Spreading a water droplet through filter paper on the metal substrate for surface-enhanced laser-induced breakdown spectroscopy.

To improve the quantitative analysis accuracy of an aqueous solution using surface-enhanced laser-induced breakdown spectroscopy (SENLIBS), the filter paper was used as a transmission medium by placing it onto the surface of a metallic substrate to make the microdroplet spreading more uniform in a fixed region of the substrate surface. The trace elements (Cu, Pb, Cd, and Cr) in an aqueous solution were detected successfully using this method. The results showed that the sample preparation repeatability of SENLIBS was noticeably improved with the aid of filter paper. Moreover, the limit of detection (LoD) values was similar to those without filter paper. Furthermore, the R2 values were improved from 0.6192~0.9321 to 0.9481~0.9766, the RMSECV values were decreased from 0.53~1.95 μg/mL to 0.33~1.06 μg/mL, and the average relative error (ARE) values were decreased from 8.96~22.31% to 4.28~14.37% with the aid of filter paper. This demonstrated that the use of filter paper could improve the quantitative analysis accuracy of SENLIBS by increasing the sample preparation repeatability.

[1]  Xiaoyan Zeng,et al.  Accuracy and stability improvement for meat species identification using multiplicative scatter correction and laser-induced breakdown spectroscopy. , 2018, Optics express.

[2]  H. Zeng,et al.  Laser-induced breakdown spectroscopic detection of trace level heavy metal in solutions on a laser-pretreated metallic target. , 2018, Talanta.

[3]  Wavelet-based interference correction for laser-induced breakdown spectroscopy , 2017 .

[4]  Yongfeng Lu,et al.  On-stream analysis of iron ore slurry using laser-induced breakdown spectroscopy. , 2017, Applied optics.

[5]  P. Veis,et al.  Determination of Metal Elements in Wine Using Laser-Induced Breakdown Spectroscopy (LIBS) , 2017, Applied spectroscopy.

[6]  R. Russo,et al.  Combination of atomic lines and molecular bands for uranium optical isotopic analysis in laser induced plasma spectrometry , 2017, Journal of Radioanalytical and Nuclear Chemistry.

[7]  Yongfeng Lu,et al.  Simultaneous determination of La, Ce, Pr, and Nd elements in aqueous solution using surface-enhanced laser-induced breakdown spectroscopy. , 2017, Talanta.

[8]  Ye Tian,et al.  Elemental analysis of powders with surface-assisted thin film laser-induced breakdown spectroscopy☆ , 2016 .

[9]  D. Dong,et al.  Comment on "Nanoparticle Enhanced Laser-Induced Breakdown Spectroscopy for Microdrop Analysis at subppm Level": Several Issues to Consider When Quantitatively Measuring Fluids Using Nanoparticle-Enhanced Laser-Induced Breakdown Spectroscopy. , 2016, Analytical chemistry.

[10]  L. Guo,et al.  Sensitive determinations of Cu, Pb, Cd, and Cr elements in aqueous solutions using chemical replacement combined with surface-enhanced laser-induced breakdown spectroscopy. , 2016, Optics express.

[11]  Yongfeng Lu,et al.  Determinations of trace boron in superalloys and steels using laser-induced breakdown spectroscopy assisted with laser-induced fluorescence. , 2016, Optics express.

[12]  S. Yalcin,et al.  Development and validation of a laser-induced breakdown spectroscopic method for ultra-trace determination of Cu, Mn, Cd and Pb metals in aqueous droplets after drying. , 2016, Talanta.

[13]  L. Guo,et al.  Background removal in soil analysis using laser- induced breakdown spectroscopy combined with standard addition method. , 2016, Optics express.

[14]  Yonghoon Lee,et al.  Spreading a water droplet on the laser-patterned silicon wafer substrate for surface-enhanced laser-induced breakdown spectroscopy , 2015 .

[15]  R. Russo,et al.  Femtosecond laser induced breakdown spectroscopy of Cu at the micron/sub-micron scale , 2015 .

[16]  R. Russo,et al.  A metric for evaluation of the image quality of chemical maps derived from LA-ICP-MS experiments , 2015 .

[17]  Yongfeng Lu,et al.  Analytical-performance improvement of laser-induced breakdown spectroscopy for steel using multi-spectral-line calibration with an artificial neural network , 2015 .

[18]  A. K. Rai,et al.  Evaluation of the prediction precision capability of partial least squares regression approach for analysis of high alloy steel by laser induced breakdown spectroscopy , 2015 .

[19]  J. Robinson,et al.  Femtosecond laser ablation multicollector ICPMS analysis of uranium isotopes in NIST glass , 2015 .

