Design and application of an assessment protocol for electromagnetic tracking systems.

This paper defines a simple protocol for competitive and quantified evaluation of electromagnetic tracking systems such as the NDI Aurora (A) and Ascension microBIRD with dipole transmitter (B). It establishes new methods and a new phantom design which assesses the reproducibility and allows comparability with different tracking systems in a consistent environment. A machined base plate was designed and manufactured in which a 50 mm grid of holes was precisely drilled for position measurements. In the center a circle of 32 equispaced holes enables the accurate measurement of rotation. The sensors can be clamped in a small mount which fits into pairs of grid holes on the base plate. Relative positional/orientational errors are found by subtracting the known distances/rotations between the machined locations from the differences of the mean observed positions/rotation. To measure the influence of metallic objects we inserted rods made of steel (SST 303, SST 416), aluminum, and bronze into the sensitive volume between sensor and emitter. We calculated the fiducial registration error and fiducial location error with a standard stylus calibration for both tracking systems and assessed two different methods of stylus calibration. The positional jitter amounted to 0.14 mm(A) and 0.08 mm(B). A relative positional error of 0.96mm±0.68mm, range -0.06 mm; 2.23 mm(A) and 1.14mm±0.78mm, range -3.72 mm; 1.57 mm(B) for a given distance of 50 mm was found. The relative rotation error was found to be 0.51° (A)/0.04° (B). The most relevant distortion caused by metallic objects results from SST 416. The maximum error 4.2mm(A)∕⩾100mm(B) occurs when the rod is close to the sensor(20 mm). While (B) is more sensitive with respect to metallic objects, (A) is less accurate concerning orientation measurements. (B) showed a systematic error when distances are calculated.

[1]  F. Raab,et al.  Magnetic Position and Orientation Tracking System , 1979, IEEE Transactions on Aerospace and Electronic Systems.

[2]  Bernard D. Adelstein,et al.  A testbed for characterizing dynamic response of virtual environment spatial sensors , 1992, UIST '92.

[3]  G Bashein,et al.  3D ultrasonic image feature localization based on magnetic scanhead tracking: in vitro calibration and validation. , 1994, Ultrasound in medicine & biology.

[4]  Jay B. West,et al.  Predicting error in rigid-body point-based registration , 1998, IEEE Transactions on Medical Imaging.

[5]  Wolfgang Birkfellner,et al.  Calibration of tracking systems in a surgical environment , 1998, IEEE Transactions on Medical Imaging.

[6]  K Matre,et al.  In vitro evaluation of three-dimensional ultrasonography based on magnetic scanhead tracking. , 1998, Ultrasound in medicine & biology.

[7]  H Bergmann,et al.  Systematic distortions in magnetic position digitizers. , 1998, Medical physics.

[8]  K. Paulsen,et al.  Error analysis for a free-hand three-dimensional ultrasound system for neuronavigation , 1999 .

[9]  A R Javer,et al.  Stereotactic Computer-Assisted Navigational Sinus Surgery: Accuracy of an Electromagnetic Tracking System with the Tissue Debrider and when Utilizing Different Headsets for the Same Patient , 2000, American journal of rhinology.

[10]  K P Wang,et al.  Three-dimensional CT-guided bronchoscopy with a real-time electromagnetic position sensor: a comparison of two image registration methods. , 2000, Chest.

[11]  M. Schalij,et al.  Three‐Dimensional Catheter Positioning During Radiofrequency Ablation in Patients: First Application of a Real‐Time Position Management System , 2000, Journal of cardiovascular electrophysiology.

[12]  E P Wilkinson,et al.  Comparative tracking error analysis of five different optical tracking systems. , 2000, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[13]  R. Metson,et al.  Physician Experience With an Optical Image Guidance System for Sinus Surgery , 2000, The Laryngoscope.

[14]  Wolfgang Birkfellner,et al.  Evaluation of a miniature electromagnetic position tracker. , 2002, Medical physics.

[15]  Wolfgang Birkfellner,et al.  Navigation system for flexible endoscopes , 2003, SPIE Medical Imaging.

[16]  Andrew D. Wiles,et al.  Accuracy assessment protocols for elektromagnetic tracking systems , 2003, CARS.

[17]  Makoto Hashizume,et al.  A Rapid Method for Magnetic Tracker Calibration Using a Magneto-Optic Hybrid Tracker , 2003, MICCAI.

[18]  Robert L. Galloway,et al.  A technique for validating image-guided gene therapy , 2003, SPIE Medical Imaging.

[19]  Andrew D. Wiles,et al.  Accuracy assessment and interpretation for optical tracking systems , 2004, Medical Imaging: Image-Guided Procedures.