Modeling pollutant penetration across building envelopes

As air infiltrates through unintentional openings in building envelopes, pollutants may interact with adjacent surfaces. Such interactions can alter human exposure to air pollutants of outdoor origin. We present modeling explorations of the proportion of particles and reactive gases (e.g., ozone) that penetrate building envelopes as air enters through cracks and wall cavities. Calculations were performed for idealized rectangular cracks, assuming regular geometry, smooth inner crack surface and steady airflow. Particles of 0.1–1.0 μm diameter are predicted to have the highest penetration efficiency, nearly unity for crack heights of 0.25 mm or larger, assuming a pressure difference of 4 Pa or greater and a flow path length of 3 cm or less. Supermicron and ultrafine particles are significantly removed by means of gravitational settling and Brownian diffusion, respectively. In addition to crack geometry, ozone penetration depends on its reactivity with crack surfaces, as parameterized by the reaction probability. For reaction probabilities less than ∼10−5, penetration is complete for cracks heights greater than ∼1 mm. However, penetration through mm scale cracks is small if the reaction probability is ∼10−4 or greater. For wall cavities, fiberglass insulation is an efficient particle filter, but particles would penetrate efficiently through uninsulated wall cavities or through insulated cavities with significant airflow bypass. The ozone reaction probability on fiberglass fibers was measured to be 10−7 for fibers previously exposed to high ozone levels and 6×10−6 for unexposed fibers. Over this range, ozone penetration through fiberglass insulation would vary from >90% to ∼10–40%. Thus, under many conditions penetration is high; however, there are realistic circumstances in which building envelopes can provide substantial pollutant removal. Not enough is yet known about the detailed nature of pollutant penetration leakage paths to reliably predict infiltration into real buildings.

[1]  R. A. Cox,et al.  Effect of relative humidity on the disappearance of ozone and sulphur dioxide in contained systems , 1972 .

[2]  W. Nazaroff,et al.  The Rate of Ozone Uptake on Carpets: Experimental Studies , 2000 .

[3]  Alvin C.K. Lai,et al.  Modeling Indoor Particle Deposition from Turbulent Flow onto Smooth Surfaces , 2000 .

[4]  C. P. Yu,et al.  Particle Deposition from Duct Flows by Combined Mechanisms , 1993 .

[5]  J. W. Thomas,et al.  THEORY OF A DIFFUSION BATTERY , 1952 .

[6]  William W. Nazaroff,et al.  Removal of reactive gases at indoor surfaces: Combining mass transport and surface kinetics , 1993 .

[7]  R. C. Sonderegger,et al.  Component leakage areas in residential buildings , 1983 .

[8]  P. Koutrakis,et al.  Modeling ozone deposition onto indoor residential surfaces. , 1994, Environmental science & technology.

[9]  B. Weiss,et al.  Association of particulate air pollution and acute mortality: involvement of ultrafine particles? , 1995, Inhalation toxicology.

[10]  P. H. Baker,et al.  Air flow through cracks , 1987 .

[11]  L. E. Sparks,et al.  Penetration of Ambient Fine Particles into the Indoor Environment , 2001 .

[12]  Jess W. Thomas The diffusion battery method for aerosol particle size determination , 1955 .

[13]  William W Nazaroff,et al.  Indoor Air Quality Impacts of Ventilation Ducts: Ozone Removal and Emissions of Volatile Organic Compounds. , 1998, Journal of the Air & Waste Management Association.

[14]  E. Karlsson,et al.  Influence of desorption on the indoor concentration of toxic gases , 1996 .

[15]  E. Karlsson,et al.  Indoor deposition reducing the effect of toxic gas clouds in ordinary buildings , 1994 .

[16]  R. H. Sabersky,et al.  Concentrations, decay rates, and removal of ozone and their relation to establishing clean indoor air , 1973 .

[17]  J.David Miller,et al.  Fungi as contaminants in indoor air , 1992 .

[18]  N. L. Nagda,et al.  Modeling of Indoor Air Quality and Exposure , 1993 .

[19]  C. N. Davies,et al.  The Mechanics of Aerosols , 1964 .

[20]  Ian Colbeck,et al.  Resistance of various building materials to ozone deposition , 1990 .

[21]  Frank X. Mueller,et al.  Decomposition rates of ozone in living areas , 1973 .

[22]  Refrigerating ASHRAE handbook : 1985 Fundamentals , 1985 .

[23]  J. Xue,et al.  Personal exposure to airborne particles and metals: results from the Particle TEAM study in Riverside, California. , 1996, Journal of exposure analysis and environmental epidemiology.

[24]  Tracy L. Thatcher,et al.  Deposition, resuspension, and penetration of particles within a residence , 1995 .

[25]  William W. Nazaroff,et al.  Critique of the Use of Deposition Velocity in Modeling Indoor Air Quality , 1993 .