Ultrasound Image-Guided Mapping of Endoscopic Views on a 3D Placenta Model: A Tracker-Less Approach

This work presents a framework for mapping of free-hand endoscopic views onto 3D anatomical model constructed from ultrasound images without the use of external trackers. It is non-disruptive in terms of existing surgical workflow as surgeons do not need to accommodate operational constraints associated with the use of additionally installed motion sensors or tracking systems. A passive fiducial marker is attached to the tip of the endoscope to create a geometric eccentricity that encodes the position and orientation of the camera. The relative position between the endoscope and the anatomical model under the ultrasound image reference frame is used to establish a texture map that overlays endoscopic views onto the surface of the model. This addresses operational challenges including the limited field-of-view (FOV) and the lack of 3D perspective associated with minimally invasive procedure. Experimental results show that average tool position and orientation errors are 1.32 mm and 1.6o respectively. The R.M.S. error of the overall image mapping obtained based on comparison of dimension of landmarks is 3.30 mm with standard deviation of 2.14 mm. The feasibility of the framework is also demonstrated through implementations on a phantom model.

[1]  Jon Hyett,et al.  Endoscopic laser coagulation in the management of severe twin‐to‐twin transfusion syndrome , 1998, British journal of obstetrics and gynaecology.

[2]  K. Cleary,et al.  Image-guided interventions: technology review and clinical applications. , 2010, Annual review of biomedical engineering.

[3]  Jon Hyett,et al.  Preliminary experience with endoscopic laser surgery for severe twin-twin transfusion syndrome , 1995 .

[4]  Ameet K. Jain,et al.  A Non-disruptive Technology for Robust 3D Tool Tracking for Ultrasound-Guided Interventions , 2011, MICCAI.

[5]  Hongen Liao,et al.  Fast image mapping of endoscopic image mosaics with three-dimensional ultrasound image for intrauterine fetal surgery , 2009, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[6]  Robert D. Howe,et al.  Real-time 3D ultrasound-based servoing of a surgical instrument , 2006, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006..

[7]  Olaf Dössel,et al.  World Congress on Medical Physics and Biomedical Engineering, September 7-12, 2009 Munich, Germany: Neuroengineering, Neural Systems, Rehabilitation and Prosthetics. Vol. 25/IX , 2009 .

[8]  Hongliang Ren,et al.  Passive Markers for Tracking Surgical Instruments in Real-Time 3-D Ultrasound Imaging , 2012, IEEE Transactions on Medical Imaging.

[9]  Mark Jenkinson,et al.  Non-local Shape Descriptor: A New Similarity Metric for Deformable Multi-modal Registration , 2011, MICCAI.

[10]  Robert D. Howe,et al.  GPU based real-time instrument tracking with three-dimensional ultrasound , 2007, Medical Image Anal..

[11]  Hongen Liao,et al.  Ultrasound image-based endoscope localization for minimally invasive fetoscopic surgery , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[12]  Hanmin Lee,et al.  Fetal endoscopic surgery: lessons learned and trends reviewed. , 2002, Journal of pediatric surgery.

[13]  R Rauskolb Fetoscopy--a new endoscopic approach. , 1979, Endoscopy.

[14]  Philippe C. Cattin,et al.  Mosaicing of Endoscopic Placenta Images , 2006, GI Jahrestagung.

[15]  A Fenster,et al.  An algorithm for automatic needle localization in ultrasound-guided breast biopsies. , 2000, Medical physics.

[16]  T. Anderson,et al.  Placental pathophysiology of the twin oligohydramnios-polyhydramnios sequence and the twin-twin transfusion syndrome. , 1998, Placenta.

[17]  Hongen Liao,et al.  GPU-based Fast 3D Ultrasound-Endoscope Image Fusion for Complex-Shaped Objects , 2009 .