Dynamic Time Over Threshold Method

The time over threshold (TOT) method has several advantages over direct pulse height analysis based on analog to digital converters (ADCs). A key advantage is the simplicity of the conversion circuit which leads to a high level of integration and a low power consumption. The TOT technique is well suited to build multi-channel readout systems for pixelated detectors as described in our previous work that also exploits the Pulse Width Modulation (PWM) method. The main limitation of the TOT technique is that the relation between the input charge to be measured and the width of the encoded pulse is strongly non-linear. Dynamic range limitation is also an issue. To address these aspects, we propose a new time over threshold conversion circuit where the threshold of the comparator is dynamically changed instead of being constant. We call this scheme the “dynamic TOT method”. We show that it improves linearity and dynamic range. It also shortens the duration of measured pulses leading to higher counting rates. We present a short analysis that explains how the ideal linear input charge to TOT transfer function can theoretically be obtained. We describe the results obtained with a test circuit built from discrete components and present several of the spectrums obtained with crystal detectors and a radioactive source. The proposed method can be used for applications like Positron Emission Tomography (PET) that require moderate energy resolution.

[1]  P. O'Connor,et al.  Front-end electronics for the RatCAP mobile animal PET scanner , 2004, IEEE Transactions on Nuclear Science.

[2]  W W Moses,et al.  A Multi-Threshold Sampling Method for TOF PET Signal Processing. , 2009, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment.

[3]  I. Kipnis,et al.  A time-over-threshold machine: the readout integrated circuit for the BABAR Silicon Vertex Tracker , 1997 .

[4]  H. Murayama,et al.  Novel front-end pulse processing scheme for PET system based on pulse width modulation and pulse train method , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[5]  P. Lecoq,et al.  A Time-Based Front End Readout System for PET & CT , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[6]  H. Murayama,et al.  A 12-channel CMOS preamplifier-shaper-discriminator ASIC for APD and gas counters , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[7]  H. Takahashi,et al.  A new multi-level time over threshold method for energy resolving multi-channel systems , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[8]  W. W. Moses,et al.  Empirical observation of resolution degradation in positron emission tomographs utilizing block detectors , 1994 .