Criterios para el refuerzo antisísmico de estructuras históricas

Architects and engineers have used a wide variety of repair or strengthening interventions to improve the structural response of ancient masonry structures. Some of these intervention techniques have been specifically implemented to upgrade the capacity of ancient structures to resist earthquakes. The use of these techniques must considerer the action on the original structure, and by the way they affect the integrity and the authenticity of the original materials and the structural features. The purpose of the present document is to review the actual criteria of the strengthening solutions used in restoration of historical structures.

[1]  I. Internacional Carta de Venecia: Carta Internacional Sobre la Conservación y la Restauración de Monumentos y Sitios. (1964) , 2012 .

[2]  Qingju Liu,et al.  Advanced design of Chinese traditional materials for the conservation of historic stone buildings , 2011 .

[3]  Paulo B. Lourenço,et al.  A Document Management System for the Conservation of Cultural Heritage Buildings , 2010 .

[4]  Vlatko Bosiljkov,et al.  Iconography : An integrated diagnostic approach for the assessment of historic masonry structures , 2010 .

[5]  Fernando Peña Mondragón,et al.  ESTRATEGIAS PARA EL MODELADO Y EL ANÁLISIS SÍSMICO DE ESTRUCTURAS HISTÓRICAS , 2010 .

[6]  E. Ganniari-Papageorgiou,et al.  Joining Fragmented Epistyles Using Threaded Titanium Bars: A Numerical Analysis , 2009 .

[7]  Terrence F. Paret,et al.  Using traditional and innovative approaches in the seismic evaluation and strengthening of a historic unreinforced masonry synagogue , 2008 .

[8]  Carmelo Gentile,et al.  Ambient vibration testing and structural evaluation of an historic suspension footbridge , 2008, Adv. Eng. Softw..

[9]  Chiara Calderini,et al.  Use of Reinforced Concrete in Preservation of Historic Buildings: Conceptions and Misconceptions in the Early 20th Century , 2008 .

[10]  Antonella Saisi,et al.  Non-Destructive Testing Techniques Applied for Diagnostic Investigation: Syracuse Cathedral in Sicily, Italy , 2007 .

[11]  Maria Rosa Valluzzi,et al.  On the vulnerability of historical masonry structures: analysis and mitigation , 2007 .

[12]  Agustín Orduña Bustamante,et al.  Evaluación sísmica de construcciones históricas de mampostería: comparación de tres modelos de análisis , 2007 .

[13]  M. Corradi,et al.  Confinement of brick masonry columns with CFRP materials , 2007 .

[14]  Roberto Meli,et al.  Criteria and Experiences on Structural Rehabilitation of Stone Masonry Buildings in Mexico City , 2007 .

[15]  Paulo B. Lourenço,et al.  Recommendations for restoration of ancient buildings and the survival of a masonry chimney , 2006 .

[16]  Antonio Borri,et al.  New Materials for Strengthening and Seismic Upgrading Interventions , 2002 .

[17]  Enrico Quagliarini,et al.  Rehabilitation and consolidation of high-value camorcanna” vaults with FRP , 2006 .

[18]  George G. Penelis,et al.  Structural restoration of historical buildings in seismic areas , 2002 .