Intra-aneurysmal flow with helix and mesh stent placement across side-wall aneurysm pore of a straight parent vessel.

Pulsatile flow fields in a cerebrovascular side-wall aneurysm model with a wide ostium after stenting are presented in terms of particle tracking velocimetry measurements and flow visualization. Among the stent parameters the shape, helix versus mesh, was selected to study its effect on the changes of intraaneurysmal hemodynamics for the reference of minimally invasive endovascular aneurysm treatment. The blocking ratio of the stents was fixed at 30%. The Womersley number was 3.9 and the mean, peak, and minimal Reynolds numbers based on the bulk average velocity and diameter of the parent vessel were 600, 850, and 300, respectively. Four consecutive flow-rate phases were selected to characterize the intra-aneurysmal flow. The results are characterized in terms of velocity vector field, regional average velocity, and intra-aneurysmal vorticity/circulation/wall shear stress. It is found that the hemodynamic features inside the aneurysm alter markedly with the shape of the stent and the size of the orifice. Both stents investigated induce favorable changes in the intra-aneurysmal flow stasis as well as direction and undulation of wall shear stresses. A comparison of the results of the helix to mesh stent shows that the former is more favorable for endovascular treatment.

[1]  Y. Cho,et al.  Intracranial aneurysms: flow analysis of their origin and progression. , 1992, AJNR. American journal of neuroradiology.

[2]  Baruch B. Lieber,et al.  Particle Image Velocimetry Assessment of Stent Design Influence on Intra-Aneurysmal Flow , 2002, Annals of Biomedical Engineering.

[3]  H Handa,et al.  Stiffness and elastic behavior of human intracranial and extracranial arteries. , 1980, Journal of biomechanics.

[4]  A. Wakhloo,et al.  Modeling of flow in a straight stented and nonstented side wall aneurysm model. , 1997, Journal of biomechanical engineering.

[5]  D. L. Fry Certain Histological and Chemical Responses of the Vascular Interface to Acutely Induced Mechanical Stress in the Aorta of the Dog , 1969, Circulation research.

[6]  J. L. Counord,et al.  In vitro study of haemodynamics in a giant saccular aneurysm model: influence of flow dynamics in the parent vessel and effects of coil embolisation , 1994, Neuroradiology.

[7]  B Lane,et al.  Stent placement for arterial and venous cerebrovascular disease: preliminary experience. , 1994, Radiology.

[8]  M. P. Judkins,et al.  Transluminal Treatment of Arteriosclerotic Obstruction: Description of a New Technic and a Preliminary Report of Its Application , 1964, Circulation.

[9]  D. L. Fry Acute Vascular Endothelial Changes Associated with Increased Blood Velocity Gradients , 1968, Circulation research.

[10]  M. Crompton THE PATHOGENESIS OF CEREBRAL INFARCTION FOLLOWING THE RUPTURE OF CEREBRAL BERRY ANEURYSMS. , 1964, Brain : a journal of neurology.

[11]  T CRAWFORD,et al.  SOME OBSERVATIONS ON THE PATHOGENESIS AND NATURAL HISTORY OF INTRACRANIAL ANEURYSMS , 1959, Journal of neurology, neurosurgery, and psychiatry.

[12]  J Haberstroh,et al.  Self-expanding and balloon-expandable stents in the treatment of carotid aneurysms: an experimental study in a canine model. , 1994, AJNR. American journal of neuroradiology.

[13]  W. C. Chang,et al.  LDV measurements in lateral model aneurysms of various sizes , 1997 .

[14]  W. D. Kingery,et al.  Introduction to Ceramics , 1976 .

[15]  T. Liou,et al.  Flowfields in lateral aneurysm models arising from parent vessels with different curvatures using PTV , 1997 .

[16]  G. Ferguson,et al.  Comparison of the elastic properties of human intracranial arteries and aneurysms. , 1972, Canadian journal of physiology and pharmacology.

[17]  J Suzuki,et al.  Clinicopathological study of cerebral aneurysms. Origin, rupture, repair, and growth. , 1978, Journal of neurosurgery.

[18]  Joel L. Berry,et al.  Experimental and Computational Flow Evaluation of Coronary Stents , 2000, Annals of Biomedical Engineering.

[19]  K. Perktold,et al.  Hemodynamics in rigid and distensible saccular aneurysms: a numerical study of pulsatile flow characteristics. , 1993, Biorheology.

[20]  C M Strother,et al.  Computer modeling of intracranial saccular and lateral aneurysms for the study of their hemodynamics. , 1995, Neurosurgery.

[21]  C M Strother,et al.  Flow dynamics of lateral carotid artery aneurysms and their effects on coils and balloons: an experimental study in dogs. , 1992, AJNR. American journal of neuroradiology.

[22]  G. Ferguson Physical factors in the initiation, growth, and rupture of human intracranial saccular aneurysms. , 1972, Journal of neurosurgery.