Airflow Characteristics at the Breathing Zone of a Seated Person: Passive Control over the Interaction of the Free Convection Flow and Locally Applied Airflow from Front for Personalized Ventilation Application

A method for active control over the interaction between the free convection flow around occupant‘s body and locally applied airflow from front on the velocity field at the breathing zone of a seated person was studied. A workplace equipped with personalised ventilation (PV) generating flow from front/above against the face of a thermal manikin with realistic body shape and surface temperature distribution (used to resemble a seated human body) was set in a climate chamber (4.70 m x 1.62 m x 2.60 m). The air temperature in the chamber was kept at 20 C. Ceiling diffuser supplied ventilation air at 15 l/s. The PV air was supplied isothermally at 4, 6 or 8 L/s. The PV diffuser with diameter 0.18 m, was located at distance 0.4 m from the face of the manikin. The distance between the lower chest of the manikin and the front edge of the desk was 0.1 m. Box with 6 small computer fans (suction box) was installed below the table board, above the thighs of the manikin, and was used to exhaust the air of the free convection flow coming from the lower body parts of the manikin. The velocity field at the breathing zone was measured with Particle Image Velocimetry consisting of a dual cavity laser and two CCD cameras. The maximum absolute mean velocity measured in the convective layer at the mouth of the manikin was 0.20 m/s and was reduced to 0.09 m/s when the suction box was used. Thus the weakend boundary layer can be penetrated by the PV flow at the lowered velocity. The use of the suction box and the PV at 4 L/s resulted in the same velocity at the breathing zone as when only PV was used at 6 L/s. The maximum absolute mean velocity measured at the breathing zone with the control and the PV at 8 L/s was 0.35 m/s.

[1]  A. Melikov,et al.  Improved Performance of Personalized Ventilation by Control of the Convection Flow around Occupant Body , 2009 .

[2]  Povl Ole Fanger,et al.  Human Response to Five Designs of Personalized Ventilation , 2006 .

[3]  Simon Meier,et al.  VENTILATION FOR BUILDINGS: DESIGN CRITERIA FOR THE IN- DOOR ENVIRONMENT - A NEW INITIATIVE , 2000 .

[4]  E. Lavernia,et al.  An experimental investigation , 1992, Metallurgical and Materials Transactions A.

[5]  Hao Jiang,et al.  Bed with Integrated Personalized Ventilation for Minimizing Cross Infection , 2007 .

[6]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[7]  Arsen Krikor Melikov,et al.  Seat headrest-incorporated personalized ventilation: Thermal comfort and inhaled air quality , 2012 .

[8]  Convective Heat Loss from the Human Body , 1976 .

[9]  A. Melikov,et al.  Personalized ventilation: evaluation of different air terminal devices , 2002 .

[10]  Henrik Brohus,et al.  Proceedings of Indoor Air 2008 , 2008 .

[11]  A. Melikov,et al.  Performance of “ductless” personalized ventilation in conjunction with displacement ventilation: Impact of disturbances due to walking person(s) , 2010 .

[12]  John F. Dannenhoffer,et al.  Experimental investigation of reduced-mixing personal ventilation jets , 2009 .

[13]  Raymond P. Clark,et al.  Some aspects of the airborne transmission of infection , 2009, Journal of The Royal Society Interface.

[14]  A. Melikov Personalized ventilation. , 2004, Indoor air.

[15]  Baoming Li,et al.  Airflow characteristics at the surface of manure in a storage pit affected by ventilation rate, floor slat opening, and headspace height , 2009 .

[16]  Arsen Krikor Melikov,et al.  Personalized ventilation: air terminal devices with high efficiency , 2003 .