Laser‐induced photoacoustic injury of skin: Effect of inertial confinement

Argon‐fluoride (ArF) excimer laser‐induced acoustic injury was confirmed by ablating the stratum corneum (s.c.) inertially confined by water in vivo. Hairless rats were irradiated through a quartz chamber with flowing distilled water or air and a 2.5 mm aperture. The laser was adjusted to deliver 150 mJ/cm2 at the skin surface for both conditions. Partial and complete ablation of the s.c. was achieved with 12 and 24 pulses, respectively. Immediate damage was assessed by the transmission electron microscopy. Partial ablation of the s.c. through air produced no damage, whereas partial ablation through water damaged skin to a mean depth of 114.5 ± 8.8 μm (±SD). Full thickness ablation of the s.c. through air and water produced damage zones measuring 192.2 ± 16.2 and 293.0 ± 71.6 μm, respectively (P<0.05). The increased depth of damage in the presence of inertial confinement provided by the layer of water strongly supports a photoacoustic mechanism of damage. The damage induced by partial ablation of the s.c. provides evidence that photochemical injury is not a significant factor in the damage at a depth because the retained s.c. acts as a partial barrier to diffusion of photochemical products. Combined with our previous studies, these experiments demonstrate that pressure transients are responsible for the deep damage seen with 193 nm ablation and that photoacoustic effects must be considered when using short‐pulse, high‐peak power lasers.

[1]  R. Srinivasan,et al.  Ablation of polymers and biological tissue by ultraviolet lasers. , 1986, Science.

[2]  S. Trokel,et al.  Excimer laser surgery of the cornea. , 1983, American journal of ophthalmology.

[3]  Rangaswamy Srinivasan,et al.  Nanosecond photoacoustic studies on ultraviolet laser ablation of organic polymers , 1986 .

[4]  P E Dyer,et al.  Far‐ultraviolet laser ablation of the cornea: Photoacoustic studies , 1987, Lasers in surgery and medicine.

[5]  F. Dunn,et al.  Comprehensive compilation of empirical ultrasonic properties of mammalian tissues. , 1978, The Journal of the Acoustical Society of America.

[6]  R R Krueger,et al.  High-speed photography of excimer laser ablation of the cornea. , 1987, Archives of ophthalmology.

[7]  S L Jacques,et al.  Controlled removal of human stratum corneum by pulsed laser. , 1987, The Journal of investigative dermatology.

[8]  R. Srinivasan,et al.  Ablation of liquid benzene by pulsed ultraviolet (248 or 308 nm) laser radiation , 1988 .

[9]  R. G. Jung,et al.  Quantitative assessment of laser‐induced stress waves generated at confined surfaces , 1974 .

[10]  R. Anderson,et al.  Fragmentation of biliary calculi with tunable dye lasers. , 1987, Gastroenterology.

[11]  D H Sliney,et al.  Laser photodisruptors. Damage mechanisms, instrument design and safety. , 1983, Ophthalmology.

[12]  F Hillenkamp,et al.  Excimer laser ablation of the cornea and lens. Experimental studies. , 1985, Ophthalmology.

[13]  C. Puliafito,et al.  Corneal endothelial injury in rabbits following excimer laser ablation at 193 and 248 nm. , 1986, Archives of ophthalmology.

[14]  S L Jacques,et al.  Putative photoacoustic damage in skin induced by pulsed ArF excimer laser. , 1988, The Journal of investigative dermatology.

[15]  G. Gorodetsky,et al.  Calorimetric and acoustic study of ultraviolet laser ablation of polymers , 1985 .

[16]  J. Marshall,et al.  An ultrastructural study of corneal incisions induced by an excimer laser at 193 nm. , 1985, Ophthalmology.

[17]  David A. Hutchins,et al.  Laser generated ultrasound at modified metal surfaces , 1981 .

[18]  J. Fujimoto,et al.  Time-resolved studies of Nd:YAG laser-induced breakdown. Plasma formation, acoustic wave generation, and cavitation. , 1985, Investigative ophthalmology & visual science.

[19]  Robert Lee Melcher,et al.  20‐MHz acoustic waves from pulsed thermoelastic expansions of constrained surfaces , 1977 .