Performance of Suspended Nonstructural Components and Their Anchorage during Shake Table Tests

Nonstructural components and systems are typically connected to concrete structures by means of post-installed anchors. Despite their widespread use, very little is known about the behavior of post-installed anchors when used in a system and loaded during an earthquake. The study presented in this paper was conducted to investigate the seismic performance of suspended model non-structural components connected by post-installed anchors to a concrete slab. The concrete slab was mounted in a special loading rig on a shake table and subjected to a series of floor motions simulating the acceleration histories at specific floor levels of typical reinforced concrete buildings of variable heights. Simultaneously, the anchors supporting the component were set in predefined cracks, which opened and closed according to pre-calculated crack histories. This unique test setup allowed evaluation of the performance of anchors and attached components under realistic boundary and loading conditions.

[1]  Philipp Mahrenholtz Experimental performance and recommendations for qualification of post-installed anchors for seismic applications , 2012 .

[2]  Rolf Eligehausen,et al.  Behavior of fasteners loaded in tension in cracked reinforced concrete , 1995 .

[3]  Michael J. Griffin,et al.  Nonstructural Seismic Performance for Facilities in Seismic Regions: Is the Expected Earthquake Performance Really Being Achieved? , 2009 .

[4]  Edward Cohen,et al.  Minimum Design Loads for Buildings and Other Structures , 1990 .

[5]  Matthew S. Hoehler Behavior and testing of fastenings to concrete for use in seismic applications , 2006 .

[6]  Tara C. Hutchinson,et al.  Cyclic Load Protocol for Anchored Nonstructural Components and Systems , 2013 .

[7]  Rolf Eligehausen,et al.  Shake Table Tests on Suspended Nonstructural Components Anchored in Cyclically Cracked Concrete , 2014 .

[8]  Andreas J. Kappos,et al.  Earthquake-resistant concrete structures , 1996 .

[9]  Tara C. Hutchinson,et al.  Crack Protocols for Anchored Components and Systems , 2013 .

[10]  T. Hutchinson,et al.  SEISMIC DISPLACEMENT BEHAVIOR OF ANCHORS CONNECTING NONSTRUCTURAL COMPONENTS TO CYCLING CRACKED CONCRETE , 2014 .

[11]  Anil K. Chopra,et al.  Dynamics of Structures: Theory and Applications to Earthquake Engineering , 1995 .

[12]  Charles C. Thiel,et al.  Improving Measures to Reduce Earthquake Casualties , 1992 .

[13]  Jack P. Moehle,et al.  "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318-11) AND COMMENTARY" , 2011 .

[14]  Giovanni Muciaccia,et al.  EXPERIMENTAL INVESTIGATION ON POST-INSTALLED METAL ANCHORS SUBJECTED TO SEISMIC LOADING IN R/C MEMBERS , 2009 .

[15]  Matthew S. Hoehler,et al.  Ceiling Anchorage Loads during Shake Table Tests of a Full-Scale Five-Story Building , 2012 .

[16]  Matthew S. Hoehler,et al.  Performance of Suspended Pipes and Their Anchorages During Shake Table Testing of a Seven-Story Building , 2009 .

[17]  Shahram Taghavi,et al.  Response assessment of nonstructural building elements , 2003 .

[18]  Gilberto Mosqueda,et al.  Performance of Nonstructural Components during the 27 February 2010 Chile Earthquake , 2012 .