Flexible Reconstruction and Correction of Unpredictable Motion from Stacks of 2D Images

We present a method to correct motion in fetal in-utero scan sequences. The proposed approach avoids previously necessary manual segmentation of a region of interest. We solve the problem of non-rigid motion by splitting motion corrupted slices into overlapping patches of finite size. In these patches the assumption of rigid motion approximately holds and they can thus be used to perform a slice-to-volume-based (SVR) reconstruction during which their consistency with the other patches is learned. The learned information is used to reject patches that are not conform with the motion corrected reconstruction in their local areas. We evaluate rectangular and evenly distributed patches for the reconstruction as well as patches that have been derived from super-pixels. Both approaches achieve on 29 subjects aged between 22–37 weeks a sufficient reconstruction quality and facilitate following 3D segmentation of fetal organs and the placenta.

[1]  Daniel Rueckert,et al.  Fast fully automatic brain detection in fetal MRI using dense rotation invariant image descriptors , 2014, 2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI).

[2]  K. Sandrasegaran,et al.  Fetal magnetic resonance imaging , 2006, Current opinion in obstetrics & gynecology.

[3]  J. Hair Multivariate data analysis , 1972 .

[4]  Simon K. Warfield,et al.  Robust Super-Resolution Volume Reconstruction From Slice Acquisitions: Application to Fetal Brain MRI , 2010, IEEE Transactions on Medical Imaging.

[5]  Colin Studholme,et al.  Registration-based approach for reconstruction of high-resolution in utero fetal MR brain images. , 2006, Academic radiology.

[6]  Daniel Rueckert,et al.  Motion Corrected 3D Reconstruction of the Fetal Thorax from Prenatal MRI , 2014, MICCAI.

[7]  Pascal Fua,et al.  SLIC Superpixels Compared to State-of-the-Art Superpixel Methods , 2012, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[8]  Mary A. Rutherford,et al.  Reconstruction of fetal brain MRI with intensity matching and complete outlier removal , 2012, Medical Image Anal..

[9]  Daniela Prayer,et al.  Fetal MRI: techniques and protocols , 2004, Pediatric Radiology.

[10]  Daniel Rueckert,et al.  Fast Volume Reconstruction from Motion Corrupted Stacks of 2D Slices , 2015, IEEE Transactions on Medical Imaging.

[11]  Daniel Rueckert,et al.  Automated fetal brain segmentation from 2D MRI slices for motion correction , 2014, NeuroImage.

[12]  Marco Nolden,et al.  The Medical Imaging Interaction Toolkit , 2005, Medical Image Anal..