On the effect of resistive EEG electrodes and leads during 7 T MRI: simulation and temperature measurement studies.

The purpose of the study was to assess the effects of electrodes and leads on electromagnetic field and specific absorption rate (SAR) distributions during simultaneous electroencephalography (EEG) and 7-T MRI. Two different approaches were evaluated and compared to the case without electrodes: (a) the use of different EEG lead resistivity and (b) the use of a radiofrequency (RF) resistor on the lead near the EEG electrode. These configurations are commonly used in research and clinical settings. Electromagnetic field and SAR distributions generated by the transmit RF coil were evaluated using finite difference time domain simulations on an anatomically accurate head model. The spatiotemporal changes of temperature were estimated with the heat equation. Temperature changes during turbo spin echo sequences were also measured using a custom-made phantom: the conductive head mannequin anthropomorphic (CHEMA). The results of this study showed that the SAR and temperature distributions in CHEMA (a) increased when using low resistive leads, with respect to the no-electrode case; (b) were affected by the resistivity of the EEG leads, with carbon fiber leads performing better than standard copper leads; and (c) were not affected by the use of an RF resistor between the EEG electrode and the lead.

[1]  Frank G. Shellock Magnetic Resonance Procedures: Health Effects and Safety , 2000 .

[2]  Ali R. Rezai,et al.  Gelled versus nongelled phantom material for measurement of MRI-induced temperature increases with bioimplants , 2003 .

[3]  Bradley G. Goodyear,et al.  Simultaneous 3-T fMRI and high-density recording of human auditory evoked potentials , 2004, NeuroImage.

[4]  Tetsuya Matsuda,et al.  Influence of arousal level for functional magnetic resonance imaging (fMRI) study: Simultaneous recording of fMRI and electroencephalogram , 2002, Psychiatry and clinical neurosciences.

[5]  Rami K. Niazy,et al.  Simultaneous recording of laser-evoked brain potentials and continuous, high-field functional magnetic resonance imaging in humans , 2005, NeuroImage.

[6]  H. H. Pennes Analysis of tissue and arterial blood temperatures in the resting human forearm. 1948. , 1948, Journal of applied physiology.

[7]  Michael B. Smith,et al.  Calculations of B1 distribution, SNR, and SAR for a surface coil adjacent to an anatomically‐accurate human body model , 2001, Magnetic resonance in medicine.

[8]  F. Kruggel,et al.  Hemodynamic and Electroencephalographic Responses to Illusory Figures: Recording of the Evoked Potentials during Functional MRI , 2001, NeuroImage.

[9]  P. A. Mason,et al.  Empirical validation of SAR values predicted by FDTD modeling * † , 2002, Bioelectromagnetics.

[10]  Afraim Salek-Haddadi,et al.  Event-Related fMRI with Simultaneous and Continuous EEG: Description of the Method and Initial Case Report , 2001, NeuroImage.

[11]  Frank Bihari,et al.  MRI compatible EEG electrode system for routine use in the epilepsy monitoring unit and intensive care unit , 2004, Clinical Neurophysiology.

[12]  J. Belliveau,et al.  Metallic electrodes and leads in simultaneous EEG‐MRI: Specific absorption rate (SAR) simulation studies , 2004, Bioelectromagnetics.

[13]  F A Jolesz,et al.  Thermal dosimetry of a focused ultrasound beam in vivo by magnetic resonance imaging. , 1999, Medical physics.

[14]  W S Hinshaw,et al.  Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging. , 1983, Radiology.

[15]  J. Baudewig,et al.  Simultaneous EEG and functional MRI of epileptic activity: a case report , 2001, Clinical Neurophysiology.

[16]  K. Uğurbil,et al.  Phantom design method for high‐field MRI human systems , 2004, Magnetic resonance in medicine.

[17]  R. Gilchrist,et al.  Radiofrequency Electromagnetic Fields, Properties, Quantities and Units, Biophysical Interaction, and Measurements , 1984 .

[18]  C Gabriel,et al.  The dielectric properties of biological tissues: I. Literature survey. , 1996, Physics in medicine and biology.

[19]  T. Ibrahim,et al.  Analysis of B1 field profiles and SAR values for multi-strut transverse electromagnetic RF coils in high field MRI applications. , 2001, Physics in medicine and biology.

