Measurements and Analysis of a High-Brightness Electron Beam Collimated in a Magnetic Bunch Compressor

A collimator located in a magnetic bunch compressor of a linear accelerator driven x-ray free electron laser has many potential applications, such as the removal of horns in the current distribution, the generation of ultrashort beams, and as a diagnostic of the beam slice emittance. Collective effects, however, are a major concern in applying the technique. Systematic measurements of emittance and analysis were performed using a collimator in the first bunch compressor of the Linac Coherent Light Source (LCLS). In the nominal, undercompressed configuration using the collimator we find that the y emittance (nonbending plane) is not increased, and the x emittance (in the bending plane) is increased by about 25%, in comparison to the injector emittance. From the analysis we conclude that the parasitic effects associated with this method are dominated by coherent synchrotron radiation (CSR), which causes a “systematic error” for measuring slice emittance at the bending plane using the collimation method. In general, we find good agreement between the measurements and simulations including CSR. However, for overcompressed beams at smaller collimator gaps, an extra emittance increase is found that does not agree with 1D simulations and is not understood.

[1]  J. Wu,et al.  Commissioning the Linac Coherent Light Source injector , 2008 .

[2]  T. Raubenheimer Estimates of Emittance Dilution and Stability in High-Energy Linear Accelerators , 2000 .

[3]  C. Bostedt,et al.  Femtosecond x-ray pulse length characterization at the Linac Coherent Light Source free-electron laser , 2011 .

[4]  Rui Li Curvature-induced bunch self-interaction for an energy-chirped bunch in magnetic bends , 2008 .

[5]  P. Emma,et al.  CSR WAKE FOR A SHORT MAGNET IN ULTRARELATIVISTIC LIMIT , 2002 .

[6]  Michael Borland,et al.  Simple method for particle tracking with coherent synchrotron radiation , 2001 .

[7]  M. Dohlus,et al.  Impact of Optics on CSR-Related Emittance Growth in Bunch Compressor Chicanes , 2005, Proceedings of the 2005 Particle Accelerator Conference.

[8]  D. Ratner,et al.  First lasing and operation of an ångstrom-wavelength free-electron laser , 2010 .

[9]  D. Ratner,et al.  Measurements of the linac coherent light source laser heater and its impact on the x-ray free-electron laser performance , 2010 .

[10]  Pradeep Mitra Ecspe,et al.  REPORT NO , 2001 .

[11]  W. Schlotter,et al.  Experimental demonstration of a soft x-ray self-seeded free-electron laser. , 2015, Physical review letters.

[12]  G. Stupakov,et al.  Optical Approximation in the Theory of Geometric Impedance , 2007, physics/0703171.

[13]  F. Zhou,et al.  Emittance Growth and Energy Loss due to Coherent Synchrotron Radiation in a bunch compressor , 2000 .

[14]  Henrik Loos,et al.  Observation of Coherent Optical Transition Radiation in the LCLS Linac , 2008 .

[15]  I. Cudin,et al.  Electron slicing for the generation of tunable femtosecond soft x-ray pulses from a free electron laser and slice diagnostics , 2013 .

[16]  Impedance calculations of nonaxisymmetric transitions using the optical approximation , 2007, physics/0703188.

[17]  T. Ishikawa,et al.  A compact X-ray free-electron laser emitting in the sub-ångström region , 2012, Nature Photonics.