A Modified Direct Power Control Strategy Allowing the Connection of Three-Phase Inverters to the Grid Through $LCL$ Filters

This paper proposes a novel approach to adapt a conventional direct power control (DPC) for high-power applications, where a third-order LCL filter is frequently required. The LCL filter can cause a strong resonance and requires additional effort for system control. The application of a DPC for the control of a three-phase voltage source inverter that is connected to the grid through an filter has not yet been considered. The addition of an active damping strategy, together with a harmonic rejection control loop, to the conventional DPC is proposed and analyzed in this paper. The steady-state, as well as the dynamic performance of the proposed system, is verified with simulation results and experimental measurements.

[1]  Pekik Argo Dahono A control method to damp oscillation in the input LC filter , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[2]  S. B. Dewan,et al.  Analysis of a PWM AC to DC voltage source converter under the predicted current control with a fixed switching frequency , 1991 .

[3]  S. Ponnaluri,et al.  Overriding individual harmonic current control with fast dynamics for active filtering , 2001, 2001 IEEE 32nd Annual Power Electronics Specialists Conference (IEEE Cat. No.01CH37230).

[4]  Toshihiko Noguchi,et al.  Direct power control of PWM converter without power source voltage sensors , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[5]  V. Blasko,et al.  A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter , 1997 .

[6]  M.P. Kazmierkowski,et al.  New direct power control of three-phase PWM boost rectifiers under distorted and imbalanced line voltage conditions , 2003, 2003 IEEE International Symposium on Industrial Electronics ( Cat. No.03TH8692).

[7]  Donald Grahame Holmes,et al.  Grid current regulation of a three-phase voltage source inverter with an LCL input filter , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[8]  Nik Rumzi Nik Idris,et al.  An improved stator flux estimation in steady state operation for direct torque control of induction machines , 2000 .

[9]  Mariusz Malinowski,et al.  Virtual flux based direct power control of three-phase PWM rectifiers , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).