In vivo physiological saline-infused hepatic vessel imaging using a two-crystal-interferometer-based phase-contrast X-ray technique.
暂无分享,去创建一个
Atsushi Momose | Kazuyuki Hyodo | Tohoru Takeda | Akio Yoneyama | A. Momose | A. Yoneyama | K. Hyodo | T. Takeda | Jin Wu | Jin Wu
[1] Ulrich Bonse,et al. X-ray computed microtomography (μCT) using synchrotron radiation (SR) , 1996 .
[2] A. Momose. Recent Advances in X-ray Phase Imaging , 2005 .
[3] S. Wilkins,et al. Phase-contrast imaging using polychromatic hard X-rays , 1996, Nature.
[4] Atsushi Momose,et al. Phase–contrast X–ray computed tomography for observing biological soft tissues , 1996, Nature Medicine.
[5] O. Bunk,et al. Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .
[6] E. Pisano,et al. Diffraction enhanced x-ray imaging. , 1997, Physics in medicine and biology.
[7] T Takeda,et al. Phase-contrast imaging with synchrotron X-rays for detecting cancer lesions. , 1995, Academic radiology.
[8] V. N. Ingal,et al. X-ray plane-wave topography observation of the phase contrast from a non-crystalline object , 1995 .
[9] Franz Pfeiffer,et al. X-ray phase imaging with a grating interferometer. , 2005, Optics express.
[10] Y. Kohmura,et al. Refraction-enhanced x-ray imaging of mouse lung using synchrotron radiation source. , 1999, Medical physics.
[11] F Busch,et al. X-ray microtomography (microCT) using phase contrast for the investigation of organic matter. , 1997, Journal of computer assisted tomography.
[12] Atsushi Momose,et al. Demonstration of phase-contrast X-ray computed tomography using an X-ray interferometer , 1995 .
[13] Kazuyuki Hyodo,et al. A phase-contrast X-ray imaging system—with a 60×30 mm field of view—based on a skew-symmetric two-crystal X-ray interferometer , 2004 .
[14] T Takeda,et al. Human carcinoma: early experience with phase-contrast X-ray CT with synchrotron radiation--comparative specimen study with optical microscopy. , 2000, Radiology.
[15] M. Takeda,et al. Fourier-transform method of fringe-pattern analysis for computer-based topography and interferometry , 1982 .
[16] Wu Jin,et al. Quantitative comparison of imaging performance of x-ray interferometric imaging and diffraction enhanced imaging. , 2008, Medical physics.
[17] Atsushi Momose,et al. Vessel Imaging by Interferometric Phase-Contrast X-Ray Technique , 2002, Circulation.
[18] U. Bonse,et al. AN X‐RAY INTERFEROMETER , 1965 .
[19] A. Momose,et al. Phase-contrast radiographs of nonstained rat cerebellar specimen. , 1995, Medical physics.
[20] E. Pisano,et al. Human breast cancer specimens: diffraction-enhanced imaging with histologic correlation--improved conspicuity of lesion detail compared with digital radiography. , 2000, Radiology.
[21] G. G. Stokes. "J." , 1890, The New Yale Book of Quotations.
[22] S. Wilkins,et al. Phase-contrast imaging of weakly absorbing materials using hard X-rays , 1995, Nature.
[23] Richard J. Fitzgerald,et al. Phase‐Sensitive X‐Ray Imaging , 2000 .
[24] A. Snigirev,et al. On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation , 1995 .
[25] T. Kozuka,et al. Adverse reactions to ionic and nonionic contrast media. A report from the Japanese Committee on the Safety of Contrast Media. , 1990, Radiology.
[26] E Castelli,et al. Mammography with synchrotron radiation: phase-detection techniques. , 2000, Radiology.
[27] Hong-Ming Lin,et al. Coherence-enhanced synchrotron radiology : refraction versus diffraction mechanisms. , 1999 .
[28] Atsushi Momose,et al. Demonstration of X-Ray Talbot Interferometry , 2003 .