T1 quantification with inversion recovery TrueFISP

A snapshot FLASH sequence can be used to acquire the time course of longitudinal magnetization during its recovery after a single inversion pulse. However, excitation pulses disturb the exponential recovery of longitudinal magnetization and may produce systematic errors in T1 estimations. In this context the possibility of using the TrueFISP sequence to detect the recovery of longitudinal magnetization for quantitative T1 measurements was examined. Experiments were performed on different Gd‐doped water phantoms and on humans. T1 values derived from inversion recovery TrueFISP were in excellent agreement with the single‐point method even for flip angles up to 50°. In terms of T1 accuracy and SNR, the proposed method seems to be superior to the conventional inversion recovery snapshot FLASH technique. Magn Reson Med 45:720–723, 2001. © 2001 Wiley‐Liss, Inc.

[1]  Jürgen Hennig,et al.  Echoes—how to generate, recognize, use or avoid them in MR‐imaging sequences. Part II: Echoes in imaging sequences , 1991 .

[2]  E D Becker,et al.  Driven equilibrium Fourier transform spectroscopy. A new method for nuclear magnetic resonance signal enhancement. , 1969, Journal of the American Chemical Society.

[3]  A. Crawley,et al.  A comparison of one‐shot and recovery methods in T1 imaging , 1988, Magnetic resonance in medicine.

[4]  William H. Press,et al.  Numerical recipes in C , 2002 .

[5]  P. Bendel,et al.  An analysis of fast imaging sequences with steady‐state transverse magnetization refocusing , 1988, Magnetic resonance in medicine.

[6]  D Matthaei,et al.  Inversion recovery snapshot FLASH MR imaging. , 1989, Journal of computer assisted tomography.

[7]  David T. Pegg,et al.  Uniform sample excitation with surface coils for in vivo spectroscopy by adiabatic rapid half passage , 1986 .

[8]  Becker Ed,et al.  Driven equilibrium Fourier transform spectroscopy. A new method for nuclear magnetic resonance signal enhancement. , 1969 .

[9]  M. S. Silver,et al.  Highly selective {π}/{2} and π pulse generation , 1984 .

[10]  G. Bodenhausen,et al.  Principles of nuclear magnetic resonance in one and two dimensions , 1987 .

[11]  D. Look,et al.  Time Saving in Measurement of NMR and EPR Relaxation Times , 1970 .

[12]  J. Hogg Magnetic resonance imaging. , 1994, Journal of the Royal Naval Medical Service.

[13]  SNR improvement in NMR microscopy using DEFT , 1988 .

[14]  R Deichmann,et al.  T1 maps by K-space reduced snapshot-FLASH MRI. , 1992, Journal of computer assisted tomography.

[15]  A. Haase,et al.  Snapshot flash mri. applications to t1, t2, and chemical‐shift imaging , 1990, Magnetic resonance in medicine.

[16]  S. Patz,et al.  Some factors that influence the steady state in steady-state free precession. , 1988, Magnetic resonance imaging.