[20]  James C. Lin,et al.  Radio frequency electromagnetic exposure: tutorial review on experimental dosimetry. , 1996, Bioelectromagnetics.

[21]  P. Skudlarski,et al.  Correlations and dissociations between BOLD signal and P300 amplitude in an auditory oddball task: a parametric approach to combining fMRI and ERP. , 2002, Magnetic resonance imaging.

[22]  J Sijbers,et al.  Restoration of MR-induced artifacts in simultaneously recorded MR/EEG data. , 1999, Magnetic resonance imaging.

[23]  D. Regan Human brain electrophysiology: Evoked potentials and evoked magnetic fields in science and medicine , 1989 .

[24]  G. Bonmassar,et al.  Resistive tapered stripline (RTS) in electroencephalogram recordings during MRI , 2004, IEEE Transactions on Microwave Theory and Techniques.

[25]  S. J. Allen,et al.  Thermophysiological responses of human volunteers to whole body RF exposure at 220 MHz , 2005, Bioelectromagnetics.

[26]  R. Luebbers,et al.  The Finite Difference Time Domain Method for Electromagnetics , 1993 .

[27]  Mark S. Cohen,et al.  Acquiring simultaneous EEG and functional MRI , 2000, Clinical Neurophysiology.

[28]  J Gotman,et al.  Intrinsic epileptogenicity in polymicrogyric cortex suggested by EEG-fMRI BOLD responses , 2005, Neurology.

[29]  Emmanuel Perrin,et al.  RF‐induced temperature elevation along metallic wires in clinical magnetic resonance imaging: Influence of diameter and length , 2004, Magnetic resonance in medicine.

[30]  O. Gandhi,et al.  Finite-difference time-domain calculations of SAR in a realistic heterogeneous model of the head for plane-wave exposure from 600 MHz to 3 GHz. , 1991, Physics in medicine and biology.

[31]  R. Edelman,et al.  Magnetic resonance imaging (2) , 1993, The New England journal of medicine.

[32]  P. Achermann,et al.  Radio frequency electromagnetic field exposure in humans: Estimation of SAR distribution in the brain, effects on sleep and heart rate , 2003, Bioelectromagnetics.

[33]  Allen Taflove,et al.  Computational Electrodynamics the Finite-Difference Time-Domain Method , 1995 .

[34]  K. Uğurbil,et al.  Temperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHz , 2004, Journal of magnetic resonance imaging : JMRI.

[35]  Jean A. Tkach,et al.  Evaluation of specific absorption rate as a dosimeter of MRI‐related implant heating , 2004, Journal of magnetic resonance imaging : JMRI.

[36]  J. Armony,et al.  Auditory Processing across the Sleep-Wake Cycle Simultaneous EEG and fMRI Monitoring in Humans , 2000, Neuron.

[37]  Paul Horowitz,et al.  The Art of Electronics , 1980 .

[38]  A W Guy,et al.  Carbon-loaded Teflon electrodes for chronic EEG recordings in microwave research. , 1979, The Journal of microwave power.

[39]  Mark S. Mirotznik,et al.  Numerical evaluation of heating of the human head due to magnetic resonance imaging , 2004, IEEE Transactions on Biomedical Engineering.

[40]  F. Shellock,et al.  8.0‐Tesla human MR system: Temperature changes associated with radiofrequency‐induced heating of a head phantom , 2003, Journal of magnetic resonance imaging : JMRI.

[41]  Jianming Jin Electromagnetic Analysis and Design in Magnetic Resonance Imaging , 1998 .

[42]  Giorgio Bonmassar,et al.  Influence of EEG electrodes on the BOLD fMRI signal , 2001, Human brain mapping.

[43]  Jean Gotman,et al.  The BOLD Response to Interictal Epileptiform Discharges , 2002, NeuroImage.

[44]  L. Lemieux,et al.  Recording of EEG during fMRI experiments: Patient safety , 1997, Magnetic resonance in medicine.

[45]  J. McDougall,et al.  RF heating of implanted spinal fusion stimulator during magnetic resonance imaging , 1996, IEEE Transactions on Biomedical Engineering.

[46]  Herta Flor,et al.  Simultaneous electroencephalography and functional magnetic resonance imaging of primary and secondary somatosensory cortex in humans after electrical stimulation , 2002, Neuroscience Letters.