An Evaluation of Analytical Methods, Air Sampling Techniques, and Airborne Occupational Exposure of Metalworking Fluids

This article summarizes an assessment of air sampling and analytical methods for both oil and water-based metalworking fluids (MWFs). Three hundred and seventy-four long-term area and personal airborne samples were collected at four plants using total (closed-face) aerosol samplers and thoracic samplers. A direct-reading device (DustTrak) was also used. The processes sampled include steel tube making, automotive component manufacturing, and small part manufacturing in a machine shop. The American Society for Testing and Materials (ASTM) Method PS42-97 of analysis was evaluated in the laboratory. This evaluation included sample recovery, determination of detection limits, and stability of samples during storage. Results of the laboratory validation showed (a) the sample recovery to be about 87%, (b) the detection limit to be 35 μg, and (c) sample stability during storage at room temperature to decline rapidly within a few days. To minimize sample loss, the samples should be stored in a freezer and analyzed within a week. The ASTM method should be the preferred method for assessing metalworking fluids (MWFs). The ratio of thoracic aerosol to total aerosol ranged from 0.6 to 0.7. A similar relationship was found between the thoracic extractable aerosol and total extractable aerosol. The DustTrak, with 10-μm sampling head, was useful in pinpointing the areas of potential exposure. MWF exposure at the four plants ranged from 0.04 to 3.84 mg/m 3 with the geometric mean ranging between 0.22 to 0.59 mg/m 3 . Based on this data and the assumption of log normality, MWF exposures are expected to exceed the National Institute for Occupational Safety and Health recommended exposure limit of 0.5 mg/m 3 as total mass and 0.4 mg/m 3 as thoracic mass about 38% of the time. In addition to controlling airborne MWF exposure, full protection of workers would require the institution of programs for fluid management and dermal exposure prevention.

[1]  L. C. Kenny,et al.  Characterization and modelling of a family of cyclone aerosol preseparators , 1995 .

[2]  B. Crook,et al.  Occupational exposure to metalworking fluid mist and sump fluid contaminants. , 2003, The Annals of occupational hygiene.

[3]  Martin A Stear Controlling health risks from workplace exposure to metalworking fluids in the United Kingdom engineering industry. , 2003, Applied occupational and environmental hygiene.

[4]  Jan H Urbanus,et al.  European hazard classification advice for crude oil-derived lubricant base oils compared with the proposed mineral oil mist TLV. , 2003, Applied occupational and environmental hygiene.

[5]  S. Semple,et al.  Dermal exposure to chemicals in the workplace: just how important is skin absorption? , 2004, Occupational and Environmental Medicine.

[6]  M. Boeniger The significance of skin exposure. , 2003, The Annals of occupational hygiene.

[7]  Robert E McCleery,et al.  Evaluation of the NIOSH MWF Total Particulate Matter: Thoracic Particulate Matter Conversion Factor in a Machining Environment , 2005, Journal of occupational and environmental hygiene.

[8]  P. Klinger,et al.  Data supporting a provisional American Society for Testing and materials (ASTM) method for metalworking fluids, Part 2 : Preliminary report of evaluation of a ternary solvent blend in a provisional ASTM method for metalworking fluids (P-42-97) , 1999 .

[9]  P. Hewett,et al.  Exact expressions for the bias and variance of estimators of the mean of a lognormal distribution. , 1992, American Industrial Hygiene Association journal.

[10]  A. Bracker,et al.  An outbreak of hypersensitivity pneumonitis at a metalworking plant: a longitudinal assessment of intervention effectiveness. , 2003, Applied occupational and environmental hygiene.

[11]  R. Fenske,et al.  Dermal exposure: a decade of real progress. , 2000, The Annals of occupational hygiene.

[12]  Martin Stear Metalworking fluids--clearing away the mist? , 2005, The Annals of occupational hygiene.

[13]  E. Eisen,et al.  Exposure-response models based on extended follow-up of a cohort mortality study in the automobile industry. , 2001, Scandinavian journal of work, environment & health.

