Rapid detection of heavy metal-induced toxicity in water using a fed-batch sulfur-oxidizing bacteria (SOB) bioreactor.

A fed-batch bioreactor based on sulfur-oxidizing bacteria (SOB) was tested for rapid detection of heavy metal-induced toxicity in water. For this evaluation, SOB were exposed to water contaminated by selenium, mercury, hexavalent chromium, arsenic, cyanide, cadmium, and lead for 2 h and their inhibition rates were analyzed based on changes in electrical conductivity (EC). The results demonstrate that SOB were highly inhibited by selenium, mercury, hexavalent chromium, and arsenic but not by cyanide, cadmium, and lead. The 2 h half maximum effective concentrations (EC50) of SOB for selenium, mercury, hexavalent chromium, and arsenic were estimated to be 0.33, 0.89, 1.18, and 0.24 mg/L, respectively, which are comparable or lower than earlier reports in the literature. However, the EC50 or EC20 values of SOB for cyanide, cadmium, and lead were notably higher compared to findings from previous toxicity tests that employed other microorganisms. The findings from the current study suggest that the fed-batch SOB bioreactor is suitable for rapid detection of toxicity induced by selenium, mercury, hexavalent chromium, and arsenic in water.

[1]  Sangeun Oh,et al.  Improved detection of toxic chemicals by Photobacterium phosphoreum using modified Boss medium. , 2010, Journal of photochemistry and photobiology. B, Biology.

[2]  P. C. Nagajyoti,et al.  Heavy metals, occurrence and toxicity for plants: a review , 2010 .

[3]  Jianfu Zhao,et al.  p-Benzoquinone-mediated amperometric biosensor developed with Psychrobacter sp. for toxicity testing of heavy metals. , 2013, Biosensors & bioelectronics.

[4]  I. Tothill,et al.  Developments in bioassay methods for toxicity testing in water treatment , 1996 .

[5]  Damià Barceló,et al.  Sensors and biosensors in support of EU Directives , 2009 .

[6]  P. Tchounwou,et al.  Heavy metal toxicity and the environment. , 2012, Experientia supplementum.

[7]  Tsuguyoshi Suzuki,et al.  Toxicology of metals , 1996 .

[8]  C. Hsieh,et al.  Toxicity of the 13 priority pollutant metals to Vibrio fisheri in the Microtox chronic toxicity test. , 2004, The Science of the total environment.

[9]  Development of an Online Sulfur-Oxidizing Bacteria Biosensor for the Monitoring of Water Toxicity , 2014, Applied Biochemistry and Biotechnology.

[10]  P. A. Johnston,et al.  Acute toxicity of inorganic selenium to Daphnia magna (Straus) and the effect of sub-acute exposure upon growth and reproduction , 1987 .

[11]  Y. Tchan,et al.  A comparison of microbial bioassays for the detection of aquatic toxicants , 1983 .

[12]  C. Blaise,et al.  A semistatic microplate‐based phytotoxicity test , 1995 .

[13]  M. Gu,et al.  Evaluation of a high throughput toxicity biosensor and comparison with a Daphnia magna bioassay. , 2003, Biosensors & bioelectronics.

[14]  D. I. Mount,et al.  A seven‐day life cycle cladoceran toxicity test , 1984 .

[15]  Toxicity assessment of selected heavy metals in water using a seven-chambered sulfur-oxidizing bacterial (SOB) bioassay reactor , 2018 .

[16]  Beom-Soo Shin,et al.  Semi-continuous detection of toxic hexavalent chromium using a sulfur-oxidizing bacteria biosensor. , 2012, Journal of environmental management.

[17]  K. Ahmadi Angali,et al.  Acute toxicity test using cyanide on Daphnia magna by flow-through system , 2013, Journal of Water Chemistry and Technology.

[18]  F. Malcata,et al.  Toxicity of cadmium and zinc on two microalgae, Scenedesmus obliquus and Desmodesmus pleiomorphus, from Northern Portugal , 2011, Journal of Applied Phycology.

[19]  Marco Mascini,et al.  A comparison study between a disposable electrochemical DNA biosensor and a Vibrio fischeri-based luminescent sensor for the detection of toxicants in water samples. , 2006, Talanta.

[20]  A. Hartwig,et al.  Carcinogenic metal compounds: recent insight into molecular and cellular mechanisms , 2008, Archives of Toxicology.

[21]  J. Hughes,et al.  Microbial fuel cell biosensor for in situ assessment of microbial activity. , 2008, Biosensors & bioelectronics.

