Comparing image quality of single- and dual-energy computed tomography of the brain

Purpose Weighted average dual-energy computed tomography (DE-CT) reconstructions are considered a proxy of standard CT images of the brain, recommended for routine clinical use and used as a reference standard in DE-CT research. However, their image quality has not been assessed, which was the aim of our study. Methods Images from 81 consecutive patients who underwent both non-contrast single-energy (SE)-CT and DE-CT of the brain on the same scanner were retrospectively evaluated. Attenuation values (HU) and SD of grey matter/white matter (GM/WM) pairs, along with SD in the posterior fossa and subcalvarial region were measured. Four readers evaluated image noise, GM/WM contrast, posterior fossa and subcalvarial artefacts, as well as overall image quality. Results Weighted average DE-CT GM and WM HU were significantly lower and noise higher compared to SE-CT (GM HU 36.46 v. 41.82; WM HU 28.18 v. 29.94; GM SD 2.93 v. 2.49; and WM SD 3.16 v. 2.44, all p < 0.0001). After correcting the measured SE-CT noise for 37% higher acquisition dose, DE-CT GM noise became significantly lower (2.93 v. 3.11, p = 0.0121). Measured and dose corrected SE-CT GM/WM contrast-to-noise ratio was superior to weighted average DE-CT (3.42 and 2.74 v. 1.95, both p < 0.0001). Weighted average DE-CT had significantly less artifacts on qualitative analysis. Conclusion Weighted average DE-CT images of the brain yield less artefacts at 37% dose reduction and lower noise at SE-CT equivalent dose. Dose-adjusted GM/WM contrast-to-noise ratio of weighted average DE-CT with 0.4 weighting factor remains inferior to SE-CT images.

[1]  Kuni Ohtomo,et al.  Preliminary report on virtual monochromatic spectral imaging with fast kVp switching dual energy head CT: comparable image quality to that of 120-kVp CT without increasing the radiation dose , 2013, Japanese Journal of Radiology.

[2]  Sabee Molloi,et al.  Effect of area x-ray beam equalization on image quality and dose in digital mammography. , 2004, Physics in medicine and biology.

[3]  C. Claussen,et al.  Noise-optimized virtual monoenergetic images and iodine maps for the detection of venous thrombosis in second-generation dual-energy CT (DECT): an ex vivo phantom study , 2015, European Radiology.

[4]  Jian Ying Li,et al.  High-Definition CT Gemstone Spectral Imaging of the Brain: Initial Results of Selecting Optimal Monochromatic Image for Beam-Hardening Artifacts and Image Noise Reduction , 2011, Journal of computer assisted tomography.

[5]  Kevin A Hallgren,et al.  Computing Inter-Rater Reliability for Observational Data: An Overview and Tutorial. , 2012, Tutorials in quantitative methods for psychology.

[6]  Bruno De Man,et al.  Dual-Energy Computed Tomography: Physical Principles, Approaches to Scanning, Usage, and Implementation: Part 2. , 2017, Neuroimaging clinics of North America.

[7]  D. Sahani,et al.  Virtual monochromatic reconstruction of dual-energy unenhanced head CT at 65-75 keV maximizes image quality compared with conventional polychromatic CT. , 2013, Radiology.

[8]  R. Dossi,et al.  Iodine Extravasation Quantification on Dual-Energy CT of the Brain Performed after Mechanical Thrombectomy for Acute Ischemic Stroke Can Predict Hemorrhagic Complications , 2018, American Journal of Neuroradiology.

[9]  James H Thrall,et al.  Comparison of image quality between conventional and low-dose nonenhanced head CT. , 2004, AJNR. American journal of neuroradiology.

[10]  E. Klotz,et al.  The role of dual energy CT in differentiating between brain haemorrhage and contrast medium after mechanical revascularisation in acute ischaemic stroke , 2014, European Radiology.

[11]  Toshihide Itoh,et al.  Dual energy computed tomography for the head , 2018, Japanese Journal of Radiology.

[12]  D. Maintz,et al.  Improvement of Image Quality in Unenhanced Dual-Layer CT of the Head Using Virtual Monoenergetic Images Compared With Polyenergetic Single-Energy CT , 2017, Investigative radiology.

[13]  N. Stence,et al.  Dual energy head CT to maintain image quality while reducing dose in pediatric patients. , 2019, Clinical imaging.

[14]  Jijo Paul,et al.  Image fusion in dual energy computed tomography for detection of various anatomic structures--effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality. , 2011, European journal of radiology.

[15]  Qualitative Comparison of Noncontrast Head Dual-Energy Computed Tomography Using Rapid Voltage Switching Technique and Conventional Computed Tomography , 2016, Journal of computer assisted tomography.

[16]  B. Choi,et al.  Image Fusion in Dual Energy Computed Tomography for Detection of Hypervascular Liver Hepatocellular Carcinoma: Phantom and Preliminary Studies , 2010, Investigative radiology.

[17]  Sachio Kuribayashi,et al.  Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT. , 2011, Radiology.

[18]  D. Cicchetti Guidelines, Criteria, and Rules of Thumb for Evaluating Normed and Standardized Assessment Instruments in Psychology. , 1994 .

[19]  B. Krauss,et al.  Advanced virtual monochromatic reconstruction of dual-energy unenhanced brain computed tomography in children: comparison of image quality against standard mono-energetic images and conventional polychromatic computed tomography , 2017, Pediatric Radiology.