The use of shield wires for reducing induced voltages from lightning electromagnetic fields

Abstract The mechanisms from which lightning overvoltages can be produced on a power line depend on the system voltage. In medium voltage (MV) overhead distribution systems, lightning transients can be originated from either direct or indirect strokes. The main methods that can be adopted to improve the line lightning performance concern the increase of the critical impulse flashover voltage (CFO) of the line structures, the installation of surge arresters, and the use of one or more shield wires. This paper deals with the evaluation of the effectiveness of shield wires in reducing the magnitudes of the surges induced by nearby strokes on MV distribution lines. Such effectiveness depends on the combination of several parameters such as the relative position of the shield wire with respect to the phase conductors, the grounding interval, the ground resistance, the stroke current steepness, and the relative position of the stroke channel with respect to the grounding points. Realistic situations corresponding to typical configurations of a rural distribution line with either an overhead ground wire or a neutral conductor are considered. The analysis is carried out based on both computer simulations and test results obtained from scale model experiments, under controlled conditions.

[1]  Alexandre Piantini,et al.  The effectiveness of shield wires in reducing induced voltages from lightning electromagnetic fields , 2011, 2011 7th Asia-Pacific International Conference on Lightning.

[2]  Alberto De Conti,et al.  Voltages Induced in Single-Phase Overhead Lines by First and Subsequent Negative Lightning Strokes: Influence of the Periodically Grounded Neutral Conductor and the Ground Resistivity , 2011, IEEE Transactions on Electromagnetic Compatibility.

[3]  S. Rusck,et al.  Induced-lightning overvoltages on power transmission lines with special reference to the overvoltage protection of low voltage networks , 1958 .

[4]  F. Rachidi,et al.  Mitigation of lightning-induced overvoltages in medium Voltage distribution lines by means of periodical grounding of shielding wires and of surge arresters: modeling and experimental validation , 2004, IEEE Transactions on Power Delivery.

[5]  A. Piantini,et al.  Lightning-Induced Voltages on Overhead Lines—Application of the Extended Rusck Model , 2009, IEEE Transactions on Electromagnetic Compatibility.

[6]  M. Paolone,et al.  An Improved Procedure for the Assessment of Overhead Line Indirect Lightning Performance and Its Comparison with the IEEE Std. 1410 Method , 2007, IEEE Transactions on Power Delivery.

[7]  M. Uman,et al.  Magnetic field of lightning return stroke , 1969 .

[8]  Abderrahmane Haddad,et al.  Lightning Protection of Low Voltage Networks , 2013 .

[9]  M. Ianoz,et al.  Transient analysis of multiconductor lines above a lossy ground , 1999 .

[10]  M. Ianoz,et al.  Response of multiconductor power lines to nearby lightning return stroke electromagnetic fields , 1996 .

[11]  M. Ianoz,et al.  Influence of a lossy ground on lightning-induced voltages on overhead lines , 1996 .

[12]  Alexandre Piantini,et al.  Induced voltages on distribution lines due to lightning discharges on nearby metallic structures , 1998 .

[13]  Alexandre Piantini,et al.  The extended rusck model for calculating lightning induced voltages on overhead lines , 2003 .

[14]  A. Piantini,et al.  An improved model for lightning induced voltages calculations , 2004, 2004 IEEE/PES Transmision and Distribution Conference and Exposition: Latin America (IEEE Cat. No. 04EX956).

[15]  R. C. Dugan,et al.  Protecting distribution transformers from low-side current surges , 1990 .

[16]  Kunihiko Miyake,et al.  Advanced Observations of Lightning Induced Voltage on Power Distribution Lines (II) , 1986, IEEE Power Engineering Review.

[17]  S. Yokoyama Experimental analysis of earth wires for induced lightning surges , 1980 .

[18]  S. Yokoyama,et al.  Analogue simulation of lightning induced voltages and its application for analysis of overhead-ground-wire effects , 1985 .

[19]  Shigeru Yokoyama,et al.  Lightning protection of overhead power distribution lines , 2006 .

[20]  S. Yokoyama Calculation of Lightning-Induced Voltages on Overhead Multiconductor Systems , 1984, IEEE Power Engineering Review.

[21]  A. Piantini,et al.  A Scale Model for the Study of the LEMP Response of Complex Power Distribution Networks , 2007, IEEE Transactions on Power Delivery.

[22]  Kunihiko Miyake,et al.  Simultaneous Measurement of Lightning Induced Voltages with Associated Stroke Currents , 1983, IEEE Transactions on Power Apparatus and Systems.

[23]  P. Chowdhuri,et al.  Lightning-induced voltages on multiconductor overhead lines , 1990 .

[24]  R. C. Dugan,et al.  Low-voltage-side current-surge phenomena in single-phase distribution transformer systems , 1988 .

[25]  Carlo Alberto Nucci Lightning - Induced voltages on distribution systems: influence of ground resistivity and system topology , 2007 .