Efficacy and biocompatibility of a photopolymerized, synthetic, absorbable hydrogel as a dural sealant in a canine craniotomy model.

OBJECT A canine craniotomy model was used to evaluate the dural sealing efficacy and biocompatibility of a novel, synthetic, bioresorbable hydrogel. METHODS Bilateral craniotomies were performed in 24 dogs assigned to six survival periods. In each animal a parasagittal durotomy was created and then repaired. At the treatment sites the hydrogel sealant was applied over the dural repair and photopolymerized. The repair was tested for leaks to 20 cm H2O by using a Valsalva maneuver. At the control sites the incisions were sutured and tested for leaks only. After uneventful survival periods, the leak test was repeated in three of the four animals in each group. Bone-dura adhesion was evaluated, after which the dura and underlying brain were removed, fixed, and examined histologically. En bloc histological investigation was performed on a specimen obtained from the fourth animal in each group. Over a 56-day period, 18 treated sites were tested for leaks. A leak was detected at a site remote from that of the repair in one animal; this was excluded from analysis. Thus 17 of 17 treated sites remained free of leaks. On the control side of one animal, there was a leak from a new dural tear at the cranial end of the durotomy, which occurred when the bone flap was removed. This site was also excluded from analysis. Eleven of 17 leak-tested control sites remained free of leaks over the study period. Bone-dura adhesions occurred in 15 of 19 control sites and had a mean adhesion score of 1.37 (range 0-4), whereas adhesions occurred in 10 of 19 treated sites with a mean adhesion score of 0.84 (range 0-3). No cortical reaction was noted. CONCLUSIONS This novel hydrogel sealant is efficacious in sealing dural repair sites measuring up to 2 mm. Healing of the underlying dura is not compromised and exposed cortical tissue is not altered histologically.

[1]  B. Rozdilsky,et al.  The role of neomembranes in formation of hematoma around Silastic dura substitute. Case report. , 1983, Journal of neurosurgery.

[2]  R. Janssen,et al.  Discussion: Creutzfeldt-Jakob Disease From Allogeneic Dura: A Review of Risks and Safety , 1991 .

[3]  J. Hubbell,et al.  Prevention of Postoperative Adhesions in the Rat by In Situ Photopolymerization of Bioresorbable Hydrogel Barriers , 1994, Obstetrics and gynecology.

[4]  J. Tew,et al.  Repair of spinal dural defects with vicryl (polyglactin 910) mesh. , 1989, Journal of spinal disorders.

[5]  K. M. Li,et al.  Study and clinical application of a porcine biomembrane for the repair of dural defects. , 1988, Journal of neurosurgery.

[6]  W. Abbott,et al.  Clinical results of lyophilized human cadaver dura transplantation. , 1971, Journal of neurosurgery.

[7]  P. Maurer,et al.  Vicryl (polyglactin 910) mesh as a dural substitute in the presence of pia arachnoid injury. , 1989, Journal of neurosurgery.

[8]  R. Marx,et al.  Creutzfeldt-Jakob disease from allogeneic dura: a review of risks and safety. , 1991, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[9]  M. Macfarlane,et al.  Lyophilised dura mater: experimental implantation and extended clinical neurosurgical use. , 1979, Journal of neurology, neurosurgery, and psychiatry.

[10]  W D Spotnitz,et al.  Neurosurgical applications of fibrin glue: augmentation of dural closure in 134 patients. , 1990, Neurosurgery.

[11]  W. E. Stern The surgical application of freeze-dried homologous dura mater. , 1958, Surgery, gynecology & obstetrics.

[12]  F. C. Usher,et al.  Lyophilized human dura mater as a dural substitute. , 1958, Journal of neurosurgery.

[13]  D. Sierra,et al.  The use of fibrin glue in intracranial procedures: Preliminary results , 1990, The Laryngoscope.

[14]  A. Laquérriere,et al.  Experimental evaluation of bilayered human collagen as a dural substitute. , 1993, Journal of neurosurgery.

[15]  T. Malinin,et al.  Freeze-dried allografts of dura mater - 20 years experience. , 1976, Transplantation proceedings.

[16]  P. Maurer,et al.  Vicryl (polyglactin 910) mesh as a dural substitute. , 1985, Journal of neurosurgery.

[17]  C. Bassett,et al.  Clinical use of freeze-dried human dura mater. , 1958, Journal of neurosurgery.

[18]  D. Simpson,et al.  Recurrent subarachnoid bleeding in association with dural substitute. Report of three cases. , 1984, Journal of neurosurgery.

[19]  J. Keller,et al.  Repair of spinal dural defects. An experimental study. , 1984, Journal of neurosurgery.

[20]  I. Feigin,et al.  Vinyon N as a dural substitute; an experimental study in the monkey. , 1955, Journal of neurosurgery.

[21]  L. Jian,et al.  Study and clinical application of a porcine biomembrane for the repair of dural defects. , 1988 .

[22]  F. Boop,et al.  Silastic duraplasty in pediatric patients. , 1991, Neurosurgery.

[23]  J. Anson Bovine Pericardium for Dural Grafts: Clinical Results in 35 Patients. , 1997, Neurosurgery.

[24]  F. D. Ingraham,et al.  THE USE OF FIBRIN FILM AS A DURAL SUBSTITUTE: AND IN THE PREVENTION OF MENINGOCEREBRAL ADHESIONS FURTHER STUDIES AND CLINICAL RESULTS , 1945 .

[25]  J. Guérin,et al.  Use of a biodegradable elastin-fibrin material, Neuroplast, as a dural substitute. , 1996, Biomaterials.

[26]  E. Benzel,et al.  Fascia Lata Graft as a Dural Substitute in Neurosurgery , 1990, Southern medical journal.

[27]  D. Barrow,et al.  Immune response in hosts with cadaveric dural grafts. Report of two cases. , 1994, Journal of neurosurgery.

[28]  Kristina J. Liu,et al.  Report of two cases , 1995 .

[29]  F. Silver,et al.  Use of collagen film as a dural substitute: preliminary animal studies. , 1991, Journal of biomedical materials research.

[30]  A. Cohen,et al.  Inflammatory reaction to synthetic dural substitute. Case report. , 1989, Journal of neurosurgery.

[31]  S. Yamagata,et al.  Clinical experience with expanded polytetrafluoroethylene sheet used as an artificial dura mater. , 1993, Neurologia medico-chirurgica.

[32]  D. Ducassou,et al.  Experimental evaluation of a collagen-coated vicryl mesh as a dural substitute. , 1992, Neurosurgery.

[33]  W Penfield,et al.  A New Method of preventing Adhesions. The Use of Amnioplastin after Craniotomy , 1940, British medical journal.

[34]  Major Robert C. L. Robertson,et al.  The Use of Tantalum Foil in the Subdural Space , 1945 .

[35]  R. Hayward,et al.  Haemorrhage associated with silastic dural substitute. , 1994, Journal of neurology, neurosurgery, and psychiatry.

[36]  J. J. Buckley,et al.  Report of Three Cases , 1962 .

[37]  R. Dryer,et al.  Cervical Spine Research Society Research Award: Evaluation of Dural Closure Techniques: Suture Methods, Fibrin Adhesive Sealant, and Cyanoacrylate Polymer , 1988, Spine.

[38]  P. Bergethon,et al.  A synthetic dural prosthesis constructed from hydroxyethylmethacrylate hydrogels. , 1995, Journal of neurosurgery.