al.  Development of a spiral structure for an active catheter-overview of the spiral structure and its kinematic configuration , 1999, Proceedings 1999 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human and Environment Friendly Robots with High Intelligence and Emotional Quotients (Cat. No.99CH36289).

[23]  M. Uchiyama,et al.  Active catheter with multi-link structure based on silicon micromachining , 1995, Proceedings IEEE Micro Electro Mechanical Systems. 1995.