Coordinated Control Strategy of CU-MTDC under Abnormal Conditions Considering Power Supply Security

The coastal urban multi-terminal DC (CU-MTDC) is a prospective solution for enhancing the power supply security of the coastal urban power (CUP) grid and integrating the large-scale offshore wind farm. However, the large DC disturbances may significantly impact the CUP power supply security. The existing DC unbalanced power distribution methods are difficult to be applied in the CU-MTDC because of the complicated optimization process and the expansion of the influence range of a DC fault. To solve the above problems, this paper proposes a coordinated control strategy of CU-MTDC under abnormal conditions. First, calculation principles for the active power reference of center coastal urban power (CCUP) grid converters are proposed. Second, a DC unbalanced power coordinated distribution strategy under abnormal conditions is used based on the dynamic priority control to ensure power supply security of the critical AC lines. Third, the controller parameters of CCUP grid converters are calculated. Through a simple control process, the number of the regulation converters is dynamically scheduled according to the DC unbalanced power. The DC fault influence range on the urban power grid can be limited in a sufficiently small area. Simulation verified the effectiveness of the proposed control strategy.

[1]  Xi Zhang,et al.  Alleviating congestion of hybrid urban grid by VSC-control and AC-line switching , 2019 .

[2]  Gilsoo Jang,et al.  Modified reactive power allocation strategy for large-scale offshore wind turbine considering subsystem configuration , 2020 .

[3]  Wei-Jen Lee,et al.  VSC-MTDC System Integrating Offshore Wind Farms Based Optimal Distribution Method for Financial Improvement on Wind Producers , 2019, 2018 IEEE Industry Applications Society Annual Meeting (IAS).

[4]  Alvaro Luna,et al.  Hierarchical Control of HV-MTDC Systems With Droop-Based Primary and OPF-Based Secondary , 2015, IEEE Transactions on Smart Grid.

[5]  Jiang Xun,et al.  Locating and sizing of partition flexible interconnection converter station in large urban power grids , 2019 .

[6]  Wenjuan Du,et al.  Minimization of Transmission Loss in Meshed AC/DC Grids With VSC-MTDC Networks , 2013, IEEE Transactions on Power Systems.

[7]  Qian Xu,et al.  Optimized Power Redistribution of Offshore Wind Farms Integrated VSC-MTDC Transmissions After Onshore Converter Outage , 2017, IEEE Transactions on Industrial Electronics.

[8]  Jiuping Pan,et al.  A Station-Hybrid HVDC System Structure and Control Strategies for Cross-Seam Power Transmission , 2021, IEEE Transactions on Power Systems.

[9]  Yu Zheng,et al.  Hierarchical SCOPF Considering Wind Energy Integration Through Multiterminal VSC-HVDC Grids , 2017, IEEE Transactions on Power Systems.

[10]  Meiyan Wang,et al.  Operation Modes and Combination Control for Urban Multivoltage-Level DC Grid , 2018, IEEE Transactions on Power Delivery.

[11]  Jun Cao,et al.  An Improved Corrective Security Constrained OPF for Meshed AC/DC Grids With Multi-Terminal VSC-HVDC , 2016, IEEE Transactions on Power Systems.

[12]  Jiuping Pan,et al.  A Subtransmission Metropolitan Power Grid: Using High-Voltage dc for Enhancement and Modernization , 2019, IEEE Power and Energy Magazine.

[13]  Zhijie Liu,et al.  Coordination control for multi-voltage-level dc grid based on the dc–dc converters , 2020 .

[14]  Ying Sun,et al.  A Coordination Control Strategy of Voltage-Source-Converter-Based MTDC for Offshore Wind Farms , 2015 .

[15]  Lina Bertling Tjernberg,et al.  A New Approach for Benefit Evaluation of Multiterminal VSC–HVDC Using A Proposed Mixed AC/DC Optimal Power Flow , 2014, IEEE Transactions on Power Delivery.

[16]  Linquan Bai,et al.  Key technologies for flexible interconnection in urban power grid and pilot demonstration , 2018 .

[17]  Kun Yu,et al.  The Control and Analysis of Self-Healing Urban Power Grid , 2012, IEEE Transactions on Smart Grid.

[18]  Li Zhiguo Analysis on System Characteristics After Incorporation of ±320 kV/1000 MW VSC-HVDC into Dalian Power Grid , 2013 .

[19]  Dirk Van Hertem,et al.  Ancillary Services in Electric Power Systems with HVDC Grids , 2015 .