Reliability and robustness of simultaneous absolute quantification of drug transporters, cytochrome P450 enzymes, and Udp-glucuronosyltransferases in human liver tissue by multiplexed MRM/selected reaction monitoring mode tandem mass spectrometry with nano-liquid chromatography.

Mass spectrometry (MS)-based multiplexed multiple reaction monitoring quantification of proteins has recently evolved as a versatile tool for accurate, absolute quantification of proteins. The purpose of this study was to examine the validity of the present method with regard to standard bioanalytical criteria for drug transporters, cytochrome P450 (CYP) enzymes and uridine 5'-diphospho-glucuronosyltransferases (UGTs). Membrane preparations from human liver tissue were used for target protein quantification. As a result, the determination coefficients (r(2)) of all targets were greater than 0.986. In the absence of matrix, inaccuracy values (expressed as % deviation) were -8.1% to 20.3%, whereas imprecision values (expressed as % coefficient of variation) were within 15.9%. In the presence of matrix, which consisted of digested plasma membrane fraction for transporters and digested microsomal membrane fraction for CYP enzymes and UGTs, respectively, the inaccuracy was -15.3%-8.1%, and the imprecision were within 18.9%. Sufficient sample stability of membrane fraction was shown for three freeze-thaw cycles, 32 days at -20°C, and in processed samples for 7 days at 10°C. In conclusion, this study demonstrated, for the first time, that the MS-based assay with nano-liquid chromatography provides adequate reliability and robustness for the quantification of selected drug transporters, P450 enzymes and UGTs.

[1]  A. Tsuji Impact of transporter-mediated drug absorption, distribution, elimination and drug interactions in antimicrobial chemotherapy , 2006, Journal of infection and chemotherapy : official journal of the Japan Society of Chemotherapy.

[2]  J. Ritter,et al.  Absolute quantification of human uridine-diphosphate glucuronosyl transferase (UGT) enzyme isoforms 1A1 and 1A6 by tandem LC-MS. , 2008, Drug metabolism letters.

[3]  S. Gygi,et al.  Correlation between Protein and mRNA Abundance in Yeast , 1999, Molecular and Cellular Biology.

[4]  R. Aebersold,et al.  Proteomics: the first decade and beyond , 2003, Nature Genetics.

[5]  Tetsuya Terasaki,et al.  Simultaneous absolute quantification of 11 cytochrome P450 isoforms in human liver microsomes by liquid chromatography tandem mass spectrometry with in silico target peptide selection. , 2011, Journal of pharmaceutical sciences.

[6]  Yuichi Sugiyama,et al.  Impact of Drug Transporter Studies on Drug Discovery and Development , 2003, Pharmacological Reviews.

[7]  T. Terasaki,et al.  Contribution of Carrier-Mediated Transport Systems to the Blood–Brain Barrier as a Supporting and Protecting Interface for the Brain; Importance for CNS Drug Discovery and Development , 2007, Pharmaceutical Research.

[8]  R. Aebersold,et al.  Mass Spectrometry and Protein Analysis , 2006, Science.

[9]  Na Li,et al.  LC-MS/MS mediated absolute quantification and comparison of bile salt export pump and breast cancer resistance protein in livers and hepatocytes across species. , 2009, Analytical chemistry.

[10]  Xinping Fang,et al.  LC-MS/MS approach for quantification of therapeutic proteins in plasma using a protein internal standard and 2D-solid-phase extraction cleanup. , 2007, Analytical chemistry.

[11]  David E. Misek,et al.  Discordant Protein and mRNA Expression in Lung Adenocarcinomas * , 2002, Molecular & Cellular Proteomics.

[12]  R. Aebersold,et al.  Mass spectrometry-based proteomics , 2003, Nature.

[13]  Tetsuya Terasaki,et al.  Quantitative Atlas of Membrane Transporter Proteins: Development and Application of a Highly Sensitive Simultaneous LC/MS/MS Method Combined with Novel In-silico Peptide Selection Criteria , 2008, Pharmaceutical Research.

[14]  Vinod P. Shah,et al.  Workshop/conference report—Quantitative bioanalytical methods validation and implementation: Best practices for chromatographic and ligand binding assays , 2007 .

[15]  Christoph H Borchers,et al.  Multiple Reaction Monitoring-based, Multiplexed, Absolute Quantitation of 45 Proteins in Human Plasma* , 2009, Molecular & Cellular Proteomics.

[16]  T. Terasaki,et al.  Quantitative membrane protein expression at the blood-brain barrier of adult and younger cynomolgus monkeys. , 2011, Journal of pharmaceutical sciences.

[17]  A. Monks,et al.  Glutathione-associated enzymes in the human cell lines of the National Cancer Institute Drug Screening Program. , 1996, Molecular pharmacology.

[18]  D. Lewis,et al.  57 varieties: the human cytochromes P450. , 2004, Pharmacogenomics.

[19]  Yuichi Sugiyama,et al.  Transporters as a determinant of drug clearance and tissue distribution. , 2006, European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences.

[20]  Takashi Suzuki,et al.  Quantitative targeted absolute proteomics of human blood–brain barrier transporters and receptors , 2011, Journal of neurochemistry.