Cannula selection and cannulation techniques for nonpulsatile mechanical ventricular assistance.

The successful use of mechanical ventricular assistance is, in large part, dependent upon easy insertion of well designed inflow and outflow cannulas. This manuscript describes a family of cannulas specifically designed for use in a nonpulsatile ventricular assist device (VAD) circuit. Although a variety of commercially available cannulas can be employed in a nonpulsatile VAD circuit, the cannulas described in this manuscript possess a number of unique design features. The reinforced thin-walled design and end hole construction optimize fluid flow characteristics in both the inflow and outflow cannula. The extended length allows the cannulas to transverse the skin at a point far distant from the mediastinum, reducing the potential for ascending cannula site infection. The purpose of this manuscript is not to review all cannulas available for nonpulsatile VAD circuits, but rather to describe in detail a family of cannulas that are ideal VAD cannulas based on their design characteristics. In addition individual cardiac surgeons implant very few of these devices annually. Thus the advantages and disadvantages of common cannulation sites and a proven technique for cannula insertion will also be presented.

[1]  F. Spencer,et al.  A method of closed-chest cannulation of the left atrium for left atrial-femoral artery bypass. , 1975, The Journal of thoracic and cardiovascular surgery.

[2]  T. Okano,et al.  Suppression mechanisms for thrombus formation on heparin-immobilized segmented polyurethane-ureas. , 1988, ASAIO transactions.

[3]  W. Pae,et al.  Reduction of myocardial infarct size: comparison between left atrial and left ventricular bypass. , 1979, Circulation.

[4]  R. Bartlett,et al.  New method for describing the performance of cardiac surgery cannulas. , 1992, The Annals of thoracic surgery.

[5]  D. Swanson,et al.  Effect of cannulation site on the primary determinants of myocardial oxygen consumption during left heart bypass. , 1988, The Journal of surgical research.

[6]  L. Joyce,et al.  Experience with the Sarns centrifugal pump as a ventricular assist device. , 1990, ASAIO transactions.

[7]  J. Hayashi,et al.  Mechanical circulatory assist using heparin-coated tube and roller pump system. , 1992, The Annals of thoracic surgery.

[8]  W S Pierce,et al.  Segmented Polyurethane: A New Elastomer for Biomedical Applications , 1967, Science.

[9]  Å. Senning,et al.  Clinical use of a cannula for left heart bypass without thoracotomy: experimental protection against fibrillation by left heart bypass. , 1962, Annals of surgery.

[10]  J. Bavaria,et al.  Left ventricular mechanics of ejecting, postischemic hearts during left ventricular circulatory assistance. , 1991, The Journal of thoracic and cardiovascular surgery.

[11]  E. Savage,et al.  Left ventricular assistance without thoracotomy: mediastinal and transseptal approaches to the left heart. , 1992, The Annals of thoracic surgery.

[12]  P Litwak,et al.  In vivo evaluations of a new thromboresistant polyurethane for artificial heart blood pumps. , 1988, The Journal of thoracic and cardiovascular surgery.

[13]  B. Griffith,et al.  Infections and thromboembolism with implantable cardiovascular devices. , 1989, ASAIO transactions.

[14]  R. Frater,et al.  A comparison of flow gradients across disposable arterial perfusion cannulas. , 1985, The Annals of thoracic surgery.

[15]  W. Pierce,et al.  Hemodynamic and metabolic studies during two types of left ventricular bypass. , 1972, Surgical forum.