[22]  D. Häder,et al.  Rapid ecotoxicological bioassay of nickel and cadmium using motility and photosynthetic parameters of Euglena gracilis , 2010 .

[23]  Sang-Eun Oh,et al.  A novel biosensor for detecting toxicity in water using sulfur-oxidizing bacteria , 2009 .

[24]  Annemarie van Wezel,et al.  New methods to monitor emerging chemicals in the drinking water production chain. , 2010, Journal of environmental monitoring : JEM.

[25]  J. Fergusson The Heavy Elements: Chemistry, Environmental Impact and Health Effects , 1990 .

[26]  I. Kong Comparative Studies on the Acute Toxicities of Whole Solids and Solids Aqueous Extracts Based on the Inhibition of Bacterial Bioluminescence Production , 2011 .

[27]  C. Guéguen,et al.  Water toxicity and metal contamination assessment of a polluted river: the Upper Vistula River (Poland) , 2004 .

[28]  Blessy B. Mathew,et al.  Toxicity, mechanism and health effects of some heavy metals , 2014, Interdisciplinary toxicology.

[29]  R. Tauler,et al.  Toxicity assays applied to wastewater treatment. , 2005, Talanta.

[30]  A. Kabata-Pendias Trace elements in soils and plants , 1984 .

[31]  Sang-Eun Oh,et al.  Comparison of chromium III and VI toxicities in water using sulfur-oxidizing bacterial bioassays. , 2016, Chemosphere.

[32]  Jieun Park,et al.  A novel continuous toxicity test system using a luminously modified freshwater bacterium. , 2004, Biosensors & bioelectronics.

[33]  M. Madigan,et al.  Brock Biology of Microorganisms , 1996 .

[34]  Ashish Mehta,et al.  Heavy metal induced oxidative stress & its possible reversal by chelation therapy. , 2008, The Indian journal of medical research.

[35]  Sedky H. A. Hassan,et al.  Detection of Cr6+ by the sulfur oxidizing bacteria biosensor: effect of different physical factors. , 2012, Environmental science & technology.

[36]  J. Magnin,et al.  Bacterial sensors based on Acidithiobacillus ferrooxidans Part I. Fe2+ and S2O32- determination. , 2006, Biosensors & bioelectronics.

[37]  G. Shi,et al.  Toxicity Assessment of Cyanide and Tetramethylene Disulfotetramine (Tetramine) Using Luminescent Bacteria Vibrio‐qinghaiensis and PbO2 Electrochemical Sensor , 2007 .

[38]  D. Rawson,et al.  Whole cell biosensors--electrochemical and optical approaches to ecotoxicity testing. , 2001, Toxicology in vitro : an international journal published in association with BIBRA.

[39]  Richard John,et al.  A sensitive, rapid ferricyanide-mediated toxicity bioassay developed using Escherichia coli. , 2010, Talanta.

[40]  D. Barceló,et al.  Toxicity testing of wastewater and sewage sludge by biosensors, bioassays and chemical analysis , 2003 .

[41]  Shimshon Belkin,et al.  Are luminescent bacteria suitable for online detection and monitoring of toxic compounds in drinking water and its sources? , 2010, Analytical and bioanalytical chemistry.

[42]  M. Wenzel,et al.  Effects of Cadmium, Copper and Zinc on Growth of Four Isolated Algae from a Highly Polluted Argentina River , 2014, Bulletin of Environmental Contamination and Toxicology.

[43]  Jae-E. Yang,et al.  Detecting oxidized contaminants in water using sulfur-oxidizing bacteria. , 2011, Environmental science & technology.

[44]  W. Moselhy,et al.  Toxicity of Some Pesticides, Heavy Metals and Their Mixtures to Vibrio fischeri Bacteria and Daphnia magna: Comparative Study , 2015 .

[45]  Y. Tada,et al.  A simple and easy method for the monitoring of environmental pollutants using oligotrophic bacteria , 2001, Letters in applied microbiology.

[46]  D. Sponza Incorporation of Toxicity Tests into the Turkish Industrial Discharge Monitoring Systems , 2002, Archives of environmental contamination and toxicology.

[47]  J. Etxebarria,et al.  A comparison of five rapid direct toxicity assessment methods to determine toxicity of pollutants to activated sludge. , 2002, Chemosphere.

[48]  Xianglin Shi,et al.  Molecular mechanisms of metal toxicity and carcinogenesis , 2001, Molecular and Cellular Biochemistry.