Calculating gait kinematics using MR-based kinematic models.

Rescaling generic models is the most frequently applied approach in generating biomechanical models for inverse kinematics. Nevertheless it is well known that this procedure introduces errors in calculated gait kinematics due to: (1) errors associated with palpation of anatomical landmarks, (2) inaccuracies in the definition of joint coordinate systems. Based on magnetic resonance (MR) images, more accurate, subject-specific kinematic models can be built that are significantly less sensitive to both error types. We studied the difference between the two modelling techniques by quantifying differences in calculated hip and knee joint kinematics during gait. In a clinically relevant patient group of 7 pediatric cerebral palsy (CP) subjects with increased femoral anteversion, gait kinematic were calculated using (1) rescaled generic kinematic models and (2) subject-specific MR-based models. In addition, both sets of kinematics were compared to those obtained using the standard clinical data processing workflow. Inverse kinematics, calculated using rescaled generic models or the standard clinical workflow, differed largely compared to kinematics calculated using subject-specific MR-based kinematic models. The kinematic differences were most pronounced in the sagittal and transverse planes (hip and knee flexion, hip rotation). This study shows that MR-based kinematic models improve the reliability of gait kinematics, compared to generic models based on normal subjects. This is the case especially in CP subjects where bony deformations may alter the relative configuration of joint coordinate systems. Whilst high cost impedes the implementation of this modeling technique, our results demonstrate that efforts should be made to improve the level of subject-specific detail in the joint axes determination.

[1]  Jacob Cohen Statistical Power Analysis for the Behavioral Sciences , 1969, The SAGE Encyclopedia of Research Design.

[2]  Aurelio Cappozzo,et al.  Enhanced anatomical calibration in human movement analysis. , 2007, Gait & posture.

[3]  Frank G Shellock,et al.  Functional Assessment of the Joints Using Kinematic Magnetic Resonance Imaging , 2003, Seminars in musculoskeletal radiology.

[4]  Stefano Zaffagnini,et al.  Evaluation of formal methods in hip joint center assessment: an in vitro analysis. , 2010, Clinical biomechanics.

[5]  A Cappello,et al.  Effects of hip joint centre mislocation on gait analysis results. , 2000, Journal of biomechanics.

[6]  A Leardini,et al.  Position and orientation in space of bones during movement: experimental artefacts. , 1996, Clinical biomechanics.

[7]  H. Rubash,et al.  Sensitivity of the knee joint kinematics calculation to selection of flexion axes. , 2004, Journal of biomechanics.

[8]  Hartmut Witte,et al.  ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion--part I: ankle, hip, and spine. International Society of Biomechanics. , 2002, Journal of biomechanics.

[9]  S. Delp,et al.  Cine phase-contrast magnetic resonance imaging as a tool for quantification of skeletal muscle motion. , 2003, Seminars in musculoskeletal radiology.

[10]  L. Schutte,et al.  An index for quantifying deviations from normal gait. , 2000, Gait & posture.

[11]  Scott L. Delp,et al.  A Model of the Lower Limb for Analysis of Human Movement , 2010, Annals of Biomedical Engineering.

[12]  Sheldon R Simon,et al.  Quantification of human motion: gait analysis-benefits and limitations to its application to clinical problems. , 2004, Journal of biomechanics.

[13]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 3. Soft tissue artifact assessment and compensation. , 2005, Gait & posture.

[14]  F.E. Zajac,et al.  An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures , 1990, IEEE Transactions on Biomedical Engineering.

[15]  F. Zajac,et al.  A planar model of the knee joint to characterize the knee extensor mechanism. , 1989, Journal of biomechanics.

[16]  Lorenzo Chiari,et al.  Human movement analysis using stereophotogrammetry. Part 4: assessment of anatomical landmark misplacement and its effects on joint kinematics. , 2005, Gait & posture.

[17]  S. Delp,et al.  Accuracy of muscle moment arms estimated from MRI-based musculoskeletal models of the lower extremity. , 2000, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[18]  S. Piazza,et al.  Measurement of the screw-home motion of the knee is sensitive to errors in axis alignment. , 2000, Journal of biomechanics.

[19]  P R Cavanagh,et al.  Accuracy of the functional method of hip joint center location: effects of limited motion and varied implementation. , 2001, Journal of biomechanics.

[20]  Paul J. Besl,et al.  A Method for Registration of 3-D Shapes , 1992, IEEE Trans. Pattern Anal. Mach. Intell..

[21]  Anthony G Schache,et al.  Defining the knee joint flexion-extension axis for purposes of quantitative gait analysis: an evaluation of methods. , 2006, Gait & posture.

[22]  Jon R. Davids,et al.  The Treatment of Gait Problems in Cerebral Palsy , 2005 .

[23]  J J O'Connor,et al.  Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints. , 1999, Journal of biomechanics.

[24]  U. Narayanan,et al.  The role of gait analysis in the orthopaedic management of ambulatory cerebral palsy , 2007, Current opinion in pediatrics.

[25]  R. B. Davis,et al.  A gait analysis data collection and reduction technique , 1991 .

[26]  A. Cappozzo,et al.  Pelvis and lower limb anatomical landmark calibration precision and its propagation to bone geometry and joint angles , 1999, Medical & Biological Engineering & Computing.

[27]  Nadia Magnenat-Thalmann,et al.  Bone motion analysis from dynamic MRI: acquisition and tracking. , 2005 .

[28]  Paul Suetens,et al.  Image Based Musculoskeletal Modeling Allows Personalized Biomechanical Analysis of Gait , 2006, ISBMS.

[29]  David G Lloyd,et al.  Repeatability of gait data using a functional hip joint centre and a mean helical knee axis. , 2003, Journal of biomechanics.

[30]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 2: instrumental errors. , 2004, Gait & posture.

[31]  Angelo Cappello,et al.  Multiple anatomical landmark calibration for optimal bone pose estimation , 1997 .

[32]  M P Kadaba,et al.  Measurement of lower extremity kinematics during level walking , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[33]  Kaat Desloovere,et al.  Effects of tendon vibration on the spatiotemporal characteristics of human locomotion , 2002, Experimental Brain Research.

[34]  Paul Suetens,et al.  Personalized MR-based musculoskeletal models compared to rescaled generic models in the presence of increased femoral anteversion: effect on hip moment arm lengths. , 2008, Gait & posture.

[35]  Bryan Buchholz,et al.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. , 2005, Journal of biomechanics.

[36]  A S Arnold,et al.  Do the hamstrings and adductors contribute to excessive internal rotation of the hip in persons with cerebral palsy? , 2000, Gait & posture.