IMOTEPAD: A mixed-signal 64-channel front-end ASIC for small-animal PET imaging

Abstract This paper presents the design and characteristics of a mixed-signal 64-channel front-end readout ASIC called IMOTEPAD dedicated to multi-channel plate (MCP) photodetector coupled to LYSO scintillating crystals for small-animal PET imaging. In our configuration, the crystals are oriented in the axial direction readout on both sides by individual photodetector channels allowing the spatial resolution and the detection efficiency to be independent of each other. As a result, both energy signals and timing triggers from the photodetectors are required to be read out by the front-end ASIC. This dedicated ASIC IMOTEPAD comprises two parts: the analog part IMOTEPA and the digital part IMOTEPD. The IMOTEPA is dedicated to energy measurement. And the timing information is digitized by the IMOTEPD in which the key principal element is a time-to-digital converter (TDC) based on a delay-locked loop (DLL) with 32 delay cells. The chip is designed and fabricated in 0.35 μm CMOS process. The measurements show that for the analog part IMOTEPA, the energy gain is 13.1 mV/pC while the peak time of a CR-RC pulse shaper is 280 ns. The SNR is 39 dB and the RMS noise is 300 μV. The nonlinearity is less than 3%. The crosstalk is less than 0.2%. For the IMOTEPD, the bin size of the TDC is 625 ps with a reference clock of 50 MHz. The RMS jitter of the DLL is less than 42 ps. The DNL of the TDC is equal to about 0.17 LSB and the INL is equal to 0.31 LSB. The power dissipation of each channel is less than 16.8 mW. The design of the ASIC, especially for TDC and the measurement results of the IMOTEPAD will be presented and discussed in this paper.

[1]  Claude Colledani,et al.  A front-end readout mixed chip for high-efficiency small animal PET imaging , 2007 .

[3]  Hideo Murayama,et al.  A waveform sampling front-end ASIC for readout of GSO/APD with DOI information , 2007 .

[4]  A. Studen,et al.  Very High Resolution Small Animal PET in Strong Magnetic Fields , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[5]  J. M. Rochelle,et al.  Performance characteristics of a new generation of processing circuits for PET applications , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[6]  Sang-June Park,et al.  Design of a very high-resolution small animal PET scanner using a silicon scatter detector insert , 2007, Physics in medicine and biology.

[7]  M. Bandstra,et al.  Measurements of Fukushima fallout by the Berkeley Radiological Air and Water Monitoring project , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[8]  Gary D Hutchins,et al.  Small animal PET imaging. , 2004, ILAR journal.

[9]  S. Cherry,et al.  MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging. , 2003, Physics in medicine and biology.

[10]  I. Peric,et al.  Multi-Channel Readout ASIC for ToF-PET , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[11]  J. Benlloch,et al.  PESIC: An Integrated Front-End for PET Applications , 2007, IEEE Transactions on Nuclear Science.

[12]  J. M. Rochelle,et al.  A custom mixed signal CMOS integrated circuit for high performance PET tomograph front-end applications , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[13]  D. Brasse,et al.  Design of a High Performances Small Animal PET System With Axial Oriented Crystals and DOI Capability , 2009, IEEE Transactions on Nuclear Science.

[14]  K.S. Shah,et al.  An application-specific integrated circuit for positron emission tomography , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[15]  Claude Colledani,et al.  A Full-Custom Mixed-Signal CMOS Front-End Readout Chip for High Efficiency Small Animal PET Imaging , 2007, 2007 14th IEEE International Conference on Electronics, Circuits and Systems.

[16]  Shen-Iuan Liu,et al.  A wide-range delay-locked loop with a fixed latency of one clock cycle , 2002, IEEE J. Solid State Circuits.

[17]  C. de La Taille,et al.  MAROC: Multi-Anode ReadOut Chip for MaPMTs , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[18]  D Brasse,et al.  Design of a Multi-Channel Front-End Readout ASIC With Low Noise and Large Dynamic Input Range for APD-Based PET Imaging , 2010, IEEE Transactions on Nuclear Science.

[19]  Sibylle Ziegler,et al.  An analog signal processing ASIC for a small animal LSO–APD PET tomograph , 2006 .

[20]  M. Schmand,et al.  Design of a small animal PET imaging system with 1 microliter volume resolution , 2004, IEEE Transactions on Nuclear Science.

[21]  William J. Dally,et al.  Jitter transfer characteristics of delay-locked loops - theories and design techniques , 2003, IEEE J. Solid State Circuits.

[22]  Hirokazu Ikeda,et al.  Development of a low-noise analog front-end ASIC for APD-PET detectors , 2007 .

[23]  I. Peric,et al.  Fast Self Triggered Multi Channel Readout ASIC for Time- and Energy Measurement , 2009, IEEE Transactions on Nuclear Science.