Investigation on thermal comfort and energy conservation of local ventilation

This study evaluates the effect of temperature on thermal comfort and energy conservation by utilizing the previously used local ventilation air-conditioning mode. Three room temperatures (26°C, 28°C, 30°C (78.8°F, 82.4°F, 86°F)) and three LV temperatures (20°C, 26°C, 28°C (68°F, 78.8°F, 82.4°F)) were used. Eighteen subjects participated in the subjective experiment where they reported thermal sensation and thermal comfort. In addition, the energy consumption of a cooling system was calculated. The conditions of 26°Crt and 20°Clv (78.8°Frt and 68°Flv) (the room temperature of 26°C (78.8°F) combined with the LV temperature of 20°C (68°F)) and 30°Crt and 26°Clv (86°Frt and 78.8°Flv) were found to be in the comfortable range. The relationship between the thermal comfort improvement and energy conservation was indicated. The condition of 28°Crt and 26°Clv (82.4°Frt and 78.8°Flv) was assessed to be the most comfortable environment with moderate energy consumption. Compared with the traditional air conditioning mode, which creates a uniform environment by setting the room temperature to be 24°C (75.2°F), the utilization of LV could increase the comfortable room temperature to 30°C (86°F) and consume 24% less energy.

[1]  A. Melikov,et al.  The influence of heated or cooled seats on the acceptable ambient temperature range , 2007, Ergonomics.

[2]  Shinichi Tanabe,et al.  Thermal sensation and comfort with different task conditioning systems , 2007 .

[3]  Povl Ole Fanger,et al.  Findings of Personalized Ventilation Studies in a Hot and Humid Climate , 2005 .

[4]  Rongyi Zhao,et al.  Relationship between thermal sensation and comfort in non-uniform and dynamic environments , 2009 .

[5]  Eusébio Z. E. Conceição,et al.  Evaluation of Thermal Comfort in Slightly Warm Ventilated Spaces in Nonuniform Environments , 2006 .

[6]  P. Fanger,et al.  Human response to personalized ventilation and mixing ventilation. , 2004, Indoor air.

[7]  J. Baldasano,et al.  Preliminary Analysis Of Air Quality Data From Large Cities , 2001 .

[8]  C. Huizenga,et al.  Thermal sensation and comfort in transient non-uniform thermal environments , 2004, European Journal of Applied Physiology.

[9]  Li Lan,et al.  Application of statistical power analysis – How to determine the right sample size in human health, comfort and productivity research , 2010 .

[10]  Kim Bjarne Wittchen,et al.  Assessment of energy and natural resources conservation in office buildings using TOBUS , 2002 .

[11]  Fred Bauman,et al.  A field study of PEM (Personal Environmental Module) performance in Bank of America's San Francisco office buildings , 1997 .

[12]  A. Melikov Personalized ventilation. , 2004, Indoor air.

[13]  Anna Bogdan,et al.  Assessment of Thermal Comfort Using Personalized Ventilation , 2010 .

[14]  Edgar Erdfelder,et al.  A short tutorial of GPower , 2007 .

[15]  Hui Zhang,et al.  Partial- and whole-body thermal sensation and comfort— Part I: Uniform environmental conditions , 2006 .

[16]  Hui Zhang,et al.  Partial- and whole-body thermal sensation and comfort— Part I: Uniform environmental conditions , 2006 .

[17]  H. Zhang,et al.  Human thermal sensation and comfort in transient and non-uniform thermal environments , 2003 .

[18]  Chandra Sekhar,et al.  Ceiling mounted personalized ventilation system in hot and humid climate—An energy analysis , 2010 .

[19]  Thom Baguley,et al.  Understanding statistical power in the context of applied research. , 2004, Applied ergonomics.