A model for the linear stability of the interface between aqueous humor and vitreous substitutes after vitreoretinal surgery

We consider the motion of two immiscible viscous fluids induced by periodic oscillations of a flat solid surface along its plane. The interface between the two fluids is parallel to the solid wall; one fluid occupies the region between the wall and the interface and the other extends from the interface to infinity. We study numerically the linear stability of the interface with respect to two-dimensional perturbations using the normal mode analysis and assuming quasi-steady flow conditions. The analysis is motivated by the need of understanding the behavior of vitreous substitutes inserted in the vitreous chamber of the eye after vitrectomy. This is a common surgical procedure adopted to treat retinal detachments, whereby the vitreous humor is removed from the eye and replaced by fluids immiscible with water. Owing to their hydrophobic nature, vitreous substitutes coexist in the vitreous chamber with a certain amount of aqueous humor (the fluid produced in the anterior part of the eye) and, typically, a t...

[1]  H. Squire On the Stability for Three-Dimensional Disturbances of Viscous Fluid Flow between Parallel Walls , 1933 .

[2]  W. O. Criminale,et al.  The stability of time-dependent laminar flow: Parallel flows , 1965 .

[3]  Chia-Shun Yih,et al.  Instability of unsteady flows or configurations Part 1. Instability of a horizontal liquid layer on an oscillating plane , 1968, Journal of Fluid Mechanics.

[4]  Chin‐Hsiu Li Instability of Time‐Periodic Flows of Stratified Fluids , 1970 .

[5]  S. H. Davis,et al.  Linear stability theory of oscillatory Stokes layers , 1974, Journal of Fluid Mechanics.

[6]  J. Tiedeman,et al.  Effect of silicone oil viscosity on emulsification. , 1987, Archives of ophthalmology.

[7]  A. Kampik,et al.  EXPERIMENTAL EVALUATION OF IN VITRO STABILITY OF PURIFIED POLYDIMETHYLSILOXANES (SILICONE OIL) IN VISCOSITY RANGES FROM 1000 TO 5000 CENTISTOKES , 1992, Retina.

[8]  E. Bartov,et al.  Role of blood components in ocular silicone oil emulsification. Studies on an in vitro model. , 1996, Investigative ophthalmology & visual science.

[9]  A. Or Finite-wavelength instability in a horizontal liquid layer on an oscillating plane , 1997, Journal of Fluid Mechanics.

[10]  T. David,et al.  A model for the fluid motion of vitreous humour of the human eye during saccadic movement. , 1998, Physics in medicine and biology.

[11]  A. Reichenbach,et al.  Failure of potassium siphoning by Müller cells: a new hypothesis of perfluorocarbon liquid-induced retinopathy. , 2000, Investigative ophthalmology & visual science.

[12]  P. Schmid,et al.  Stability and Transition in Shear Flows. By P. J. SCHMID & D. S. HENNINGSON. Springer, 2001. 556 pp. ISBN 0-387-98985-4. £ 59.50 or $79.95 , 2000, Journal of Fluid Mechanics.

[13]  A. Bassom,et al.  The linear stability of flat Stokes layers , 2002, Journal of Fluid Mechanics.

[14]  P. Hall On the instability of Stokes layers at high Reynolds numbers , 2003, Journal of Fluid Mechanics.

[15]  R. Banerjee,et al.  Artificial vitreous replacements. , 2003, Bio-medical materials and engineering.

[16]  A. Kampik,et al.  Emulsification of silicone oils with specific physicochemical characteristics , 2004, Graefe's Archive for Clinical and Experimental Ophthalmology.

[17]  W. Schulenburg,et al.  An experimental study on the effect of encircling band procedure on silicone oil emulsification , 2004, British Journal of Ophthalmology.

[18]  J. Dresp,et al.  INTERACTION OF DIFFERENT OCULAR ENDOTAMPONADES AS A RISK FACTOR FOR SILICONE OIL EMULSIFICATION , 2004, Retina.

[19]  Rodolfo Repetto,et al.  An Analytical Model of the Dynamics of the Liquefied Vitreous Induced by Saccadic Eye Movements , 2006 .

[20]  R. Repetto,et al.  Eye rotation induced dynamics of a Newtonian fluid within the vitreous cavity: the effect of the chamber shape , 2007, Physics in medicine and biology.

[21]  A. Bassom,et al.  On the linear stability of Stokes layers , 2008, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[22]  M. Güler,et al.  The Role of Nystagmus in Silicone Oil Emulsification after Pars Plana Vitrectomy and Silicone Oil Injection for Complex Retinal Detachment , 2008, European journal of ophthalmology.

[23]  H. Heimann,et al.  Heavy tamponade 1: a review of indications, use, and complications , 2008, Eye.

[24]  P. Ichhpujani,et al.  Silicone oil induced glaucoma: A review , 2009, Graefe's Archive for Clinical and Experimental Ophthalmology.

[25]  Victor H. Barocas,et al.  Contribution of Saccadic Motion to Intravitreal Drug Transport: Theoretical Analysis , 2011, Pharmaceutical Research.

[26]  S. Kaushal,et al.  Vitreous substitutes: a comprehensive review. , 2011, Survey of ophthalmology.

[27]  C. Ng,et al.  Emulsification of silicone oil and eye movements. , 2011, Investigative ophthalmology & visual science.

[28]  R. Repetto,et al.  Oscillatory motion of a viscoelastic fluid within a spherical cavity , 2011, Journal of Fluid Mechanics.

[29]  P. Boesiger,et al.  Vitreous deformation during eye movement , 2012, NMR in biomedicine.

[30]  H. Cakmak,et al.  TIME COURSE OF SILICONE OIL EMULSIFICATION , 2012, Retina.

[31]  F. Kuhn,et al.  Rhegmatogenous Retinal Detachment: A Reappraisal of Its Pathophysiology and Treatment , 2013, Ophthalmic Research.