[20]  A. Canals,et al.  Hyphenation of single-drop microextraction with laser-induced breakdown spectrometry for trace analysis in liquid samples: a viability study , 2015 .

[21]  Meirong Dong,et al.  Liquid Sampling–Atmospheric Pressure Glow Discharge as a Secondary Excitation Source for Laser Ablation-Generated Aerosols: Parametric Dependence and Robustness to Particle Loading , 2015, Applied spectroscopy.

[22]  A. Canals,et al.  Dispersive liquid-liquid microextraction for metals enrichment: a useful strategy for improving sensitivity of laser-induced breakdown spectroscopy in liquid samples analysis. , 2015, Talanta.

[23]  R. K. Marcus,et al.  Investigation of spectrochemical matrix effects in the liquid sampling-atmospheric pressure glow discharge source , 2014 .

[24]  A. Canals,et al.  The determination of V and Mo by dispersive liquid–liquid microextraction (DLLME) combined with laser-induced breakdown spectroscopy (LIBS) , 2014 .

[25]  Heping Zeng,et al.  On the performance of laser-induced breakdown spectroscopy for direct determination of trace metals in lubricating oils , 2014 .

[26]  G. Galbács,et al.  An Assessment of the Potential of Laser-Induced Breakdown Spectroscopy (LIBS) for the Analysis of Cesium in Liquid Samples of Biological Origin , 2014, Applied spectroscopy.

[27]  Arnab Sarkar,et al.  Advancing the analytical capabilities of laser ablation molecular isotopic spectrometry for boron isotopic analysis , 2014 .

[28]  R. Russo,et al.  The inner lining of the reptilian brain: A heterogeneous cellular mosaic , 2014, Glia.

[29]  Ronger Zheng,et al.  Feasibility of wear metal analysis in oils with parts per million and sub-parts per million sensitivities using laser-induced breakdown spectroscopy of thin oil layer on metallic target , 2014 .

[30]  Erwan Negre,et al.  Indirect laser-induced breakdown of transparent thin gel layer for sensitive trace element detection , 2013 .

[31]  Miguel Ángel Aguirre,et al.  Elemental analysis by surface-enhanced Laser-Induced Breakdown Spectroscopy combined with liquid–liquid microextraction , 2013 .

[32]  M. Chaker,et al.  Quantitative analysis of metallic traces in water-based liquids by UV-IR double-pulse laser-induced breakdown spectroscopy , 2012 .

[33]  R. Sedev Surface tension, interfacial tension and contact angles of ionic liquids , 2011 .

[34]  Lewis Johnson,et al.  Development of a LIBS assay for the detection of Salmonella enterica serovar Typhimurium from food , 2011, Analytical and bioanalytical chemistry.

[35]  Z. Cui,et al.  Investigation of laser-induced breakdown spectroscopy of a liquid jet , 2010 .

[36]  M. Chaker,et al.  Improving laser-induced breakdown spectroscopy (LIBS) performance for iron and lead determination in aqueous solutions with laser-induced fluorescence (LIF) , 2009 .

[37]  A. K. Rai,et al.  Detection sensitivity of laser-induced breakdown spectroscopy for Cr II in liquid samples. , 2008, Applied optics.

[38]  A. Gajewski Contact angle and sessile drop diameter hysteresis on metal surfaces , 2008 .

[39]  M. Soylak,et al.  Solid-phase extraction of Mn(II), Co(II), Ni(II), Cu(II), Cd(II) and Pb(II) ions from environmental samples by flame atomic absorption spectrometry (FAAS). , 2007, Journal of hazardous materials.

[40]  M. Tabarant,et al.  Comparisons between LIBS and ICP/OES , 2006, Analytical and bioanalytical chemistry.

[41]  Akshaya Kumar,et al.  Detection of trace elements in liquids by laser-induced breakdown spectroscopy with a Meinhard nebulizer. , 2003, Applied optics.

[42]  Jagdish P. Singh,et al.  Optical emission from laser-induced breakdown plasma of solid and liquid samples in the presence of a magnetic field. , 2003, Applied optics.

[43]  Daniel Y. Kwok,et al.  Contact angle measurement and contact angle interpretation , 1999 .

[44]  F. Feuillebois,et al.  Influence of Surface Roughness on Liquid Drop Impact , 1998 .

[45]  E. Butler,et al.  Determination of arsenic species in sea-water by hydride generation atomic fluorescence spectroscopy , 1998 .

[46]  D. E. Sullivan Surface tension and contact angle of a liquid–solid interface , 1981 .

[47]  D. G. Biechler Determination of Trace Copper, Lead, Zinc, Cadmium, Nickel, and Iron in Industrial Waste Waters by Atomic Absorption Spectrometry after Ion Exchange Concentration on Dowex A-1. , 1965 .