[14]  D K Verma,et al.  Hydrocarbon exposures at petroleum bulk terminals and agencies. , 1992, American Industrial Hygiene Association journal.

[15]  D. Kriebel,et al.  Exposure assessment for a field investigation of the acute respiratory effects of metalworking fluids. I. Summary of findings. , 1996, American Industrial Hygiene Association journal.

[16]  H Kromhout,et al.  Dermal exposure assessment. , 2000, The Annals of occupational hygiene.

[17]  Thomas J. Smith,et al.  Summary of the findings from the exposure assessments for metalworking fluid mortality and morbidity studies. , 2003, Applied occupational and environmental hygiene.

[18]  J. Oudyk,et al.  Investigating respiratory responses to metalworking fluid exposure. , 2003, Applied occupational and environmental hygiene.

[19]  American Conference Of Governmental Industrial Hygienists 1998 Ventilation A O , 2019 .

[20]  Susan R. Woskie,et al.  Factors Affecting Worker Exposures to Metal-Working Fluids During Automotive Component Manufacturing , 1994 .

[21]  J H Vincent,et al.  Investigation into the impact of introducing workplace aerosol standards based on the inhalable fraction. , 1996, The Analyst.

[22]  Peter S. Thorne,et al.  Environmental Assessment of Aerosols, Bioaerosols, and Airborne Endotoxins in a Machining Plant , 1996 .

[23]  R. Glaser,et al.  An evaluation of ASTM method P-42-97 for sampling and analysis of metalworking fluids. , 2003, Applied Occupational and Environmental Hygiene.

[24]  K. Teschke,et al.  Change in airway responsiveness among apprentices exposed to metalworking fluids. , 1999, American journal of respiratory and critical care medicine.

[25]  James B. D'Arcy,et al.  Size Characteristics of Machining Fluid Aerosols in an Industrial Metalworking Environment , 1990 .

[26]  A Franzblau,et al.  Acute respiratory effects on workers exposed to metalworking fluid aerosols in an automotive transmission plant. , 1997, American journal of industrial medicine.

[27]  R. Glaser,et al.  Data Supporting a Provisional ASTM Method for Metalworking Fluids Part 3. Evaluation of an ASTM Method for Metalworking Fluids in a Survey of Metalworking Facilities , 2002 .

[28]  K. A. Busch,et al.  Occupational exposure sampling strategy manual , 1977 .

[29]  J. Vincent,et al.  Exposures to inhalable and "total" oil mist aerosol by metal machining shop workers. , 1996, American Industrial Hygiene Association journal.

[30]  Stephen L Gauthier Metalworking fluids: oil mist and beyond. , 2003, Applied occupational and environmental hygiene.

[31]  R. Glaser Data Supporting a Provisional American Society for Testing and Materials (ASTM) Method for Metalworking Fluids, Part I: A Solvent Blend with Wide-Ranging Ability to Dissolve Metalworking Fluids , 1999 .

[32]  David Kriebel,et al.  Occupational exposure to metalworking fluids and risk of breast cancer among female autoworkers. , 2005, American journal of industrial medicine.

[33]  E A Eisen,et al.  Size-selective pulmonary dose indices for metal-working fluid aerosols in machining and grinding operations in the automobile manufacturing industry. , 1994, American Industrial Hygiene Association journal.

[34]  D. Christiani,et al.  A field investigation of the acute respiratory effects of metal working fluids. I. Effects of aerosol exposures. , 1997, American journal of industrial medicine.

[35]  A Franzblau,et al.  Characterization of metalworking fluid exposure indices for a study of acute respiratory effects. , 2000, Applied occupational and environmental hygiene.

[36]  D. Kriebel,et al.  Respiratory health of automobile workers and exposures to metal-working fluid aerosols: lung spirometry. , 2001, American journal of industrial medicine.

[37]  An evaluation of short-term exposures to metalworking fluids in small machine shops. , 2001, AIHAJ : a journal for the science of occupational and environmental health and safety.

[38]  D M O'Brien,et al.  Metalworking fluid exposures in small machine shops: an overview. , 2001, AIHAJ : a journal for the science of occupational and environmental health and safety.